background image

8

102590

!

CAUTION

Disconnect heater from propane supply tank(s).

STORAGE

1. Store propane tank(s) in safe manner. Follow all local codes. Always store

propane tanks outdoors.

2. Store in dry, clean, and safe place. Do not store hose/regulator assembly inside

heater combustion chamber.

3. When taking heater out of storage, always check inside of heater. Insects and

small animals may place foreign objects in heater. Keep inside of heater free
from combustible and foreign objects. Remove motor and other internal parts
if needed to remove foreign objects (see Service Procedures, page 10).

MAINTENANCE

1. Keep heater clean. Clean heater annually or as needed to remove dust and

debris. If heater is dirty or dusty, clean heater with a damp cloth.

2. Inspect heater before each use. Check connections for leaks. Apply mixture of

liquid soap and water to connections. Bubbles forming show a leak. Correct all
leaks at once.

3. Inspect hose/regulator assembly before each use. If hose is highly worn

or cut, replace.

4. Have heater inspected yearly by service person.
5. Keep inside of heater free from combustible and foreign objects. Remove

motor and other internal parts if needed to clean inside of heater (see Service
Procedures,
 page 10).

6. Clean fan every 500 hours of operation or as needed.

!

WARNING

Never service heater while it is plugged in, connected to
propane supply, operating, or hot. Severe burns and
electrical shock can occur.

P

i

e
z
o

Power

Cord

Motor

L1

L1

L2

L2

L2

L1

Solenoid

Valve

Thermal

Switch

L1

L2

Shell

Automatic

Control Valve

Thermocouple

Figure 6 - Wiring Diagram

WIRING

DIAGRAM

Summary of Contents for SH10E

Page 1: ...CTION HEATER OWNER S MANUAL IMPORTANT Read and understand this manual before assembling starting or servicing heater Improper use of heater can cause serious injury Keep this manual for future referen...

Page 2: ...signs of carbon monoxide poisoning resemble the u with headaches dizziness and or nausea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some...

Page 3: ...ane and electrical supply before moving or when not in use Use only the electrical voltage and frequency speci ed on model plate Use only the hose and regulator provided with the heater Inspect hose b...

Page 4: ...2 Cross Section Operational View THEORY OF OPERATION The Fuel System The hose regulator assembly attaches to the propane gas supply This provides fuel to the heater The Air System The motor turns the...

Page 5: ...1 1 1 1 INSTALLATION WARNING Review and understand the warnings in the Safety Informa tion Section pages 2 and 3 They are needed to safely oper ate this heater Follow all local codes when using this h...

Page 6: ...fr esh outside air openings for ventilation One opening should be near the floor the other opening near the ceiling Each ventilation opening must be at least 130 cm2 Provide proper fresh outside air v...

Page 7: ...n Automatic Control Valve Button WARNING Be sure motor and fan are running before pushing in automatic control valve button 5 Push in and hold automatic control valve button see Figure 5 Push piezo ig...

Page 8: ...rty or dusty clean heater with a damp cloth 2 Inspect heater before each use Check connections for leaks Apply mixture of liquid soap and water to connections Bubbles forming show a leak Correct all l...

Page 9: ...See Motor and Fan page 11 Clean heater See Maintenance page 8 Never service heater while it is plugged in connected to propane supply operating or hot Severe burns and electrical shock can occur TROUB...

Page 10: ...ver Remove fan guard from motor see Figure 9 6 Discard old motor 7 Attach fan guard to new motor with three nuts see Figure 9 Tighten nuts rmly 8 Place fan onto motor shaft of new motor IMPORTANT When...

Page 11: ...shell Attach ignitor wire to piezo ignitor 7 Set gap between ignitor electrode and target plate to 4 3 mm see Figure 13 8 Test for spark WARNING Make sure heater is disconnected from propane supply He...

Page 12: ...ide combustion cham ber see Figure 18 Adjust both thermocouple nuts until tip of thermocouple is 40mm from rear head 10 Tighten thermocouple nuts and confirm 40mm tip location 11 Thread the thermocoup...

Page 13: ...s on rear head see Figure 22 9 Replace star washers and nuts onto bolts 10 Recommended for accurate results Torque the nuts to 4 6 inch lbs 11 Place motor and fan guard into rear of heater shell see F...

Page 14: ...TRATED PARTS BREAKDOWN 1 2 3 2 4 6 7 8 8 9 11 21 22 35 36 23 25 44 33 34 19 20 11 11 40 32 21 5 10 39 24 16 12 13 14 15 Fan Nut Fan Rubber Washer Motor Motor Assembly 17 30 18 26 26 29 28 41 42 38 37...

Page 15: ...Supply Pressure min 2 bar Ventilation 260 cm2 Room Size 103 cubic meters Air Delivery Class Type A Temperature Range for Heater Operation 29 C to 29 C When running heater in temperatures above 29 C hi...

Page 16: ...rom misuse abuse negligence accidents lack of proper maintenance normalwear alteration modification tampering contaminatedfuels repairusingimproperparts orrepairbyanyoneother than an authorized dealer...

Reviews: