TB-3081

 Page 3 of 6

Clock Menu

Monitor Mode

Adjust the date and time settings. Press the Cursor 

button to advance the cursor, and press the Start / Stop 

button to increase the value.

Display Menu

Adjust the contrast of the LCD display (0 to 9). The 

default contrast setting is 5. Press the Start / Stop 

button to increase the value.

°C/°F Menu

Choose Celsius (° C) or Fahrenheit (° F) for the 

temperature unit of measurement. Press the Start / Stop 

button to toggle the setting.

Operation Modes

There are 6 operation modes available:

1. MONITOR

2. ZERO

3. NEW

4. VIEW

5. CLEAR

6. COM
Press the Left button to move to the previous mode.

Press the Right button to move to the next mode.

Press the Start / Stop button to enter the selected mode.

Press the Exit button to exit the selected mode.

Allows on-the-go measurements without saving any 

data.

Zero Mode

Zeros out the Body Voltage Meter.

New Mode

Records new graph.

View Mode

Views saved graphs.

Clear Mode

Deletes last or all saved graphs.

Test Equipment Depot - 800.517.8431 - 

5 Commonwealth Ave,

 Woburn, 

MA 01801 

 - TestEquipmentDepot.com 

Summary of Contents for TB-3081

Page 1: ...verifications shall occur The compliance verification plan shall document the test methods used for process monitoring and measurements If the organization uses different test methods to replace those of this standard the organization shall be able to show that the results achieved correlate with the referenced standards Where test methods are devised for testing items not covered in this standard...

Page 2: ...nto a PC H Ground Jack Common point ground for the meter Connect the included black ground cord here I Ground Touch Plate Touch to ground the operator prior to taking body voltage measurements Settings Mode Press and hold the Settings button for 1 second to enter the SETTINGS mode There are 4 menus available 1 V RANGE 2 CLOCK 3 DISPLAY 4 C F Press the Left button to move to the previous menu Press...

Page 3: ...top button to toggle the setting Operation Modes There are 6 operation modes available 1 MONITOR 2 ZERO 3 NEW 4 VIEW 5 CLEAR 6 COM Press the Left button to move to the previous mode Press the Right button to move to the next mode Press the Start Stop button to enter the selected mode Press the Exit button to exit the selected mode Allows on the go measurements without saving any data Zero Mode Zer...

Page 4: ...ccurate and stable measurements The sensor uses a vibrating element to perform measurements and the warm up period allows its mechanical assembly to stabilize An exclamation mark symbol on the display and an audible sound will alert the operator once warm up has been completed Figure 3 Setup of the Body Voltage Meter 3 Verify the Body Voltage Meter is zeroed by toggling to the MONITOR menu and rea...

Page 5: ...Voltage Meter to a PC using the included Black 8 Pin DIN to USB Cable 7 Toggle to COM mode on the Body Voltage Meter 8 Run WTManager1 3 3 9 Click on Datalogger 10 Click on Com Port select 11 Click on Port The COM selection for the Body Voltage Monitor will become visible 12 When selected the unit will be highlighted 13 Click OK Figure 5 Using the Body Voltage Monitor 4 To stop the test press the S...

Page 6: ... 1 4 x 5 1 Ø35 mm x 130 mm Weight meter with batteries 1 4 lbs 650 g Weight probe 0 6 lbs 0 27 kg Country of Origin Italy Importing Data into a PC 1 Click on the Datalogger option 2 Select Import Graph A progess bar will appear at the bottom of the screen 3 Data can either be saved or exported in Excel format Figure 9 Replacing the Batteries on the Body Voltage Meter Figure 8 Viewing the body volt...

Reviews: