background image

TB-3033

 Page 2 of 5

© 2011 DESCO INDUSTRIES INC.

Employee Owned

Features and Components

GUN AND HOSE

E. Disposable Filter Release / Lock Button: 

Push down 

to release the disposable filter and hose assembly from 

the console.  This button should also click when properly 

attaching the disposable filter and hose assembly to the 

console.

F. Disposable Filter: 

Filters particles, oil and moisture from 

the incoming air supply.

Figure 2: Gun and hose features and components

A

C

D

E

B

Figure 3: Console features and components

A

B

C

D

E

F

A. Hanging Clip: 

Use to hang the gun on an apparatus.  

May also be used with the included S-Hook.

B. Status LED:

 Illuminates when the trigger is held down.  

Indicates when the gun is outputting ionized air.

C. Nozzle:

 Outputs ionized air when the trigger is held 

down.

D. Trigger: 

Hold down to output ionized air.

E. Filter Connection:

 Hold down the metal tab to attach or 

release the disposable filter.

CONSOLE

A. Power LED:

 Illuminates when the power is turned ON.

B. Power Switch: 

Turns the power ON or OFF.

C. Foot Switch Jack: 

Foot Switch Jack: Connect the 

optional foot switch item #

19592

 here. See Figure 4. 

D. Supply Connection:

 Use with the quick coupling to 

connect to an air supply.

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: 

Desco.com

Figure 4: 

19592

 optional foot switch should be 

connected to the ion gun console Letter C in Figure 3

Installation

COMPRESSED GAS REQUIREMENTS

NOTE: Failure to use clean dry air or nitrogen may result 

in damage to the Chargebuster Ion Gun that is not covered 

under the Limited Warranty.
The compressed gas supply must be clean dry air or 

nitrogen supplied by a delivery system that utilizes a 

refrigerated dryer or equivalent water removal to achieve a 

limit of about 550 ppm water vapor at 35°F (1.66°C) Dew 

Point.  To prevent particles from entering the console, a 2 

micron coalescing filter or better is recommended upstream 

of the gun console.  Note that the filter in the console 

collects small residual particles and aerosols and does not 

act as a primary filter.  The console filter is rated at 0.01 

micron for particulates and is effective down to 0.008 micron 

for aerosols.  
An adequate filter that can be recommended for the inlet 

of the Chargebuster Ion Gun would be a Finite Filter Grade 

10 Media Specification.  This provides a 95% coalescing 

efficiency for aerosols with a 0.7 micron (and greater) 

particle retention.  This removes gross amounts of particles, 

water and/or oil and aerosols.

A Grade 6 Media provides 99.98% efficiency when almost 

total removal of liquid aerosols and particles are required in 

all pressure ranges down to 0.01 microns.  Fine filters need 

to be changed more often.

MOUNTING THE CONSOLE

Plug one end of the included 10’ cable into the jack on the 

back of the console.  Plug the other end of the cable into the 

unplugged Wall Transformer.

Summary of Contents for 19590

Page 1: ...arge of 1000 V down to 100 V in less than one second at a distance of six inches 30 psi 0 2MPa inlet pressure Refer to the ESD Association ANSI ESD Standard STM3 1 for the test procedure The offset voltage balance is within 30 V of zero at a distance of six inches significantly less than the required limits of 50 volts per ANSI ESD S20 20 Necessary non conductors in the environment cannot lose the...

Page 2: ... Figure 4 19592 optional foot switch should be connected to the ion gun console Letter C in Figure 3 Installation COMPRESSED GAS REQUIREMENTS NOTE Failure to use clean dry air or nitrogen may result in damage to the Chargebuster Ion Gun that is not covered under the Limited Warranty The compressed gas supply must be clean dry air or nitrogen supplied by a delivery system that utilizes a refrigerat...

Page 3: ... the console directly to the gas supply pipe or attach it using a hose not supplied If necessary use a prefilter as defined in the COMPRESSED GAS REQUIREMENTS section of this technical bulletin IV If you would like to use the optional foot switch plug its cable to the jack located at the top of the console Operation NOTE Our recommendation is to set the pressure regulator on your air or nitrogen s...

Page 4: ...egins to look dirty I Turn power off at the console and disconnect the console from the gas supply II Hold down the disposable filter release button on the side of the console III Remove the hose and disposable filter from the console by pulling the textured rubber plug where the hose emerges from the console Rocking the plug back and forth can help loosen the filter Do not pull the hose itself IV...

Page 5: ...rranty call Customer Service at 909 627 8178 Chino CA or 781 821 8370 Canton MA for a Return Material Authorization RMA and proper shipping instructions and address Desco Charleswater will quote repair charges necessary to bring your unit up to factory standards Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHA...