SPECIFICATIONS
VTD-18N-TKA
• Rating: 35,000/50,000 Btu/Hr
• Type Gas: Natural Gas
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum - 5.0" W.C.*
• Shipping Weight: 48 lbs.
* For purpose of input adjustment.
VTD-24N-TKA
• Rating: 45,000/68,000 Btu/Hr
• Type Gas: Natural Gas
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum - 5.0" W.C.*
• Shipping Weight: 57 lbs.
* For purpose of input adjustment.
VTD-18P-TKA
• Rating: 35,000/50,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.*
• Shipping Weight: 48 lbs.
* For purpose of input adjustment.
VTD-24P-TKA
• Rating: 41,000/58,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Minimum Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.*
• Shipping Weight: 57 lbs.
* For purpose of input adjustment.
SERVICE hINTS
When Gas Pressure is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local natural gas supplier.
TEChNICAL SERVICE
You may have further questions about installa-
tion, operation, or troubleshooting. If so, con
-
tact DESA Heating, LLC at 1-866-672-6040.
When calling please have your model and
serial numbers of your heater ready.
You can also visit DESA Heating, LLC’s web
site at