15

105985

OWNER’S MANUAL

For more information, visit www.desatech.com

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Turn control knob clockwise  
to the OFF position.

2a. Set selector switch in the OFF position.

2b.

If Using Optional Hand-Held Re-
mote:

 Set selector switch in the OFF

position to keep from draining battery.

Shutting Off Burners Only (pilot
stays lit)

You may shut off the burners and keep
the pilot lit by doing one of the following:

1.

Turn control knob clockwise  
to the PILOT position.

2.

Use remote control manual OFF button.

3.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 6 under Light-
ing Instructions
, page 14.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 11, page 14.

1.

After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI
and LO. Slide the selector switch to
the REMOTE position. 

Note:

 The

burners may light if hand-held ON
button was on when remote selector
switch was last turned off. You can
now turn the burners on and off with
the hand-held remote control unit.

NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See 

Lighting

Instructions on page 14.

OPTIONAL REMOTE

OPERATION

OPERATING
HEATER

Continued

Thermostat Control Operation

(Optional GHRCT Only) The thermo-
stat control setting on the remote control
unit can be set to any comfort level be-
tween WARMER and COOLER. The
burners will turn on and off automati-
cally to maintain the comfort level you
select. The ideal comfort setting will vary
by household depending upon the amount
of space to be heated, the output of the
central heating system, etc.

Note:

 All remote control accessories must

be purchased separately (see Accessories,
page 23). Follow instructions included
with the remote control.

For wall thermostat operation, follow in-
struction supplied with thermostat acces-
sory GWMT1. For wall switch operation
follow instructions supplied with
GWMS2.

IMPORTANT: 

Be sure to press the

ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.

IMPORTANT:

 Do not leave the se-

lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the

burners on and off. When turning
burners off, the pilot will remain lit.

GHRCT Series Operation:

2b. Press the AUTO/ON/OFF button on

the hand-held remote control (see
Figure 28). The lights to the left of
the button will show AUTO, ON, or
OFF.
• In the ON mode, the burners will

ignite. The heater is in manual
mode when ON is lit.

Figure 27 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment
Knob for Remote Operation

Selector Switch in Remote Position (Optional Remote Control)

Control Knob in
On Position

Flame Adjustment Knob

ON
OFF
REMOTE

O

FF

PILO

T

O

N

L O

I H

Continued

Figure 28 - Thermostat Hand-Held Remote Control Unit Selections
(GHRCT Series Only)

Shows Temperature
Setting

Increases Room
Temperature in AUTO
Mode

Decreases Room
Temperature in AUTO
Mode

Turns Burners On or Off
and Allows You to
Choose the Auto Setting

The Log Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected

Summary of Contents for MSVFBNR Series

Page 1: ...ervice agency or the gas supplier WARNING This is an unvented gas fired heater Itusesair oxygen fromtheroomin whichitisinstalled Provisionsforadequate combustionandventilationairmustbepro vided Refer...

Page 2: ...aners or similar products turn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture 9 This heater needs fresh outs...

Page 3: ...outside venting There is no heat loss out a vent or up a chimney Heat is generated by realistic dancingyellowflames Thisheater is designed for vent free operation State and local codes in some areas p...

Page 4: ...ter vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or...

Page 5: ..._________Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actua...

Page 6: ...power vent Figure 2 Ventilation Air from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unc...

Page 7: ...This stove is a freestanding unit designed to set directly on the floor Do not place stove directly on carpeting vinyl tile or any com bustiblematerialotherthanwood Thestove mustsetonametalorwoodpane...

Page 8: ...ove see Figure 5 Use an adjustable wrench or a 10 mm socket Remove six 6 bolts and washers Keep bolts and washers to reattach back panel later 5 Remove all contents from inside stove cavity Contents i...

Page 9: ...see Fig ure 8 page 8 Use an adjustable wrench or a 12mm socket The catch bolt has two hex nuts attached to it see Figure 12 The top nut is a bolt stop and the bottom nut is for door leveling adjustmen...

Page 10: ...is seated into U shaped cutout in center of heater base Log will fit securely on base IMPORTANT Make sure log does not cover any burner ports and does not touch the stove cavity see Figure 16 9 Fasten...

Page 11: ...wellhead gas CAUTION Usepipejointseal ant that is resistant to liquid pe troleum LP gas INSTALLATION Continued CONNECTING TO GAS SUPPLY WARNING A qualified service personmustconnectheatertogas supply...

Page 12: ...ter Gas Connections 1 Open equipment shutoff valve see Fig ure 20 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from e...

Page 13: ...nient loca tion to mount your thermostat no out side wall IMPORTANT The wire must not exceed 25 feet in length The thermostat should be mounted 54 above the floor in a location where there is good air...

Page 14: ...e floor If you smell gas STOP Follow B in the safety in formation column 1 If you don t smell gas go to the next step 6 Press in and turn control knob coun terclockwise to the PILOT position Press in...

Page 15: ...he burners will turn on and off automati cally to maintain the comfort level you select The ideal comfort setting will vary byhouseholddependingupontheamount of space to be heated the output of the ce...

Page 16: ...til repairs are made light pilot with match To light pilot with match see Manual Light ing Procedure page 17 Figure 29 Control Knob and Ignitor Button Location Control Knob Ignitor Button Figure 30 Pi...

Page 17: ...gh 21 Figure 33 Correct Pilot Flame Pattern Figure 33 Incorrect Pilot Flame Pattern Thermocouple Pilot Burner Pilot Burner Thermocouple BURNERPRIMARYAIRHOLES Air is drawn into the burner through the h...

Page 18: ...Figure 35 3 Blow air through the ports slots and holes in the burner Figure 35 Injector Holder On Outlet Burner Tube 4 Check the injector holder located at the end of the burner tube again Remove any...

Page 19: ...s pressure is too low 3 Burner orifice diameter is too small 4 Thermopile leads disconnected or im properly connected 5 Burners will not come on in remote position REMEDY 1 Reconnect ignitor cable 2 F...

Page 20: ...atural gas company 3 Observe minimum installation clear ances see page 7 4 Clean burner see Cleaning and Mainte nance page 18 or replace burner orifice 1 Properly locate logs see Installing Gas Log He...

Page 21: ...ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REM...

Page 22: ...heater the replacement part number SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater will not produce specified heat When Gas Quality Is Bad...

Page 23: ...an turn the gas log heater on and off without ever leaving the comfort of your easy chair RECEIVER AND HAND HELD REMOTE CONTROL KIT GHRC SERIES For remote ready models Allows the gas log heater to be...

Page 24: ...EATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSVFBNR O F F P I L O T O N H I L O H I L O O F F P I L O T O N 17 17 18 19 24 15 14 16 13 12 12...

Page 25: ...80 01 Burner 1 9 099387 15 Pilot Tube Valve to regulator 1 10 103781 01 Gas Control Valve 1 11 103345 02 Lower Bracket 1 12 M11084 38 Screw 8 x 38 7 13 104383 02CK Painted Base Assy 1 14 098271 07 Ign...

Page 26: ...NT FREE NATURAL GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSVFBN 20 7 20 20 5 8 15 16 18 22 20 21 17 19 18 3 9 12 1 10 11 6 20 4...

Page 27: ...or 1 8 102798 01 Inlet Tube 1 9 102779 03 Outlet Burner Tube 1 10 099056 26 Burner Orifice Injector 1 11 102843 01 Burner Clip 1 12 102980 01 Burner 1 13 102568 07 Control Valve 1 14 098508 01 Valve R...

Page 28: ...RAL GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN SUN VALLEY STOVE MC SERIES Indicates Color Suffix Designation 1R 1C 1L 5 8 8 7 4 6...

Page 29: ...elain Enamel Almond 4 Total Per Stove 1 104175 14 One Leg Porcelain Enamel Green 4 Total Per Stove 1 104175 15 One Leg Porcelain Enamel Red 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 5...