Proceed to secure appliance to prepared
framing at nailing flanges located at the
sides of the appliance as shown in Figure 11.

Figure 11 - Attaching Fireplace to Wall
Studs

VENTING
INSTALLATION

A 4" B-1 Type Gas Vent Pipe is a double
wall, unitized venting system (not supplied)
which must be installed during the rough
framing of the appliance. Any B-1 Type gas
vent system may be used for proper venting
as long as it is installed per the manufacturer's
recommendations.

This appliance has been supplied with a 4"
dia. starting collar for a snug fit. Slide B-1
vent pipe over starter pipe until fully seated.

Fasten this first section of "B" vent pipe by
running a 3/4" long sheet metal screw
through outer wall of pipe until secure. (see
Figure 12).

Figure 12 - Securing “B” Vent to Starter
Collar

The B-1 vent pipe must be properly termi-
nated per manufacturer's instructions.

Check with your B-1 Vent installation in-
structions regarding multiple venting into a
common flue.

IMPORTANT:

 Vent pipe MUST NOT ter-

minate in an attic space.

Minimum height for complete system (vent
termination and appliance) is 12 feet.

Maximum horizontal run of B-1 type vent
pipe can be no greater than 75% of total
vertical height of the vent.

PRE-INSTALLATION
PREPARATION

Continued

Secure B-Vent
to Starter
Collar Using
3/4" Long
Sheet Metal
Screw

Double Wall B-1
Type Vent
(Not Supplied)

Nailing
Flanges

Framing

Nails

Summary of Contents for Vanguard VGL450N

Page 1: ...ce Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your g...

Page 2: ...nstallation manual are in inches unless otherwise specified Figure 1 Appliance Dimensions Nailing Flange AGA and CGA Rating Labels Located Behind Access Panel Spacers 3 Sides J TH TP TP TH IN PILOT AD...

Page 3: ...ied service person The appli ance should be inspected before use and at least annually by a qualifiedserviceperson Morefre quent cleaning may be required duetoexcessivelintfromcarpet ing bedding mater...

Page 4: ...ING Typical framing is shown in Figures 8 through 10 depending on your particular installation If the appliance is to be installed directly on carpeting tile other than ceramic or any combustiblemater...

Page 5: ...il fully seated Fasten this first section of B vent pipe by running a 3 4 long sheet metal screw through outer wall of pipe until secure see Figure 12 Figure 12 Securing B Vent to Starter Collar The B...

Page 6: ...wall switch wires from TH and TH TP terminals on control valve see Figure 13 3 Install remote receiver unit onto mount ing bracket using the two plastic mount ing clips see Figure 14 4 Connect wires...

Page 7: ...W C 13 0 in W C For the purpose of input adjustment Figure17 1 8 PluggedTappingLocation INSTALLATION Continued Installing 9 Volt Battery in Hand Held Remote Control Unit 1 Remove battery cover on bac...

Page 8: ...e resistant to the action of Liquefied Petroleum LP or pro pane and should be applied lightly to ensure excess sealant does not enter the gas line GAS LINE HOOK UP A manual shut off valve must be incl...

Page 9: ...Turn gas control knob clockwise Clockwise to the OFF position 6 Wait five 5 minutes to clear out any gas Ifyousmellgas STOP Follow B in the safety information If you don t smell gas go to the next ste...

Page 10: ...ruc tions on pages 6 and 7 of this manual 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjust ment knob anywhere between HI and LO Slide the...

Page 11: ...BE ALERTED TOTHEHAZARDSOFHIGHSUR FACE TEMPERATURES AND TO STAY AWAY FROM THESE TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE...

Page 12: ...ch wires defective or too long 2 Pilot not generating sufficient millivoltage 1 Pilot flame may be too low causing safety pilot to drop out 1 Millivolt output on thermopile too high REMEDY 1 Check to...

Page 13: ...f page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner...

Page 14: ...hown Any B 1 type 4 dia gas vent pipe may be purchased from your local distributor or local hardware store PILOT ASSEMBLY Natural 20382 105740 01 LP 27085 105740 02 If in need of replacing have a qual...

Page 15: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 16: ...he responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND...