3.  Align the two snaps underneath the Mini Monitor 

to the two snaps on the worksurface mat.  Apply 

downward force on the monitor once aligned to 

snap the Mini Monitor into place. 

4.  Locate an appropriate AC outlet nearby the Mini 

Monitor, and test it for proper wiring and grounding 

prior to use.  The Desco AC Outlet Analyzer or 

similar test equipment may be used to verify the 

outlet’s functionality.  Use item number 

98132

 for 

120VAC North American outlets and item number 

98131

 for 220VAC UK outlets. 

5.  Connect the power adapter to the power jack 

located on the top-side of the Mini Monitor.  Route 

the wire from the supply to the tested AC outlet, and 

plug it into the outlet.

Installation onto Micastat® Laminate

Materials Needed:

14244

 Micastat® Flush Mount Ground Inserts 

14242

 Micastat® Flush Mount Insert Tool 

09857

 10mm Socket and Rivet (100 per pack) 

2  8-32 Button Cap Screws
1.  Install the two flush mount ground inserts into the 

Micastat® laminate.  Space the inserts as shown in 

Figure 3. 

2.  Once the ground inserts are installed, remove the 

8-32 screws that were supplied with the kits. 

3.  Place 10mm snap sockets on top of the installed 

brass ground inserts. 

4.  Screw the 10mm snap sockets into place on the 

ground inserts using the 8-32 button cap screws. 

5.  Align the two snaps underneath the Mini Monitor 

to the two snaps on the Micastat® laminate.  Apply 

downward force on the monitor once aligned to 

snap the Mini Monitor into place. 

6.  Connect the power adapter to the power jack 

located on the top-side of the Mini Monitor.  Route 

the wire from the supply to a nearby AC outlet 

and plug it into the outlet.  Make sure the voltage 

and frequency match those listed on the power 

supply.  The Mini Monitor is now powered, and the 

Micastat® laminate is now grounded.

Operation

1.  Fit the wristband snugly onto the wrist. 
2.  Snap the wrist cord to the wristband. 
3.  Plug the wrist cord into the operator jack.  The 

green operator LED will illuminate.  This indicates 

that the operator is properly grounded. 

4.  If this does not happen, examine the wrist cord for 

continuity or damage and the wristband to ensure 

that it fits securely.  If you have dry skin, apply an 

approved dissipative hand lotion such as 

Menda 

Reztore™ ESD Hand Lotion

5.  When leaving the workstation, first touch the 

monitor's park snap.  The monitor's audible 

alarm will disable for 6 seconds.  Use this time to 

disconnect the wrist cord from the wristband and 

attach it to the park snap without sounding a false 

alarm. 

6.  Upon returning to the workstation and disconnecting 

the wrist cord from the park snap, the monitor will 

provide 6 seconds for the operator to reconnect the 

wrist cord to a worn wristband before sounding the 

monitor's alarm.

Push and 

Clinch Snaps

Worksurface Mat

Figure 4.  Connecting the Mini Monitor to the push and 

clinch snaps on a worksurface mat

Figure 5.  Using the Mini Monitor

Summary of Contents for 19239

Page 1: ... a sine wave that the monitor circuit compares to established patterns By monitoring the distortions or shape of the sine wave Wave Distortion Technology determines if the monitored circuit is complete the operator is in the circuit and the total equivalent DC resistance is within specifications Wave Distortion Technology produces a very fast alarm time 50 milliseconds and minimal false alarms ANS...

Page 2: ...ord from the wristband and attach it to the park snap or remove the banana plug from the jack Upon returning to the workstation and disconnecting the wrist cord from the park snap the operator has 6 seconds to reconnect the wrist cord to a worn wristband before activating the alarm E Monitored Operator Jack Insert the single wire wrist cord here to monitor the operator s connection to ground F 10m...

Page 3: ...s using the 8 32 button cap screws 5 Align the two snaps underneath the Mini Monitor to the two snaps on the Micastat laminate Apply downward force on the monitor once aligned to snap the Mini Monitor into place 6 Connect the power adapter to the power jack located on the top side of the Mini Monitor Route the wire from the supply to a nearby AC outlet and plug it into the outlet Make sure the vol...

Page 4: ...erified with standard DC test equipment The continuous monitor is an impedance sensing device and the limits are determined by the magnitude and angle of the impedance The worksurface mat must have a conductive layer such as Dual Layer Rubber or Dissipative 3 Layer Vinyl with conductive buried layers Desco workstation monitors are not recommended for use with homogeneous matting Calibration Freque...

Reviews: