Testing and Calibration

Test using a version of EOS/ESD STM3.1. Observe and record 

offset voltage (float voltage) in voltage, measure of discharge 

time for +1000volts to +100volts and -1000volts to -100volts in 

seconds.

Equipment and tools used:

  - Charged Plate Monitor (CPM)

  - Medium sizes insulative flat head screw driver

Set-up:

1.  Refer to EOS/ESD STM3.1, 6.4 Compresses gas ionizers -  

  guns and nozzles. Test should be performed on static   

  dissipative worksurface. Testing technician and worksurface  

  needs to be properly grounded.

2.  Refer to figure 14 - Test location for compressed gas - Guns or  

  nozzles on page 13. CPM needs to be 6” from the center of the  

  CPM plate to worksurface. Tip of air nozzle needs to be at 6”  

  away from surface of CPM plate.

Testing:

Lab environment should be at 75°F at +/-5°F, relative humidity at 

45% at +/-5% RH. Observe offset voltage for no less than 10sec 

before recording.

Adjustment

Adjustments to the offset voltage could be made by using an 

insulative flat head screw. Balancing pot is location on the side of 

controller, where the white plastic cap is covering it.

Specifications

Input Voltage:

 

  

19587

  

120 VAC, 50/60 Hz 

  

19588

 

220 VAC, 50/60 Hz

Amperage standby:  

<50 milliamps

Amperage in use: 

<400 milliamps

   

Fuse: 

2ea 1 amp, 5 x 20mm, fast acting

Power Usage: 

2.5 watts on, 25 watts in use

Power Cord:

  

19587

 

Cord set with IEC connector 

  

19588

 

Not included

Air Gun: 

Two-piece molded ABS

Hose Length: 

7 feet

Control Box:  

5 1/8”H x 6 3/8”W x 7 1/8”L

Weight:  

11 pounds

Air Usage:  

3.5 CFM @ 30 PSI

Recommended PSI: 

30 PSI to 100 PSI

Air fittings: 

1/4” OD tubing with 1/8” NPT    

   

with adjustable needle valve.

Health

There are no known health risks associated with our devices. The 

emitters work at about 4-6 kV and can create ozone, but there 

have been no significant measurement of ozone from our emitter 

sets, as all our existing units test well below the OSHA limit of 0.05 

ppm ozone.  For additional safety information, see “Dispelling an 

Old Myth” written by William Metz of Hewlett-Packard published in 

Evaluation Engineering

 magazine, September 2001.

•  Indoor use

•  Altitude up to 2000m

•  Temperature 5°C to 40°C

•  Maximum relative humidity 80% for temperatures up to   

  31°C decreasing linearly to 50% relative humidity at 40°C

•  Mains supply voltage fluctuations up to ±10% of the nominal  

  voltage

•  Transient overvoltages typically present on the mains supply

•  Applicable rated pollution degree is 2

•  Degree of ingress protection is IP10

Adjustment screw

© 2010 DESCO INDUSTRIES INC.

Employee Owned

MFG Specifications Recorded Values

Offset voltage 

(floating voltage) in 

voltage

+/-25 volts

Discharge time, 

+1000volts to 

+100volts in seconds

2 sec or less

Discharge time, 

-1000volts to 

-100volts in seconds

2 sec or less

Limited Warranty

Desco expressly warrants that for a period of one (1) year from the date of purchase, Desco 

Ionizers will be free of defects in material (parts) and workmanship (labor).  Within the warranty 

period, a unit will be tested, repaired or replaced at Desco’s option, free of charge. Call 

Customer Service at 909-627-8178 (Chino, CA) or 781-821-8370 (Canton, MA) for Return 

Material Authorization (RMA) and proper shipping instructions and address. You should 

include a copy of your original packing slip, invoice, or other proof of purchase date.  Any unit 

under warranty should be shipped prepaid to the Desco factory. Warranty repairs will take 

approximately two weeks.

If your unit is out of warranty, Desco will quote repair charges necessary to bring your unit 

to factory standards.  Call Customer Service at 909-627-8178 (Chino, CA) or 781-821-8370 

(Canton, MA) for a Return Material Authorization (RMA) and proper shipping instructions and 

address.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT 

WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED.  

The express warranty will not apply to defects or damage due to accidents, neglect, misuse, 

alterations, operator error, or failure to properly maintain, clean or repair products.

Limit of Liability

Electronic ionizers use high voltage corona discharge and should not be used in or near 

flammable or explosive environments. In no event will Desco or any seller be responsible or 

liable for any injury, loss or damage, direct or consequential, arising out of the use of or the 

inability to use the product.  Before using, users shall determine the suitability of the product for 

their intended use, and users assume all risk and liability whatsoever in connection therewith.

Figure 10. Balance Adjustment.

Summary of Contents for 19587

Page 1: ...rge control on conductors or people Reference IEC 61340 5 2 1 paragraph 5 2 9 The Ion Python Neutralizing Hand Gun is NIST calibrated They come equipped with universal IEC cord connectors Neutralizing Ion Python Hand Gun Operation and Maintenance NOTE These units are not recommended for continuous use IONIZER SELECTION ANSI ESD S20 20 paragraph 6 1 1 2 ESD Control Program Plan Guidance states The ...

Page 2: ...heory of Operation The Ion Python and Neutralizing Hand gun employ high voltage AC to create a balanced ion field AC systems utilize emitters that are switched rapidly between positive and negative high voltage usually at the power line frequency 50 60 Hz The emitter is located at the end of the nozzle This emitter pro duces large amounts of positive and negative ions which mix with the air supply...

Page 3: ...er to maintain the optimum performance of your unit the following maintenance procedures must be performed on a regular basis Make sure that the air supply is clean and free of contamination and moisture Drain compressor tank and filters periodically The filters may require draining several times daily depending on your compressed air system The fuse may be replaced by removing the power cord at t...

Page 4: ...emperature 5 C to 40 C Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Mains supply voltage fluctuations up to 10 of the nominal voltage Transient overvoltages typically present on the mains supply Applicable rated pollution degree is 2 Degree of ingress protection is IP10 Adjustment screw 2010 DESCO INDUSTRIES INC Employee Owned MFG Spe...

Page 5: ... 401 Building No 5 JiuGe Business Center Lane 2301 Yishan Rd Minhang District Shanghai China Sales Direct 86 21 6401 6692 Email amall ameya360 com QQ 800077892 Skype ameyasales1 ameyasales2 Customer Service Email service ameya360 com Partnership Tel 86 21 64016692 8333 Email mkt ameya360 com ...

Reviews: