Desa VANGUARD LOGMATE FB32CB Owner'S Manual Download Page 20

116662 01

116662-01
Rev. G

09/08

NOT A UPC

DESA Heating, LLC

2701 Industrial Drive

Bowling Green, KY 42101
www.desatech.com

1-866-672-6040

WaRRaNTy

kEEp THIS WaRRaNTy

DESa HEaTINg, LLC LIMITED WaRRaNTIES

New Products

Standard Warranty:

 DESA Heating, LLC warrants this new product and any parts thereof to be free from 

defects in material and workmanship for a period of four (4) years from the date of first purchase from an 
authorized dealer provided the product has been installed, maintained and operated in accordance with 
DESA Heating, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from 
the date of first purchase.

Factory Reconditioned Products

Limited Warranty:

 DESA Heating, LLC warrants factory reconditioned products and any parts thereof 

to be free from defects in material and workmanship for 30 days from the date of first purchase from an 
authorized dealer provided the product has been installed, maintained and operated in accordance with 
DESA Heating, LLC’s warnings and instructions.

Terms Common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under 
this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, 
and only when installed by a qualified installer in accordance with all local codes and instructions furnished 
with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and 
an allowance for labor when provided by a DESA Heating, LLC Authorized Service Center or a provider 
approved by DESA Heating, LLC. Warranty parts must be obtained through authorized dealers of this prod

-

uct and/or DESA Heating, LLC who will provide original factory replacement parts. Failure to use original 
factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty 
repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the 
responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, 
improper installation, lack of proper maintenance, tampering, or alteration(s).
This is DESA Heating, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty 
excludes any and all other warranties, express or implied, written or verbal and limits the duration of any 
and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four 
(4) years on new products and 30 days on factory reconditioned products from the date of first purchase. 
DESA Heating, LLC makes no other warranties regarding this product.
DESA Heating, LLC’s liability is limited to the purchase price of the product, and DESA Heating, LLC shall 
not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or 
consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 
For information about this warranty contact:

Model (located on product or identification tag

) _____________________________

Serial No. (

located on product or identification tag

) __________________________

Date Purchased  __________________________

Keep receipt for warranty verification.

f i r e - p a r t s . c o m

Summary of Contents for VANGUARD LOGMATE FB32CB

Page 1: ...ted room heater for the minimum fireplace size requirement Do not install an appliance in this firebox unless this firebox meets the minimum dimensions required for the installation This firebox has b...

Page 2: ...elec tricalshockorcarbonmonoxide poisoning WARNING Any change to this firebox or its controls can be dangerous WARNING Donotallowfans to blow directly into the firebox Avoidanydraftsthatalterburner fl...

Page 3: ...properly See Air for Combustion and Ventilation page 5 6 Do not run firebox where flammable liquids or vapors are used or stored under dusty conditions 7 Do not use this firebox to cook food or burn...

Page 4: ...1 With utility knife cut the carton all the way around above the staples on the bottom tray Lift the carton off the firebox Remove packing Note The hood is located in the packing on the right hand si...

Page 5: ...m National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Un...

Page 6: ...mine the maximum Btu Hr the space can support _________ volume of space x 20 Maxi mum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can support...

Page 7: ...s or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts Youmustprovidetwopermanentopenings one within 12 of the ceiling and one within 12 of the floor Con...

Page 8: ...he wall This com bustible material must be 4 from the side of the fireplace opening see Figure 6 Figure 6 Minimum Clearance for Combustible to Wall Minimum 16 from Side Wall Example Figure 7 Minimum M...

Page 9: ...ted upward Align holes in top mounting tabs of blower with holes in wall of wrapper see Figure 9 Using 2 screws provided mount blower and tighten screws se curely Figure 8 Removing Screws from Firebox...

Page 10: ...der rear of firebrick lift firebrick up if necessary 12 Reattach firebox bottom using 4 screws removed in step 1 Note Discard remain ing hardware items 13 Install log set heater according to instal la...

Page 11: ...the manual shutoff valve should be accessible 5 Install and properly test gas log heater Follow installation instructions included with the vent free gas log heater that is being installed 6 Replace...

Page 12: ...n Firebox Installation Built in installation of this firebox involves installing firebox into a framed in enclosure This makes the front of firebox flush with wall If installing a mantel above the fir...

Page 13: ...Supply in log set owner s manual 6 Carefully insert firebox into rough opening 7 Attach firebox to wall studs using nails or wood screws through holes in nailing flange see Figure 20 8 Check all gas c...

Page 14: ...www desatech com 116662 01G 14 Parts Model FB32CB 5 16 16 15 16 17 4 6 1 16 7 16 14 21 13 18 10 8 20 12 19 9 3 2 3 2 16 11 18 18 fire parts com...

Page 15: ...ton Plug 1 5 103207 01 Outer Casing 1 6 Outer Shell Base 1 7 Firebox Wrapper 1 8 103297 01 Assembly Screen 2 9 103217 01CK Hood 1 10 103773 01 Front Assembly 1 11 Firebox Bottom 1 12 103809 01 Screen...

Page 16: ...www desatech com 116662 01G 16 PARTS Model FB32NCB 5 14 16 16 16 13 15 17 17 17 16 6 1 7 16 18 10 8 4 12 19 9 3 2 3 2 16 11 18 fire parts com...

Page 17: ...Front Assembly 1 11 Firebox Bottom 1 12 103809 01 Screen Rod 2 13 103816 01 Firebox Insulation 1 14 Firebox Support 2 15 101357 03 Outer Casing Top 1 16 M11084 26 Hex Head Screw 10 16 49 17 098194 02...

Page 18: ...urn the part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 for referral in...

Page 19: ...nted White Ultra Click n Brick Surround Corner CABINET Mantel with Base and black perimeter trim C32AU Unfinished Traditional Design C32AOS Light Oak Finish Traditional Design C32HS Dark Oak Finish Cl...

Page 20: ...by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use original fact...

Reviews: