TB-6545 Page 2 of 2
The emitter electrodes should not require replacement
during the life of the unit with normal handling.
Replacement emitter electrodes can be ordered if
necessary.
Best practice would be to verify the balance of the unit with
a charge plate monitor after cleaning.
Neutralization (Decay) Times
The comparative efficiency of benchtop ionizers is
determined by a standard test published by the ESD
Association: Standard S3.1. Typical positive and negative
decay times (from 1000 volts to 100 volts) measured using
this standard are shown below. The performance of the
ionizer was measured with the unit positioned as shown,
with the fan speed on high, and without a filter.
Ion Emission
Steady state DC with sense feedback.
Mounting
Hanging apparatus attached to ceiling.
Ozone
Less than 0.05ppm
Weight
10 pounds
NOTE:
Unauthorized servicing or modifications to your
ionizer will void the product warranty and may create
dangerous conditions. Servicing should be performed only
at the factory, or by a Desco EMIT approved technician.
© 2009 DESCO INDUSTRIES INC.
Employee Owned
EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website:
Limited Warranty
Desco EMIT expressly warrants that for a period of five (5) years from the
date of purchase, Desco EMIT Overhead Ionizers will be free of defects
in material (parts) and workmanship (labor). Within the warranty period,
a credit for purchase of replacement Desco EMIT products, or, at Desco
EMIT’s option, the product will be repaired or replaced free of charge. If
product credit is issued, the amount will be calculated by multiplying the
unused portion of the expected five year life times the original unit purchase
price. Call our Customer Service Department at 909-627-8178 (Chino, CA)
or 781-821-8370 (Canton, MA) for a Return Material Authorization (RMA)
and proper shipping instructions and address. Please include a copy of
your original packing slip, invoice, or other proof of date of purchase. Any
unit under warranty should be shipped prepaid to the Desco EMIT factory.
Warranty replacements will take approximately two weeks.
If your unit is out of warranty, call our Customer Service Department at
909-627-8178 (Chino, CA) or 01892 665313 (Crowborough, U.K.) for a
Return Material Authorization (RMA) and proper shipping instructions and
address. Desco EMIT will quote repair charges necessary to bring your unit
up to factory standards.
Warranty Exclusions
THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF
ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED,
INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express
warranty will not apply to defects or damage due to accidents, neglect,
misuse, alterations, operator error, or failure to properly maintain, clean or
repair products.
Limit of Liability
In no event will Desco EMIT or any seller be responsible or liable for any
injury, loss or damage, direct or consequential, arising out of the use of or
the inability to use the product. Before using, users shall deter mine the
suitability of the product for their intended use, and users assume all risk
and liability whatsoever in connection therewith.
Figure 2. Neutralization (Decay) Times
Note: Reference ESD STM 3.1-2000. The distance from
the Chargebuster Overhead Ionizer to the charge plate
is 18”. (Readings are typical and taken at maximum fan
speed.)
Specifications
Air Flow
Three speed fans (125fpm -250fpm; 50-100cfm).
Balance
±10 volt, typical; ±20 volts maximum.
(Temperature range: 65°F to 80°F, R.H.: 15% to 65%)
Chassis
White powder coated steel housing.
Dimensions
3.5” H x 6.5” W x 37” L (8.9cm H x 16.5cm W x 94.0cm L)
Emitter Points
.050” diameter pure tungsten for improved mechanical
strength and ionization stability.
Fuse
400mA slow blow.
High Voltage Power Supply
5.5 KV DC nominal.
Input Power
AC line power, internally selectable for 110/115
VAC-50/60Hz or 220/230 VAC-50/60Hz.