![Desa PORTABLE FORCED AIR HEATER Owner'S Manual Download Page 14](http://html.mh-extra.com/html/desa/portable-forced-air-heater/portable-forced-air-heater_owners-manual_2486060014.webp)
14
101911
7.
Check for debris in pump. If
debris is found, blow out with
compressed air.
8. Install insert and rotor.
9.
Check gap on rotor. Adjust to
.003"/.004" if needed (see
Figure 16).
Note:
Rotate rotor one full turn to
insure the gap is .003"/.004" at
tightest position. Adjust if needed.
(Pump Rotor, continued)
10. Install blades, pump plate, air
filters, and filter end cover.
11. Replace fan guard and upper
shell.
12. Adjust pump pressure (see page
12).
Note:
If rotor is still binding,
proceed as follows.
13. Perform steps 1 thru 6 (see page
13).
14. Place fine grade sandpaper (600
grit) on flat surface. Sand rotor
lightly in “figure 8” motion four
times (see Figure 17).
15. Reinstall insert and rotor.
16. Perform steps 10 thru 12 above.
Figure 17 - Sanding Rotor
.003"/.004" Gap
Measured With
Feeler Gauge
Gap Adjusting Screw
Gap Adjusting Screw
Blade
Rotor
Figure 16 - Gap Adjusting Screw Locations
Sandpaper
SPECIFICATIONS
Output Rating (Btu/Hr.)
165,000
Fuel
Use Only Kerosene or No. 1 Fuel Oil
Fuel Tank Capacity (U.S. Gal.)
13.5
Fuel Consumption (Gal. Per Hr.)
1.2
Electric Requirements
120 volt/60 hertz
Amperage (Normal Run)
4.5
Hot Air Output (CFM)
500
Motor RPM
3450
WIRING
DIAGRAM
White
Black
Blue
Green
Power Plug
120V 60HZ
Photocell
Spark Plug
Ignitor
Flame
Out
Control
B
Reset
Button
R
Red
Motor
Blue
White
White
White
White
Red
Red
Green
Terminal
Board
Red
Relay
Black