background image

TB-6545

Page 2 of 2

NOTE:  The AC power cord MUST be disconnected before
the unit is disassembled for maintenance.  The emitter
electrodes should be cleaned using the alcohol cleaners
included or a swab wet with Isopropyl alcohol.  First, turn
the unit OFF and unplug the power cord.  Then remove the
back cover by disengaging the 4 screws on back.  After
cleaning the emitter electrodes, reattach the back cover
using the 4 screws.  Plug in the power cord and turn the
unit back ON.

The emitter electrodes should not require replacement
during the life of the unit with normal handling.
Replacement emitter electrodes can be ordered if
necessary.

Best practice would be to verify the balance of the unit with
a charge plate monitor after cleaning.

Neutralization (Decay) Times

The comparative efficiency of benchtop ionizers is
determined by a standard test published by the ESD
Association: Standard S3.1.  Typical positive and negative
decay times (from 1000 volts to 100 volts) measured using
this standard are shown below.  The performance of the
ionizer was measured with the unit positioned as shown,
with the fan speed on high, and without a filter.

Figure 2. Neutralization (Decay) Times

Note:  Reference ESD STM 3.1-2000.  The distance from
the 50680/50681 to the charge plate is 18".  (Readings are
typical and taken at maximum fan speed.)

Specifications

Air Flow

Three speed fans (125fpm -250fpm; 50-100cfm).

Balance

±10 volt, typical; ±20 volts maximum. 

(Temperature range: 65°F to 80°F, R.H.: 15% to 65%)

Chassis

White powder coated steel housing.

Dimensions

3.5" height x 6.5" width x 37" length.

Emitter Points

.050" diameter pure tungsten for improved mechanical
strength and ionization stability.  

Fuse

400mA slow blow.

High Voltage Power Supply

5.5 KV DC nominal.

Input Power

AC line power, internally selectable for 110/115 VAC-
50/60Hz or 220/230 VAC-50/60Hz.

Ion Emission

Steady state DC with sense feedback.

Mounting

Hanging apparatus attached to ceiling.

Ozone

Less than 0.05ppm

Weight

10 pounds

NOTE:  Unauthorized servicing or modifications to your
ionizer will void the product warranty and may create
dangerous conditions.  Servicing should be performed only
at the factory, or by a Desco EMIT approved technician.  

© 2006 DESCO INDUSTRIES INC.

Employee Owned

DESCO EMIT WEST

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EMIT EAST

- 90 Hudson Road, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • DescoEMIT.com 

Limited Warranty

Desco EMIT expressly warrants that for a period of five (5) years from the
date of purchase, Desco EMIT Overhead Ionizers will be free of defects in
material (parts) and workmanship (labor). Within the warranty period, a
credit for purchase of replacement Desco EMIT products, or, at Desco
EMIT's option, the product will be repaired or replaced free of charge. If
product credit is issued, the amount will be calculated by multiplying the
unused portion of the expected five year life times the original unit purchase
price. Call our Customer Service Department at 909-627-8178 (Chino, CA)
or 781-821-8370 (Canton, MA) for a Return Material Authorization (RMA)
and proper shipping instructions and address. Please include a copy of your
original packing slip, invoice, or other proof of date of purchase. Any unit
under warranty should be shipped prepaid to the Desco EMIT factory.
Warranty replacements will take approximately two weeks.

If your unit is out of warranty, call our Customer Service Department at 909-
627-8178 (Chino, CA) or 01892 665313 (Crowborough, U.K.) for a Return
Material Authorization (RMA) and proper shipping instructions and address.
Desco EMIT will quote repair charges necessary to bring your unit up to
factory standards.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL
OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED,
INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED.  The express
warranty will not apply to defects or damage due to accidents, neglect,
misuse, alterations, operator error, or failure to properly maintain, clean or
repair products.

Limit of Liability 

In no event will Desco EMIT or any seller be responsible or liable for any
injury, loss or damage, direct or consequential, arising out of the use of or
the inability to use the product.  Before using, users shall determine the
suitability of the product for their intended use, and users assume all risk
and liability whatsoever in connection therewith.

Reviews: