www.desatech.com
116986-01F
16
WARNING: Burner will come
on automatically within one min-
ute after pilot burner is lighted.
6. Press the buttons
and
at the same
time. A short acoustic signal confirms start
sequence has begun.
Further short acoustic signals (0.2 sec.,
1 Hz) indicate the ignition process until it
is completed and main gas flows. If pilot is
already lit, motor will turn on (max. flame
height) while buttons are pressed down. If
pilot does not light, see
Troubleshooting
,
page 21.
7. Press
to turn on main burner and
increase flame height. Press
to de-
crease flame height and shut off main
burner.
8. Short tapping of either button allows
incremental change in flame height.
9. Press OFF button to switch off main gas
and pilot gas.
10. To leave pilot lit and shut off burners only,
press
to decrease flame height and
shut off main burner.
FUNCTIONS OF
REMOTE CONTROL
Battery
• After the charged battery has been correctly
installed, the remote hand set is ready for
operations.
• Remove the battery if the remote handset
will not be used more than one year.
Changing Code
The control is radio frequency operated. A
code (chosen from among 4,000 available
codes) is preset for all valves, but can be
changed if required (15 additional codes avail-
able). Change DIP switch position. (The DIP
switch is located inside the hand held control
at the top of the battery compartment.) Then
press the receiver's reset button on the bottom
of the receiver module until you hear a second
(longer) signal. When pressing the
button
on the remote handset in the following 20 sec.,
the receiver learns the new code.
OPERATION
Continued
REMOTE LIGHTING
INSTRUCTIONS
WARNING:
• If fireplace has glass doors,
never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Make
sure there are no obstructions
across openings of fireplace.
• You must operate this heater
with a fireplace screen in
place. Make sure fireplace
screen is closed before run-
ning heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open damper or window to
vent smell. This will only last a
few hours.
CAUTION: A mild gas flash
within 10 seconds is normal
during shutdown of this heater.
Remain clear of the hearth area
for the entire shutdown process
to avoid possible injury.
1. STOP! Read the safety information,
page 15.
2. Make sure equipment shutoff valve is fully
open.
3. Turn motor knob clockwise
to the
OFF position.
4. Wait
five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information, column 1. If you
don’t smell gas, go to the next step.
5. Make sure ON/OFF switch is in "–" (ON)
position.