21
Hot Surface Ignition Models Service Manual
8 Fuel Cap and Gasket Not Vented
Remove fuel cap and inspect the vent hole and gasket
to make sure the passage is open. Verify that only one
gasket has been installed. The fuel tank must be vented
properly for the fuel delivery system to operate correctly.
Nozzle Face
Nozzle
Nozzle
Seal
Nozzle
Adapter
Bracket
Air Line
Fitting
Fuel Line Fitting
Nozzle
Adapter
Combustion
Chamber
Nozzle/
Adapter
Assembly
35,000 - 165,000 Btu Models
Nozzle Face
Nozzle
Nozzle
Seal
Nozzle
Adapter
Air Line
Fitting
Fuel Line
Fitting
200,000 Btu Models
7 Check for Restricted Fuel Flow
35,000 to 165,000 Btu Models Remove air and fuel lines
from nozzle adapter. Remove nozzle adapter/nozzle from
bracket.
200,000 Btu Model Remove ignitor (do not strike or bend
element) from bracket. Place in a safe location. Remove
air and fuel lines from nozzle adapter. Remove two
bracket screws and remove bracket, nozzle adapter and
nozzle assembly from combustion chamber.
Using a 5/8" socket wrench, carefully remove the nozzle
from nozzle adapter. (Be extremely careful not to scratch
or score the face of the nozzle).
A. Seal Leak
Inspect nozzle seal or o-ring for damage. Replace if nec-
essary.
For replacement parts contact:
www.PartsFor.com