9
105342
OWNER’S MANUAL
SPECIFICATIONS
Output Rating (Btu/Hr)
65,000
85,000
100,000
Fuel Consumption
Gallons/Hour
0.7
.93
1.1
Pounds/Hour
3.0
3.9
4.6
Fuel
Propane Vapor Only
Supply Pressure To Regulator
Minimum (for purposes
of input adjustment)
10 psi
Maximum
Tank Pressure
Regulator Outlet Pressure
(Factory Preset)
Manifold Pressure
10" WC
Hot Air Output (CFM Approx)
475
Motor
3,200 RPM
Electric Input
120 V/60 Hz
Amperage
2.9
Ignition
Continuous
Ignitor Gap (Inches)
.13/.15
Weight (Pounds)
Heater
18
Shipping
24
Size - L x W x H (Inches)
Carton
28.25x12x17
Product
26.25x9x15.5
WIRING DIAGRAM
100,000 Btu/Hr Model
Black
Green
White
Motor
Ignitor
Orange
Blue
Blue
Auto Control
Valve
Thermocouple
1
2
3
4
5
6
8
7
Thermal Switch
Terminal Board
Blue
Black
Ignition
Control
White
Relay
Green
Green
Black
Black
White
White
Green
Power
Cord
REPLACEMENT
PARTS
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), either contact your nearest Parts
Central or call DESA International’s Tech-
nical Service Department at 1-800-323-
5190. When calling DESA International,
have ready:
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• purchase date
In most cases, we will ask you to return the
defective part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), either contact your nearest Parts
Central or call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. When calling DESA Interna-
tional, have ready:
• model number of your heater
• the replacement part number
WARNING: Use only original
replacement parts. This heater
must use design-specific parts.
Do not substitute or use generic
parts. Improper replacement
parts could cause serious or
fatal injuries. This will also pro-
tect your warranty coverage for
parts replaced under warranty.