Resistance Ranges

1 x 10

3

 to 1 x 10

13

 ohms @ 

10 Volts, complies with ANSI/

ESD S4.1
1 x 10

6

 to 1 x 10

13

 ohms @ 

100 Volts, complies with ANSI/

ESD S4.1

Accuracy

±1/2 decade

Power Supply

9V alkaline battery

Operating Temperature 41ºF to 85ºF (5ºC to 30ºC)
Environmental 

Requirements

Indoor use only at altitudes 

less than 6500 ft. (2 km)
Maximum relative humidity of 

80% up to 85°F (30°C) 

Meter Dimensions

4.5" x 2.8" x 2.1"

(11 cm x 7 cm x 5 cm)

Meter Weight

0.5 lbs (0.2 kg)

Carrying Case Kit 

Dimensions

9.5" x 12.0" x 3.5"

(24 cm x 30 cm x 9 cm)

Carrying Case Kit 

Weight

12.0 lbs (5.4 kg)

External Electrode

5 lbs (±2 oz), 2.5" in diameter 

complies with ANSI/ESD S4.1

Summary of Contents for 19784

Page 1: ...irements to be verified the measurement limits and the frequency at which those verifications shall occur The Compliance Verification Plan shall document the test methods and equipment used for process monitoring and measurements If the test methods used by the Organization differ from any of the standards referenced in the document then there must be a tailoring statement that is documented as pa...

Page 2: ...tage will automatically switch from 10V to 100V when set to AUTO Test voltage will stay at 10V HOLD when set to 10V Operation Compliance Verification Test Procedure Guideline The ESD Association lists test procedures and troubleshooting tips in Compliance Verification ESD TR53 NOTE The test kit can be used to measure RTG and RTT of shelves garments floor and cart worksurfaces using test procedures...

Page 3: ...d be a good starting point Per ANSI ESD S4 1 Clean the electrodes with a minimum 70 isopropanol water solu tion Make sure conductive pads are dry prior to use The Analog Surface Resistance Meter requires little maintenance and there are no user serviceable parts If your unit requires service beyond cleaning the electrodes or replacing the batteries please contact Desco Customer Service RECOMMENDED...

Page 4: ...3 to 1 x 1013 ohms 10 Volts complies with ANSI ESD S4 1 1 x 106 to 1 x 1013 ohms 100 Volts complies with ANSI ESD S4 1 Accuracy 1 2 decade Power Supply 9V alkaline battery Operating Temperature 41ºF to 85ºF 5ºC to 30ºC Environmental Requirements Indoor use only at altitudes less than 6500 ft 2 km Maximum relative humidity of 80 up to 85 F 30 C Meter Dimensions 4 5 x 2 8 x 2 1 11 cm x 7 cm x 5 cm M...

Reviews: