A.  Touchscreen Display:

 Displays the time, date, 

temperature, humidity, command prompts, test results 

and settings.

B.  Single-Wire Wrist Strap Jack:

 Connect the 

single-wire wrist cord here to test.
See “10mm Wrist Cord Adapter” on page 7 if using 

single-wire wrist cords with a 10mm snap termination. 

C.  Dual-Wire Wrist Strap Jack:

 Connect the dual-wire 

wrist cord here to test.

D.  Solid-State Test Switch:

 Place and hold your finger 

here to begin the test.

E.  Ethernet Jack:

 For manufacturer use only. Not to 

be used with a local area network (LAN).

F.  Foot Plate Jack:

 Connect one end of the foot plate 

cable here and the other end to the dual foot plate.

G  5VDC Power Jack:

 Connect the included power 

adapter here to power the Combo Tester X3+.

H.  Dual USB Ports:

 For manufacturer use only.

I.  Cable Tie Mount:

 Use the included zip ties to 

secure all cables and cords connected to the Combo 

Tester X3+.

J.  Power Switch:

 Slide the switch to the top position 

to turn ON the Combo Tester X3+. Slide the switch to 

the bottom position to turn OFF the Combo Tester X3+.

K.  Relay Terminal:

 Integrates with electronic door 

locks, lights, buzzers, etc. See “Relay Terminal” on 

page 8

 

for more information.

L.  Ground Terminal:

 Secure the tinned wire 

termination of the included ground cord to this terminal. 

Connect the ring terminal termination of the cord to 

equipment ground. This connection will remove any 

static charge from the user before the test.

NOTE: Failure to correctly ground the Combo Tester 

X3+ may result in damage not covered under warranty.

M.  ESD Glove Test Fixture Port:

 Used for connecting 

the EMIT 50755 ESD Glove Test Fixture. See 

TB-6586

 

for more information.

Installation

Hardware Setup

If the Combo Tester X3+ is located near a restroom, 

sink or other water source, operators will need to be 

instructed to thoroughly dry their hands before testing. 

Wet hands may cause inaccurate test results and 

damage to the tester.
1.  Connect the ground cord, foot plate cable, and 

power adapter to the Combo Tester X3+. 

2.  Route all cables through the U-shaped opening 

located at the bottom of the Combo Tester X3+ and 

secure them to the cable tie mount with the included 

zip tie. 

3.  Connect the ground cord’s ring terminal to a known 

ground point. Connect the foot plate cable to the 

foot plate. 

4.  Connect the power adapter to an appropriate power 

outlet, and power the Combo Tester X3+ by sliding 

its power switch to the ON position. The display will 

turn on, and the boot sequence will initiate. “Begin 

Footwear Test Wrist Optional” will display on the 

Combo Tester X3+ after the boot sequence has 

completed. The blue LEDs will continuously cycle 

around the test switch when the ESD tester is on 

standby. 

5.  Use the included screws and anchors to secure 

the mounting bracket to the desired location. The 

screws may be used in any of the four holes shown 

below. Be sure to locate the bracket where users 

can read the display and use the tester. 

Figure 3. Mounting holes on the Combo Tester X3+ 

mounting bracket

Summary of Contents for Combo Tester X3+

Page 1: ...t test signal increases test reliability Pairs with the EMIT 50755 ESD Glove Test Fixture to test operators that wear ESD gloves or finger cots per Compliance Verification required by ESD TR53 September 2019 Figure 1 Desco ASK 37525 Combo Tester X3 The factory test limits are set to Wrist Straps 750 kilohms and 10 megohms Footwear 750 kilohms and 35 megohms See page 5 for alternate test limit sett...

Page 2: ...mployee Owned DESCO WEST 3651 Walnut Avenue Chino CA 91710 909 627 8178 DESCO EAST One Colgate Way Canton MA 02021 1407 781 821 8370 Website Desco com Features and Components Figure 2 Combo Tester X3 features and components A B C D E F G H I J K L M ...

Page 3: ...terminal termination of the cord to equipment ground This connection will remove any static charge from the user before the test NOTE Failure to correctly ground the Combo Tester X3 may result in damage not covered under warranty M ESD Glove Test Fixture Port Used for connecting the EMIT 50755 ESD Glove Test Fixture See TB 6586 for more information Installation Hardware Setup If the Combo Tester X...

Page 4: ...bly into the single wire jack on the face of the Combo Tester X3 Be sure to clear the clip at the base of the plunger s shaft when inserting into the jack 6 Connect the Combo Tester X3 to the bracket Use the included thumbscrew to secure the tester as shown below Figure 4 Securing the Combo Tester X3 to the mounting bracket Figure 5 Use the EMIT 50416 Stand as a mounting alternative 2 The plunger ...

Page 5: ...50 Kilohms 7 5 x 105 HIGH Limit Resistance HIGH Limit Resistance 10 Megohms 1 0 x 107 10 Megohms 1 0 x 107 35 Megohms 3 5 x 107 35 Megohms 3 5 x 107 100 Megohms 1 0 x 108 1 Gigohm 1 0 x 109 Default Settings A dirty foot plate could result in a false pass when the footwear limit is set to 1 Gigohm Be sure to keep the foot plate clean with 99 isopropyl alcohol when using this setting This setting is...

Page 6: ...ill become solid to indicate that the test has been initiated Hold your finger down until the test results are displayed on the touchscreen If your finger is removed too early the tester s blue LEDs will blink three times to indicate that the test was not completed DO NOT touch any other metal while performing your test as this will affect your results 5 The relay terminal will activate if the def...

Page 7: ...r Power Input 100 240VAC 50 60 Hz Power Output 5VDC 3 0A Cable Length 5 ft 1 5 m Operating Temperature 70 F to 85 F 21 C to 30 C for 1 gigohm test limit 41 F to 85 F 5 C to 30 C for all other test limits Environmental Requirements Indoor use only at altitudes less than 6500 ft 2 km Maximum relative humidity of 80 up to 85 F 30 C decreasing linearly to 50 85 F 30 C Maximum relative humidity of 50 a...

Reviews: