Desa PCDM-36VB Installation Instructions Manual Download Page 1

Parts included with this kit:

Part No.

Description

Quantity

114418-01

Instruction Sheet

1

108085-02

Pilot Orifice LP (30)

1

104506-20

Pan Burner Orifice LP (117, #56)

1

14544

Tube Burner Orifice LP (104, #59)

1

14488

Gas Valve Regulator LP

1

114355-39

Conversion Label, English

1

114356-39

Conversion Label, French

1

56060

Conversion Information Label

1

106739-01

Registration, Gas Conversion

1

Tools Required
• 7/8" Open End Wrench

or Adjustable Wrench

• 3/4" Open End Wrench

or Adjustable Wrench

• 11/16" Open End Wrench

or Adjustable Wrench

CONVERTING FROM NATURAL GAS TO PROPANE/LP GAS

For Use When Converting Model (V)V36N(-B)(C1) Series and CHDV36NR-C Series

This conversion kit must be installed by a qualified
service agency.

Read these instructions completely before installing this conversion kit.

Before proceeding, make sure the gas control valve is in the OFF
position, all electrical power to the appliance is off, and the fireplace
is cool to the touch.

 CAUTION: The gas supply shall be shut off prior to

disconnecting the electrical power before proceed-
ing with the conversion.

INSTALLATION INSTRUCTIONS
FOR PCDM-36VB CONVERSION KIT

Save this manual for future reference.

Save this manual for future reference.

For more information, visit www.desatech.com

For more information, visit www.desatech.com

• Torx T20 or Slotted Screwdriver
• 5/32" Allen Wrench
• #2 Short Phillips Screwdriver
• Thread Sealant

(Resistant to Propane/LP)

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling
both top end spring latches towards the center of the appliance until
they are disengaged from the locating holes (see Figure 1). Repeat
for bottom spring latches and pull the louvers outward. To install or
replace items removed, simply reverse the procedures above.

Figure 1 - Removing Louver Panel

Louver Panel

Spring Latch

ACCESSING FIREPLACE

The gas control valve and burner orifices are located under the firebox
floor of the appliance and are accessed by removing the lower louver
panel. The pilot orifice is located in the pilot burner and is accessed
by opening the glass door and removing the logs.

Lock

Unlock

Glass
Door

Figure 2 - Opening Glass Door

Latch

Opening Glass Door

1.

Remove screen assembly by pushing the rod either left or right
and then down and forward. Set assembly aside.

2.

Lift up on latches of door to unlock. There are two on top of
firebox and two below firebox that hold glass door in place (see
Figure 2).

3.

Remove log set from firebox. Refer to 

Installing Logs, Lava

Rock and Glowing Embers

 in owner’s manual.

Reviews: