OPERATING FIREPLACE

OPERATING FIREPLACE

For Your Safety Read Before Lighting

Lighting Instructions

To Turn Off Gas To Appliance

Optional Remote Operation

Figure 49 - Turning  Equipment Shutoff Valve to the OFF Position

TO TURN OFF GAS

TO APPLIANCE

1

.

Turn off the wall switch.

2.

Turn off all electric power to the appliance if service is to
be performed.

3.

Open lower louver panel.

4.

Remove front hearth brick and control access panel.

5.

Turn equipment shutoff valve clockwise 

Clockwise

 to OFF.

Do not force.

6.

Close lower louver panel.

Figure 50 - Pilot

Sensing Rod

Pilot Burner

Ignitor

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information, above.

2.

Turn off all electric power to the appliance.

3.

Turn wall switch to the OFF position.

4.

Open lower louver panel.

5.

Turn equipment shutoff valve clockwise 

Clockwise

  to the OFF

position (see Figure 49). Do not force.

6.

Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information above. If you don’t smell
gas, go to the next step.

7.

Turn equipment shutoff valve counterclockwise 

C-clockwise

to the ON position. Do not force.

8.

Close lower louver panel.

9.

Turn on all electric power to the appliance.

10. Turn the wall switch to the ON position.

NOTICE: During initial operation of new heater, burn-
ing logs will give off a paper-burning smell. Orange
flame will also be present. Open damper or window to
vent smell. This will only last a few hours.

11. Visually locate the pilot. The ignitor should begin to spark and

the main burner should ignite once flame appears at pilot.
• If lighting the appliance for the first time each season, it

may take several attempts before the supply gas can reach
the pilot and main burners.

• If the appliance will not stay lit after several attempts,

follow the instructions 

To Turn Off Gas To Appliance

, be-

low, and call your service technician or gas supplier.

FOR YOUR SAFETY

READ BEFORE LIGHTING

 WARNING: If you do not follow these instructions

exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.

A. This appliance is equipped with an ignition device which

automatically lights the pilot. Do not try to light the pilot by
hand.

B. BEFORE LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire de-

partment.

C. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.

Equipment Shutoff Valve

OPTIONAL REMOTE

OPERATION

Note:

 The WRC receiver and hand-held remote control kit

must be purchased separately (see 

Accessories

, page 37). Follow

installation instructions on page 24.
1.

Turn equipment shutoff valve to ON position. You can now turn
the burner on and off with the hand-held remote control unit.

IMPORTANT:

 Be sure to press the ON/OFF buttons on the

hand-held remote control unit for up to 3 seconds to assure
proper operation.

2.

Press the ON/OFF button to turn the burner on and off.

Adjustment
Screw

Summary of Contents for VV36ENC1 SERIES

Page 1: ...t alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation consult a qualifi...

Page 2: ...em Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated connected and sealed...

Page 3: ...se this fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nameplate 14 Th...

Page 4: ...the location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not...

Page 5: ...combus tible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating system Do n...

Page 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Page 7: ...ng ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore at...

Page 8: ...e ends of adjacent pipes Push pipe sec tionstogetherandtwistonesectionclockwiseapproximatelyone quarterturnuntilthesectionsarefullylocked seeFigure8 Note Horizontal runs of vent must be supported ever...

Page 9: ...ff Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit flush against the exterio...

Page 10: ...rt with critical minimum and maximum dimensions which MUST be met IMPORTANT Remember that a horizontal run of venting must have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical...

Page 11: ...ntallythroughwall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations...

Page 12: ...NG INSTALLATION INSTRUCTIONS Installation Planning Cont HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal sys...

Page 13: ...oom install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow connections are f...

Page 14: ...Round High Wind Termination Shown Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure23 VerticalVentingCon...

Page 15: ...tion Shown Note Install restrictor into inner collar of fireplace as shown 45 Elbow PARTS LISTS FOR VENTING KITS AND COMPONENTS DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall P...

Page 16: ...Lists for Venting Kits and Components FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessory Model BK Installation Follow all instructions provided in the blower accessory kit 1 A...

Page 17: ...nnections securely 3 Place the blower against the lower rear wall of the firebox outer wrapperwiththeexhaustportdirectedupwardandthethermodisc positioned up near the fireplace bottom The thermodisc mu...

Page 18: ...ne LP Only Propane LP Supply Tank External Regulator Vent Pointing Down FIREPLACE INSTALLATION Continued FIREPLACE INSTALLATION Installing Optional Blower Accessory Cont Installing Gas Piping To Firep...

Page 19: ...e Nipple Tee Joint Sediment Trap Drip Leg Natural From Gas Meter 5 5 W C to 10 5 W C Pressure Propane LP From External Regulator 11 W C to 14 W C Pressure The CSA design certified equipment shutoff va...

Page 20: ...see Figure 34 for propane LPor Figure 35 for natural gas Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Fireplace Gas Conn...

Page 21: ...before removing glass door or louvers Spring Latch Removing Glass Door If replacement of glass is necessary the entire assembly glass and frame must be replaced If glass is broken wear gloves and tape...

Page 22: ...ing brick liner This brick liner kit is optional You may purchase brick liner from your local retailer or see Accessories page 37 CAUTION Always handle brick panels with two hands Do not force brick p...

Page 23: ...ont of firebox bottom in ar eas that are visible only It is not necessary to use all of the lava rock provided NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner will ca...

Page 24: ...dy to use 5 Close lower louver panel Figure 47 Installing the WRC Remote Receiver Fireplace Receptacle Remote Control Receiver Extension Cord Ignition Module Plug Figure 48 Installing Battery into Bac...

Page 25: ...flame appears at pilot If lighting the appliance for the first time each season it may take several attempts before the supply gas can reach the pilot and main burners If the appliance will not stay...

Page 26: ...and remove any dust dirt or other obstructions that will hinder the flow of air BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flame patterns will be different from unit to...

Page 27: ...be used CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotopera...

Page 28: ...and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pi lot line 6 Replace control...

Page 29: ...an material OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Slightsmokeorodorduringinitialoperation Gas odor even when control knob is in OFF position...

Page 30: ...ED PARTS BREAKDOWN Models V V36EN B V V36EP B VV36ENC1 VV36EPC1 VV36ENSC1 VV36EPSC1 VV36EPHC1 and VV36ENHC1 ILLUSTRATED PARTS BREAKDOWN MODELS V V36EN B V V36EP B VV36ENC1 VV36EPC1 VV36ENSC1 VV36EPSC1...

Page 31: ...01 109128 01 109128 01 109128 01 109028 01 Front Log Log 1 1 10 2 109129 01 109129 01 109129 01 109129 01 109129 01 Rear Log Log 2 1 10 3 109130 01 109130 01 109130 01 109130 01 109130 01 Crossover Lo...

Page 32: ...V V36EN B V V36EP B VV36ENC1 VV36EPC1 VV36ENSC1 VV36EPSC1 VV36EPHC1 and VV36ENHC1 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V36EN A V V36EN B V V36EP B VV36ENC1 VV36EPC1 VV36ENSC1 VV36EPS...

Page 33: ...racket 1 17 26827 Switch Bracket 1 18 11147 Screw 10 24 x 1 2 PPH Zinc 2 19 11186 Screw 8 32 x 1 Zinc 4 20 14115 Spade Tongue Connector 1 21 14120 Spade 1 4 Female Connector 4 22 14126 16 GA Green Wir...

Page 34: ...If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040...

Page 35: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Page 36: ...111253 01E For more information visit www desatech com For more information visit www desatech com 36 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 37: ...FPD36P Filligree Panel Kit Platinum FPD36PB Filligree Panel Kit Polished Brass LOUVER TRIM KIT Rolled Louvers Only Not Shown LT36B Rolled Louver Trim Kit Brushed Brass LT36P Rolled Louver Trim Kit Pla...

Page 38: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Reviews: