background image

TB-6545 Page 2 of 2

The emitter electrodes should not require replacement 
during the life of the unit with normal handling.  
Replacement emitter electrodes can be ordered if 
necessary.

Best practice would be to verify the balance of the unit with 
a charge plate monitor after cleaning.

Neutralization (Decay) Times

The comparative efficiency of benchtop ionizers is 
determined by a standard test published by the ESD 
Association: Standard S3.1.  Typical positive and negative 
decay times (from 1000 volts to 100 volts) measured using 
this standard are shown below.  The performance of the 
ionizer was measured with the unit positioned as shown, 
with the fan speed on high, and without a filter.

Ion Emission

Steady state DC with sense feedback.

Mounting

Hanging apparatus attached to ceiling.

Ozone 

Less than 0.05ppm

Weight 

10 pounds

NOTE:

  Unauthorized servicing or modifications to your 

ionizer will void the product warranty and may create 
dangerous conditions.  Servicing should be performed only 
at the factory, or by a Desco EMIT approved technician.  

© 2009 DESCO INDUSTRIES INC.

Employee Owned

EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website: 

DescoEMIT.com

Limited Warranty

Desco EMIT expressly warrants that for a period of five (5) years from the 
date of purchase, Desco EMIT Overhead Ionizers will be free of defects 
in material (parts) and workmanship (labor). Within the warranty period, 
a credit for purchase of replacement Desco EMIT products, or, at Desco 
EMIT’s option, the product will be repaired or replaced free of charge. If 
product credit is issued, the amount will be calculated by multiplying the 
unused portion of the expected five year life times the original unit purchase 
price. Call our Customer Service Department at 909-627-8178 (Chino, CA) 
or 781-821-8370 (Canton, MA) for a Return Material Authorization (RMA) 
and proper shipping instructions and address. Please include a copy of 
your original packing slip, invoice, or other proof of date of purchase. Any 
unit under warranty should be shipped prepaid to the Desco EMIT factory. 
Warranty replacements will take approximately two weeks.

If your unit is out of warranty, call our Customer Service Department at 
909-627-8178 (Chino, CA) or 01892 665313 (Crowborough, U.K.) for a 
Return Material Authorization (RMA) and proper shipping instructions and 
address. Desco EMIT will quote repair charges necessary to bring your unit 
up to factory standards.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF 
ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, 
INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED.  The express 
warranty will not apply to defects or damage due to accidents, neglect, 
misuse, alterations, operator error, or failure to properly maintain, clean or 
repair products.

Limit of Liability 

In no event will Desco EMIT or any seller be responsible or liable for any 
injury, loss or damage, direct or consequential, arising out of the use of or 
the inability to use the product.  Before using, users shall deter mine the 
suitability of the product for their intended use, and users assume all risk 
and liability whatsoever in connection therewith.

Figure 2. Neutralization (Decay) Times

Note:  Reference ESD STM 3.1-2000.  The distance from 
the Chargebuster Overhead Ionizer to the charge plate 
is 18”.  (Readings are typical and taken at maximum fan 
speed.)

Specifications

Air Flow

Three speed fans (125fpm -250fpm; 50-100cfm).

Balance

±10 volt, typical; ±20 volts maximum. 

(Temperature range: 65°F to 80°F, R.H.: 15% to 65%)

Chassis

White powder coated steel housing.

Dimensions

3.5” H x 6.5” W x 37” L  (8.9cm H x 16.5cm W x 94.0cm L)

Emitter Points

.050” diameter pure tungsten for improved mechanical 
strength and ionization stability.  

Fuse

400mA slow blow.

High Voltage Power Supply

5.5 KV DC nominal.

Input Power

AC line power, internally selectable for 110/115 
VAC-50/60Hz or 220/230 VAC-50/60Hz.