background image

TB-2079

 February 2010 Page 1 of 4

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: 

Desco.com

TECHNICAL BULLETIN TB-2079

Made in America

Figure 1. Ion Python Hand Gun (Controller with Hose)

Description

The Desco Ion Python Neutralizing Hand Gun is a ready-to-use 

unit designed for use in applications and areas where static can 

create manufacturing or handling problems. These units quickly 

and effectively neutralize bulk static charges and aid in controlling 

contamination by dislodging dust and debris attracted by static 

electricity. Airflow may be easily adjusted from a gentle stream to 

a powerful blast. These units are designed for use in applications 

and areas where ElectroStatic Attraction contamination create 

manufacturing or handling problems (Ref: ESD Handbook 

TR 20.20 paragraph 5.3.6.5.2.4 Point of Use Ionization). The 

Ion Python meets or exceeds the recommended technical 

requirements of ANSI/ESD S20.20 tested in accordance with 

ANSI/ESD S3.1.

Ionizers are useful in preventing electrostatic charge generation, 

ElectroStatic Discharge, ElectroStatic Attraction, as well as 

preventing equipment latch-up and safety related shock. ANSI/

ESD S20.20 Paragraph 6.2.3.1 Protected Areas Requirement 

states: “Ionization or other charge mitigating techniques shall be 

used at the workstation to neutralize electrostatic fields on all 

process essential insulators if the electrostatic field is considered 

a threat.”  Ionization is used to neutralize charges on process 

necessary insulators and isolated semiconductors.  Some 

examples of process necessary insulators are: the PC board 

itself, plastic test stands, plastic housing where a PCB may 

be mounted, as well as computer monitor screens and regular 

cleaning wipes.  Examples of floating or isolated conductors are: 

loaded PCB mounted in a stand where the pins are not contacting 

the dissipative workstation.  Ionization is not effective on items that 

have large capacitance, like people and carts; however, ionizers 

should be considered as a method for charge neutralization in 

cases where grounding cannot be achieved.
Air ionization can neutralize the static charge on insulated and 

isolated objects by producing separate charges in the molecules 

of the gases of the surrounding air.  When an electrostatic charge 

is present on objects in the work environment, it will be neutralized 

by attracting opposite polarity charges from the ionized air.  Note 

that ionization systems should not be used as a primary means 

of charge control on conductors or people. (Reference: IEC 

61340-5-2:1 paragraph 5.2.9).
The Ion Python Neutralizing Hand Gun is NIST calibrated. They 

come equipped with universal IEC cord connectors.

Neutralizing Ion Python Hand Gun

Operation and Maintenance

NOTE: These units are not recommended for continuous use.

IONIZER SELECTION

ANSI/ESD S20.20 paragraph 6.1.1.2. ESD Control Program 

Plan Guidance states: “The Plan should include a listing of the 

specific type of ESD protective materials and equipment used 

in the Program.”  When selecting an ionizer life cycle costs 

should be considered including: equipment cost; installation 

cost; and operation and maintenance cost.

Air Requirements

Always supply the Ion Python Hand Gun with filtered, dry 

noncombustible gases, such as compressed shop air or nitrogen. 

(If nitrogen is used, the tip will need to be replaced and the unit 

recalibrated. This 

MUST

 be done by the factory. Contact customer 

service at 909-627-8178). If the air is not dry, damage to the 

equipment may result and the warranty will be voided. Dirty air 

can introduce moisture and oil, contaminating the units’ emitter 

assembly along with the materials to be cleaned or neutralized. 

Filters must therefore be used at all times upstream of the air 

nozzle. A water trap-type pre-filter should be used in conjunction 

with an oil coalescing-type filter. Also drain all moisture traps 

regularly to prevent moisture in the line. Several drainings per day 

may be necessary, especially in areas of high humidity. 
The Neutralizing Ion Python Hand Gun may be operated over a 

range of 30 PSI to 100 PSI. The specific pressure needed will 

depend upon the application. Pressures exceeding 100 PSI are 

not recommended since these higher pressures are detrimental 

to effective ion production. An air pressure setting of 60 PSI is 

recommended. Use the needle valve located on the back of the 

controller to properly adjust the air flow.

Air Supply Connection

Turn off air at regulator (or compressor).  Insert the brass male 

connector (1/4” tubing to 1/8” pipe thread) into an available port 

on the regulator. If all ports are being used, a “T” or “+” may be 

added to create more ports.  Connect the 1/4” tubing to the male 

connector on the needle valve on back side of the unit, following 

the instructions given below.

To connect tubing or filter to quick connect fitting:

Cut end of plastic tubing square and clean. Push against the collar 

with thumbnail. While holding collar in, push tubing into the fitting 

until it bottoms out completely.

 

To release tubing or filter from quick connect fitting:

Push against the collar with thumbnail. While holding collar in, 

push tubing inward slightly, then pull tubing out.

    MODEL        STYLE        VOLTAGE AC       IEC CORD

 

 

19587

 

Hand Gun 

120 

Yes

 

19588

 

Hand Gun 

220 

No

© 2010 DESCO INDUSTRIES INC.

Employee Owned

Summary of Contents for 19587

Page 1: ...rge control on conductors or people Reference IEC 61340 5 2 1 paragraph 5 2 9 The Ion Python Neutralizing Hand Gun is NIST calibrated They come equipped with universal IEC cord connectors Neutralizing Ion Python Hand Gun Operation and Maintenance NOTE These units are not recommended for continuous use IONIZER SELECTION ANSI ESD S20 20 paragraph 6 1 1 2 ESD Control Program Plan Guidance states The ...

Page 2: ...heory of Operation The Ion Python and Neutralizing Hand gun employ high voltage AC to create a balanced ion field AC systems utilize emitters that are switched rapidly between positive and negative high voltage usually at the power line frequency 50 60 Hz The emitter is located at the end of the nozzle This emitter pro duces large amounts of positive and negative ions which mix with the air supply...

Page 3: ...er to maintain the optimum performance of your unit the following maintenance procedures must be performed on a regular basis Make sure that the air supply is clean and free of contamination and moisture Drain compressor tank and filters periodically The filters may require draining several times daily depending on your compressed air system The fuse may be replaced by removing the power cord at t...

Page 4: ...emperature 5 C to 40 C Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Mains supply voltage fluctuations up to 10 of the nominal voltage Transient overvoltages typically present on the mains supply Applicable rated pollution degree is 2 Degree of ingress protection is IP10 Adjustment screw 2010 DESCO INDUSTRIES INC Employee Owned MFG Spe...

Page 5: ... 401 Building No 5 JiuGe Business Center Lane 2301 Yishan Rd Minhang District Shanghai China Sales Direct 86 21 6401 6692 Email amall ameya360 com QQ 800077892 Skype ameyasales1 ameyasales2 Customer Service Email service ameya360 com Partnership Tel 86 21 64016692 8333 Email mkt ameya360 com ...

Reviews: