Carbon  Monoxide  Poisoning:

  Early  signs 

of carbon monoxide poisoning resemble the 
flu, with headaches, dizziness or nausea. If 
you have these signs, the fireplace may not 
be working properly. 

Get fresh air at once! 

Have  fireplace  serviced.  Some  people  are 
more affected by carbon monoxide than oth

-

ers. These include pregnant women, people 
with heart or lung disease or anemia, those 
under the influence of alcohol and those at 
high altitudes.

Natural and Propane/LP Gas:

 Natural and 

propane/LP gas are odorless. An odor-making 
agent is added to the gas. The odor helps you 
detect a gas leak. However, the odor added to 
the gas can fade. Gas may be present even 
though no odor exists.
Make  certain  you  read  and  understand  all 
warnings. Keep this manual for reference. It 
is your guide to safe and proper operation of 
this fireplace.

  WARNING:  Any  change  to 

this fireplace or it’s controls can 

be  dangerous.  Do  not  modify 

this fireplace under any circum

-

stances. Any parts removed for 

servicing must be replaced prior 

to operating fireplace.

 WARNING: Do not use a blow

-

er insert, heat exchanger insert 

or other accessory not approved 

for use with this fireplace.

  WARNING:  This  appliance 

is only for use with the type of 

gas indicated on the rating plate. 

This appliance is not convertible 

for use with other gases unless 

a certified kit is used.

SAFety

Continued

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable  material  on  or  near 

the appliance. Never place any 

objects on the appliance.

Do not use this fireplace to cook 

food or burn paper or other flam

-

mable material.

This fireplace reaches high tem

-

peratures.  Keep  children  and 

adults away from hot surface to 

avoid burns or clothing ignition. 

Fireplace  will  remain  hot  for  a 

time after shutdown. Allow sur

-

face to cool before touching.

Carefully supervise young chil

-

dren when they are in the room 

with fireplace.

Keep  the  area  around  your 

fireplace  clear  of  combustible 

materials,  gasoline  and  other 

flammable vapor or liquids. Do 

not  run  fireplace  where  these 

are used or stored.

Summary of Contents for DVF-36ANH-S

Page 1: ...llow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Direct vent FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL NATURAL Propane LP Gas Models Gas Mo...

Page 2: ...de poisoning DANGER Carbonmonoxide poisoning may lead to death This vented gas fireplace is a sealed combus tion gas fireplace designed for residential ap plications This fireplace must be installed with DESA Heating LLC vent pipe components and terminations This fireplace complies with the National Safety Standards and is listed and tested by OMNI Test Laboratories Inc to ANSI Z21 50 standard as ...

Page 3: ...cingmustbereplacedprior to operating fireplace WARNING Donotuseablow er insert heat exchanger insert orotheraccessorynotapproved for use with this fireplace WARNING This appliance is only for use with the type of gasindicatedontheratingplate Thisapplianceisnotconvertible for use with other gases unless a certified kit is used Safety Continued WARNING Donotallowfans toblowdirectlyintothefireplace A...

Page 4: ...may be needed due to excessive lint and dust from carpeting bedding material etc Turn off the gas valve and pilot light before cleaning fireplace Safety Continued 6 Have venting system inspected annually by a qualified service person If needed have venting system cleaned or repaired See Cleaning and Maintenance page 24 7 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Us...

Page 5: ... pipe installation is very important to allow for proper operation You must follow the venting instructions very carefully for either vertical or horizontal applications This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed Each time you turn on your fireplace you may notice some amount of condensation on the inside of t...

Page 6: ...ng the full width and depth of the fireplace see Figure 3 Your fireplace is designed to be used in zero clearance installations Wall or fram ing material can be placed directly against any exterior surface on back sides or top of your fireplace except where standoff spacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall ...

Page 7: ...l heating system you may run system s circulat ingblowerwhileusingfireplace This will help circulate the heat throughout the house Framing and finishing Figure 4 shows typical framing of this fireplace Figure 5 shows framing for corner installation All minimum clearances must be met If you are using a separate combustible man tel piece refer to Figure 6 for proper instal lation height You can inst...

Page 8: ... US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall extend a min...

Page 9: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector...

Page 10: ...e components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning appliance A direct vent appliance must have its own venting system DO NOT common vent this appliance These models are approved to be vented either horizontally through an outside wall or vertically through ...

Page 11: ...entations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Horizontal runs of vent must be sup ported every three feet Use wall straps for this purpose 3 Assemble desired combination of pipe and elbows to fireplace flue colla...

Page 12: ...iding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to vent cap see Figure 12 Figure 10 Installing Horizontal Vent Cap Noncombustible Exterior Wood Screw Vent Cap Figure 11 Installing Siding Standoff Combustible Exterior Wall Cut Siding Away to Fit Standoff Wood Screw Scre...

Page 13: ...erty damage or loss of life GROUND FLOOR INSTALLATION Recommended Applications Through the wall using round or square termination NOT FOR CORNER INSTALLATION Figure 14 Horizontal Termination Using One 90 Elbow Vertical Termination Installation Note Vertical restrictor must be installed in all vertical installations 1 Determine route your vertical venting will take If ceiling joists roof rafters or...

Page 14: ... materials Frame opening as shown in Figure 9 page 11 4 Connect a section of pipe and extend up through hole Note If an offset is needed to avoid obstructions you must support vent pipe every 3 feet Use wall straps for this pur pose see Figure 15 Whenever possible use 45 elbows instead of 90 elbows The 45 elbow offers less restriction to the flow of flue gases 5 Place flashing over pipe section s ...

Page 15: ...ion above 2000 feet you may need to decrease the input rating by changing the existing burner orifice to a smaller size Reduce input 4 for each 1000 feet above sea level Check with your local gas company for proper orifice size identification When installing this fireplace at an elevation above 4500 feet check with local authorities Parts list for venting kits and components DESA 5 8 Pipe Vent Kit...

Page 16: ... shutoff valve with 1 8 NPT tap is an acceptable al ternative to test gauge connection Purchase the CSA design certified equipment shutoff valve from your retailer For propane LP connection only the installer must supply an external regulator The exter nal regulator will reduce incoming gas pres sure You must reduce incoming gas pressure to between 11 and 14 of w c pressure If you do not reduce in...

Page 17: ...quid petroleum LP gas We recommend that you install a sediment trap drip leg in supply line as shown in Figure 19 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fir...

Page 18: ...uid to all joints Bubbles forming show a leak Correct all leaks at once 5 Reconnect fireplace and equipment shutoff valve to gas supply Check recon nected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 21 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas fireplace or opening main...

Page 19: ...removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING If fireplace has been running turn off fireplace Let cool before removing glass doors Figure 24 Removing Replacing Door Removing Glass Door If replacement of glass is necessary the entire frame assembly must be replaced Gloves must be worn when removing replacing glass door If glass is broken tape re...

Page 20: ...lockburnerportsorpilotportsbyoverlapping ember flakes in one area It is not necessary to use all ember material provided 5 Place scrap log pieces randomly behind grate as shown in Figure 28 on lava rock and around but not on burner ports 6 Place grate in front of logs as shown in Figure 28 Be sure grate is balanced so it does not fall or lean onto logs Grate does not attach to hearth assembly Figu...

Page 21: ...on fluid to joints Bubbles forming show a leak Correct leaks at once CAUTION The gas supply shall be shut off prior to discon necting the electrical power if any before proceeding with this installation CAUTION Use gloves when removing the log set burner modulefromyourfirebox Some metal edges may be sharp Use caution with log sets as logs are fragile 1 Remove glass door see page 19 2 Remove grate ...

Page 22: ...nder water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting instructions NOTICE Duringinitialoperation of new fireplace burning logs will give off a paper burning smell Orange flame will also be present Open damper or window to vent smell This will only last a few hours 1 S...

Page 23: ... pilot and main burners If appliance will not stay lit after several attempts follow instructions under To Turn Off Gas To Appliance and call your service technician or gas supplier Sensing Rod Pilot Burner Ignitor Figure 34 Pilot OPERATION Continued TO TURN OFF GAS TO APPLIANCE 1 Turn off safety shutoff switch 2 Turn off all electric power to appliance if service is to be performed 3 Remove cente...

Page 24: ...nt configuration is installed incorrectly flames will lift or ghost This can be danger ous Inspect flames after installation to ensure proper installation and performance Figure 36 shows a typical flame pattern If burner flame pattern differs from that de scribed turn fireplace off see To Turn Off Gas to Appliance page 23 see Troubleshooting page 26 Figure 36 Typical Flame Pattern Cleaning and Mai...

Page 25: ...lace see Replacement Parts page 35 for detail on ordering No substitutions may be made See Removing Replacing Glass Door page 19 for instructions for re placing glass doors Cleaning and Maintenance Continued WARNING Do not operate fireplace with glass door un latched removed cracked or broken Pilot and burners Remove material before cleaning burners and replace when cleaning is complete Burner and...

Page 26: ...youhavegas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after re peated attempts appliance does not light call for quali fied service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pilot line 6 Rep...

Page 27: ...roded 1 Check electrical connec tions 1 Clean and adjust pilot flame for maximum flame im pingement on thermopile 2 Have vent system inspect ed including termination cap Remove any restriction or obstruction 1 This is normal with most fireplaces If noise is ex cessive contact qualified service person 1 Problem will stop after a few hours of operation TROUBLESHOOTING Continued POSSIBLE CAUSE 1 Loos...

Page 28: ... blocked 3 Improper venting or exces sive blockage 4 Excessive amounts of em bers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glass soots Dark residue on logs or inside of fireplace REMEDY 1 Locate and correct all leaks see Checking Gas Con nections page 18 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locat...

Page 29: ...ce 56 DVF 42P S H S Rating 37 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 0 w c Minimum Inlet Supply Pressure 11 w c Maximum Inlet Supply Pressure 13 w c Front Orifice 56 Rear Orifice 55 DVF 36AN S H S Rating 33 500 Btu hr Gas Type Natural Gas Only Ignition Electronic Manifold Pressure 3 8 w c Minimum Inlet Supply Pressure 5 w c Maximum Inlet Supply Pressure 10...

Page 30: ... 30 Parts Models DVF 36 A NS S DVF 36 A NH S DVF 42 A NS S DVF 42 A NH S DVF 36PS S DVF 36PH S DVF 42PS S DVF 42PH S 1 2 3 8 32 32 33 36 32 42 8 9 10 11 17 22 25 26 27 7 4 5 12 16 18 19 20 29 31 30 23 24 28 21 13 14 15 6 34 35 36 ...

Page 31: ...mbly 42 NG High Altitude 1 7 123210 01 Grate 36 1 123210 02 Grate 42 1 8 122652 01 Door Latch 2 9 Firebox Leg 4 10 Firebox Bottom 1 11 121431 01 Gasket 36 1 111913 02 Gasket 42 1 12 122919 01 Draft Diverter 1 13 Air Exchange 1 14 5 Gasket 1 15 5 Inner Connector 1 16 A E Insulation 1 17 Firebox Surround 1 18 Firebox Top 1 19 Relief Assembly 2 20 Relief Bracket 4 21 Top Plenum 1 22 Rear Plenum 1 23 ...

Page 32: ...om 123163 01C 32 Parts Burner Assembly Models DVF 36 A NS S DVF 36 A NH S DVF 42 A NS S DVF 42NH S DVF 36PS S DVF 36PH S DVF 42PS S DVF 42PH S 8 15 1 2 3 4 5 7 24 6 9 4 5 10 16 14 12 13 17 25 13 11 18 19 22 23 20 21 ...

Page 33: ...1 1 15 111817 09 Flextube Dormont 3 8 Dia x 24 1 16 Pilot Bracket 1 17 122116 01 Dexen Valve NG 1 122117 01 Dexen Valve LP 1 123782 01 Dexen Valve NG High Altitude 3 8 1 18 112823 01 Brass T Fitting 3 8 1 19 122118 01 Control Module 1 20 122119 01 Battery Relay 1 21 122121 01 Battery Pack 1 22 122860 01 Valve Bracket 1 23 120066 01 MLCR Receiver 1 24 123577 01 Log Assembly 36 1 123577 02 Log Assem...

Page 34: ...42 1 123236 01 Left Refractory Herringbone 36 1 123140 01 Left Refractory Stacked 42 1 123237 01 Left Refractory Stacked 36 1 3 123136 02 Right Refractory Herringbone 42 1 123236 02 Right Refractory Herringbone 36 1 123140 02 Right Refractory Stacked 42 1 123237 02 Right Refractory Stacked 36 1 4 123139 02 Left Front Refractory 42 1 123238 02 Left Front Refractory 36 1 5 123138 01 Center Front Ref...

Page 35: ...ent part s call DESA Heating LLC at 1 866 672 6040 for referral information A list of authorized dealers can be found by visiting www desatech com When calling DESA Heating LLC have ready model and serial numbers of your heater the replacement part number Service Hints When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat ...

Page 36: ... DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not...

Reviews: