background image

111252-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

16

PARTS LISTS FOR VENTING KITS AND COMPO-
NENTS FOR V36 AND VV36 SERIES (CONT.)

Number Description

S-58

Vinyl Siding Standoff, Galvanized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing - For use with HTS-5

PARTS LISTS FOR VENTING KITS AND
COMPONENTS FOR VV361 SERIES
DESA (5/8") Pipe & Vent Kits

Number Description

01492

Horizontal Square Termination Kit

Includes: 45° Elbow (Through 5" Wall), Wall Firestop,
Horizontal Square Termination

01493

Basic Vertical Termination Kit

Includes: Vertical Termination, Adjustable Flashing,
Storm Collar

01491

Horizontal Round Termination Kit

Includes: Round Termination, Wall Firestop, and
45° Elbow (Through 5" Wall)

01497

12" Section Coaxial Pipe - Galvanized (4)

01498

18" Section Coaxial Pipe - Galvanized (4)

01499

24" Section Coaxial Pipe - Galvanized (4)

01500

36" Section Coaxial Pipe - Galvanized (4)

01501

48" Section Coaxial Pipe - Galvanized (4)

01513

6" Section Coaxial Pipe - Galvanized (4)

01606

Adjustable 17"-24" Section Coaxial Pipe -
Galvanized (4)

F8030

Adjustable 7"-12" Section Coaxial Pipe - Galvanized (6)

D1032

Adjustable 7"-12" Section Coaxial Pipe - Galvanized (1)

DESA Elbows

Number Description

01502

45° Elbow - Galvanized (4)

01503

90° Elbow - Galvanized (4)

DESA Terminations

Number Description

01494

Vertical Round Termination - Galvanized (1)

01495

Horizontal Round Termination - Galvanized (1)

01496

Horizontal Square Termination - Galvanized (1)

01798

Vertical Round High Wind Termination (1)

01800

Horizontal Square High Wind Termination (1)

01801

14" Snorkel Termination - Galvanized (1)

01802

36" Snorkel Termination - Galvanized (1)

DESA Venting Accessories

Number Description

01504

Firestop Plate (4)

01505

Adjustable Roof Flashing [0 - 8/12] - Galvanized (6)

VENTING INSTALLATION
INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Parts Lists for Venting Kits and Components for V36 and VV36 Series (Cont.)
Parts Lists for Venting Kits and Components for VV361 Model Series
Parts Lists for Venting Kits and Components for CHDV Model Series

PARTS LISTS FOR VENTING KITS AND
COMPONENTS  FOR CHDV MODEL SERIES
DESA (5/8") Pipe & Vent Kits

Number Description

SDHTSK-58

Horizontal Square Termination Kit

Includes: 45° Elbow (Through 5" Wall), Wall
Firestop, Horizontal Square Termination

SDHTBK-58

Basic Vertical Termination Kit

Includes: Vertical Termination, Adjustable Flash-
ing, Storm Collar

SDHTRK-58

Horizontal Round Termination Kit

Includes: Round Termination, Wall Firestop,
and 45° Elbow (Through 5" Wall)

SDP58-12

12" Section Coaxial Pipe - Galvanized (1)

SDP58-18

18" Section Coaxial Pipe - Galvanized (1)

SDP58-24

24" Section Coaxial Pipe - Galvanized (1)

SDP58-36

36" Section Coaxial Pipe - Galvanized (1)

SDP58-48

48" Section Coaxial Pipe - Galvanized (1)

SDP58-6

6" Section Coaxial Pipe - Galvanized (1)

SDAP58-1724 Adjustable 17"-24" Section Coaxial Pipe -

Galvanized (1)

SDAP58-712

Adjustable 7"-12" Section Coaxial Pipe -
Galvanized (1)

DESA Elbows

Number

Description

SDE58-45

45° Elbow - Galvanized (1)

SDE58-90

90° Elbow - Galvanized (1)

DESA Terminations

Number

Description

SDVT-58

Vertical Round Termination - Galvanized (1)

SDHT-58

Horizontal Round Termination - Galvanized (1)

SDHTS-58

Horizontal Square Termination - Galvanized (1)

SDVSWT-58

Vertical Round High Wind Termination (1)

SDHSWT-58

Horizontal Square High Wind Termination (1)

SDST14-58

14" Snorkel Termination - Galvanized (1)

SDST36-58

36" Snorkel Termination - Galvanized (1)

DESA Venting Accessories

Number

Description

SDFSP-58

Firestop Plate (1)

SDAF-58

Adjustable Roof Flashing [0 - 8/12] - Galvanized (1)

SDSC-58

Storm Collar - Galvanized (1)

SDWS-58

Wall Strap (1)

SDS-58

Combustible Siding Standoff - Galvanized (1)

SDSPF-58

Steep Pitch Flashing [9/12 - 12/12] - Galvanized (1)

SDWFS-58

Wall Firestop - Galvanized (1)

VR-58

Vertical Restrictor - Galvanized (1)

01506

Steep Pitch Flashing 9/12 to 12/12 - Galvanized (6)

01507

Storm Collar - Galvanized (4)

01508

Wall Strap (4)

01514

Combustible Siding Standoff - Galvanized (1)

01607

Wall Firestop - Galvanized (4)

VR-58

Vertical Restrictor - Galvanized

Summary of Contents for VV36NA1 SERIES

Page 1: ...ppliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING If the information in this...

Page 2: ...nting system Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated connected a...

Page 3: ...fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nameplate 14 This appli...

Page 4: ...ocation for your fireplace and termination cap When deciding the location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel bur...

Page 5: ...ight above the fireplace Note Noncombustible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with y...

Page 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Page 7: ...tic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore attempting installa...

Page 8: ...slots on the male ends of adjacent pipes Push pipe sections together and twist one section clockwise approxi mately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal ru...

Page 9: ...standoff Bolt the vent cap to the stand off Apply non hardening mastic around outside edge of stand off Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exteri...

Page 10: ...l Horizontal Termination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screws High Wind Termination Apply Mastic to Outside Edge of Standoff Exterior Wall with Vinyl Siding 10...

Page 11: ...l rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on the exterior o...

Page 12: ...ce Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max Figure 17 Horizontal T...

Page 13: ...above is a room install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow conn...

Page 14: ...Elbow Vertical V Horizontal H 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Figure 22 Vertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown Note...

Page 15: ...nstallation Parts Lists for Venting Kits and Components for V36 and VV36 Series PARTS LISTS FOR VENTING KITS AND COMPONENTS FOR V36 AND VV36 SERIES DESA 5 8 Pipe Vent Kits Number Description P58 6 6 S...

Page 16: ...and Components for V36 and VV36 Series Cont Parts Lists for Venting Kits and Components for VV361 Model Series Parts Lists for Venting Kits and Components for CHDV Model Series PARTS LISTS FOR VENTING...

Page 17: ...in the switch bracket see Figure 26 Figure 25 Blower Model BK Magnetic Strips Exhaust Port Screw Green Ground Wire Spade Terminals Figure 26 Attaching Speed Control to Firebox Speed Control Control S...

Page 18: ...of the firebox outer wrapperwiththeexhaustportdirectedupwardandthethermodisc positioned up near the fireplace bottom The thermodisc must be oriented near the fireplace bottom as shown in Figure 28 in...

Page 19: ...tion must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 31 IMPORTANT Install ma...

Page 20: ...f the access holes on side of fireplace 3 Attach flexible gas line from gas supply to control valve see Figure 32 4 Check all gas connections for leaks See Checking Gas Connections Figure 32 Connectin...

Page 21: ...rminal Wires Battery Clip Figure 36 Connecting Wall Swith to Control Valve INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 1 Connect one terminal of 25 ft wire for the wall switch to the TPTH terminal on...

Page 22: ...ar gloves and tape the remaining fragments onto the frame 1 Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen rod assembly from the firebox Set...

Page 23: ...ce carefully remove logs lava rock and ember material 4 Remove three screws from deflector shield on the inside top of firebox Set shield and screws aside 5 Install rear brick panel first Rest bottom...

Page 24: ...nstructions for fireplace model numbers 1 Place log 1 base log onto pin on left front side of grate as shown in Figure 45 2 Restleftsideoflog 2 frontlog ontotopoflog 1 Placerightside oflogontosecondpi...

Page 25: ...ghtly and turn clockwise to OFF 5 Close lower louver panel Shutting Off Burners Only pilot stays lit You may shut off the burners and keep the pilot lit by doing one of the following 1 Turn gas contro...

Page 26: ...Fahrenheit Centigrademodedisplay carefullypressthe C Fmodebuttonwiththeendofapapercliporsimilarbluntobject Manual Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote contr...

Page 27: ...lame from the pilot burner must extend beyond both the thermocouple and thermopile If you pilot assembly does not meet these requirements turn fireplace off see To Turn Off Gas to Appliance page 25 se...

Page 28: ...emove if glass is hot Keep children and pets away from glass WARNING Donotoperatefireplacewiththeglass door removed cracked or broken WARNING Turn off fireplace and let cool before cleaning CAUTION Yo...

Page 29: ...y or partially clogged pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any me...

Page 30: ...burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Mainte nance page 28 or replace burner orifice 1 Adjust the log...

Page 31: ...ial OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark residue on logs or inside of firepl...

Page 32: ...TRATED PARTS BREAKDOWN Models V V36NA 1 V V36NSA 1 V V36NHA 1 V V36PA 1 V V36PSA 1 V V36PHA 1 and CHDV36NRA ILLUSTRATED PARTS BREAKDOWN MODELS V V36NA 1 V V36NSA 1 V V36NHA 1 V V36PA 1 V V36PSA 1 V V3...

Page 33: ...09082 01 109082 01 109082 01 109082 01 Heat Shield 1 10 ___ See Below See Below See Below Left Refractory Brick Panel 1 11 ___ See Below See Below See Below Rear Refractory Brick Panel 1 12 ___ See Be...

Page 34: ...4 4 3 2 5 6 7 8 9 10 11 12 13 14 15 16 17 1 21 19 20 18 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V V36NA 1 V V36NSA 1 V V36NHA 1 V V36PA 1 V V36PSA 1 V V36PHA 1 CHDV36NRA ILLUSTRATED PAR...

Page 35: ...Fitting 1 11 14554 Tubing Assembly 1 12 14500 Brass Fitting 1 13 14389 Millivolt Valve Natural Gas 1 14390 Millivolt Valve Propane LP Gas 1 14 14253 Flexible Gas Line 1 15 11107 Screw 10 32 x 1 4 PPH...

Page 36: ...feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer...

Page 37: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Page 38: ...111252 01B For more information visit www desatech com For more information visit www desatech com 38 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 39: ...ES LOUVER TRIM KIT Rolled Louvers Only Not Shown LT36B Rolled Louver Trim Kit Brushed Brass LT36P Rolled Louver Trim Kit Platinum LT36PB Rolled Louver Trim Kit Polished Brass DEFLECTION HOODS Not Show...

Page 40: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...