Desa VR32P Series Owner'S Operation And Installation Manual Download Page 36

LIMITED WARRANTy

DIRECT-VENT FIREPLACE

DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the 

product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty 

the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper 

operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through 

authorized retailers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement 

parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with 

the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as 

a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation 

and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS 

EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND 

ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 

TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA’S LIABILITY IS HEREBY LIMITED 

TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER 

INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, 

so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:

701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 410-9004
www.desatech.com

kEEP THIS WARRANT

WARRANTy INFORMATION

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make 

no other warranty, expressed or implied.

NOT A UPC

108661-01
Rev. F
03/06

108661 01

Summary of Contents for VR32P Series

Page 1: ...tly located manufactured mobile home where not prohibited by state or local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING Iftheinformationinthismanualis...

Page 2: ...tdoors To prevent performance problems do not use pro pane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any appliance do not touch any electric...

Page 3: ...res These are a few facts that can help you understand and enjoy your direct vent fireplace The venting system may be routed to the outside of your home in several ways It may vent through the roof ve...

Page 4: ...18 above top of louver opening When locating termination cap it is important to observe the minimum clearances shown in Figure 7 page 6 If recessing into a wall you can avoid extra framing by position...

Page 5: ...on Preparation Continued Figure 4 Framing Clearances for Installation Against an Exterior Wall 32 Models 36 Models A 323 8 361 8 B 345 8 411 4 C 19 231 2 C B A D E F G Top of Louver Opening 3 2 1 4 5...

Page 6: ...ve paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall extend a minimum of 24 61 c...

Page 7: ...ons will void the warranty Installation Precautions Wear gloves and safety glasses for protection Use extreme caution when using ladders or when on roof tops Be aware of electrical wiring locations in...

Page 8: ...re the vent will be terminated If the wall being penetrated is constructed of noncombustible material such as masonry block or concrete a 7 3 4 hole with zero clearance is acceptable see Figure 9 WARN...

Page 9: ...e overlap should be a minimum of 11 4 9 Slide wall firestop against interior wall surface and attach with screws provided See Figure 13 for horizontal termination details 10 Place fireplace into posit...

Page 10: ...ground to termination is possible Venting Installation instructions Continued Adjustable Pipe 12 Max Figure 14 Horizontal Termination Configuration for Square and Round Terminations 45 Elbow Wall Fir...

Page 11: ...l Termination Wall Firestop 90 Elbow 45 Elbow Figure 16 Snorkel Termination Configurations for Below Ground Installation 12 Minimum Adequate Drainage HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS...

Page 12: ...is an attic space or insulated area install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all...

Page 13: ...e 22 Vertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown Note Install restrictor into inner collar of fireplace as shown Venting with Two 90 Elbows Vertical V1...

Page 14: ...Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Horizon tal Termination 6 Pipe 90 Elbow Wall Firestop and 18 Screws HTK Horizontal Round Termination Kit Includes Round Termination Wall Fire...

Page 15: ...y turning knob fully counterclockwise before continuing 10 Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12 in front of the blower see Figu...

Page 16: ...blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up The blower speed can be adjusted by rotatingthec...

Page 17: ...ip leg in supply line as shown in Figure 31 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and fireplace Locate sediment trap drip leg...

Page 18: ...Pa 1 Close equipment shutoff valve see Figure 33 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LPgas fireplace or opening main gas valve located on or ne...

Page 19: ...wire from TH to TPTH on control valve see Figure 37 6 Connect wires from receiver to TH and TPTH to control valve see Figure 38 7 Replace the switch bracket Figure 36 Attaching Alkaline Battery to Re...

Page 20: ...ide 2 Lift up on latches to unlock There are two on top of firebox and two below firebox that hold glass door in place see Figure 41 3 While holding glass door to prevent it from falling and causing i...

Page 21: ...p of grate Make sure the notches in the bottom of the log fit over the grate see Figure 44 2 Rest log 2 large front log on the pins on the front part of the grate see Figure 45 1 2 Figure 44 Installin...

Page 22: ...derburner Placing lava rock on burner will cause performance problems 8 Pull ember material apart into pieces no larger than a dime Place these pieces loosely and sparingly directly onto the ex posed...

Page 23: ...Follow the gas supplier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repairit call a qualified...

Page 24: ...w locked If the fire is on it will be turned off automatically In the locked state the light will not light up when any button is pressed To Unlock press both buttons togetheron hand held remote contr...

Page 25: ...ontrol etc The keypad is locked in either on or off Press the POWER and LOCK buttons together to turn the unit on or off Operating optional GWMT1 Wall Mounted Thermostat WARNING Do not connect the the...

Page 26: ...osened Check mechanical supports such as wall straps for rigidity Cleaning and Maintenance WARNING Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcontrolareas burners and circulati...

Page 27: ...Dirty or partially clogged pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by an...

Page 28: ...from line Have gas line checked by local propane LP or natural gas company 3 Clean burner see Cleaning and Main tenance page 26 or replace burner orifice 1 Adjust the log set so that the flame does no...

Page 29: ...d 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark residue...

Page 30: ...burners will have delayed ignition fireplace will not produce specified heat propane LP gas supply might be low propane LP units only You may feel your gas pressure is too low If so contact your loca...

Page 31: ...lligree Louver Polished Brass ROLLED Louver Trim kit Not Shown LT32B 32 Brushed Brass LT32P 32 Platinum LT32PB 32 Polished Brass LT36B 36 Brushed Brass LT36P 36 Platinum LT36PB 36 Polished Brass Defle...

Page 32: ...MODELS V T32N V T32NB V T32NR V T32NRB V T32P V T32PB V T32PR V T32PRB AND CHDV32NR 6 7 21 18 19 10 13 2 11 20 8 22 2 22 6 22 4 22 5 22 3 22 1 1 14 9 12 17 3 15 4 16 5 16 9 3 9 2 9 1 9 13 9 14 9 18 9...

Page 33: ...ezo Ignitor 1 9 7 14500 Brass Fitting 2 9 8 14253 Flexible Connector 1 9 9 14511 Ignitor Bracket 1 9 10 14528 Brass Elbow Fitting 1 9 11 104506 25 Orifice Natural 1 14514 Orifice Propane LP 1 9 12 104...

Page 34: ...ELS V T36N V T36NB V T36NR V T36NRB V T36P V T36PB V T36PR V T36PRB AND CTDV36NR 6 7 21 18 19 10 13 2 11 20 8 12 23 1 23 4 23 3 23 6 23 5 23 2 1 14 9 22 17 3 15 4 16 5 16 9 10 9 12 9 4 9 5 9 9 9 7 9 3...

Page 35: ...179 Screw 10 24 x 1 4 Zinc 4 9 4 11237 Screw Trilab M4 x 8mm 1 9 5 14389 Millivolt Valve Natural 1 14390 Millivolt Valve Propane LP 1 9 6 14492 Piezo Ignitor 1 9 7 14500 Brass Fitting 2 9 8 14508 Flex...

Page 36: ...ted to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDE...