background image

111922-01C

For more information, visit www.desatech.com

For more information, visit www.desatech.com

16

 CAUTION: Never touch the blower wheel while in

operation.

4.

Be certain that all wire terminals are securely attached to ter-
minals on blower motor and that the screw retaining the green
ground wire is tight.

5.

Mount speed control box to switch bracket by placing the plastic
control shaft forward through the opening in the switch bracket
(see Figure 26).

6.

While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise until it
is tight against front panel. Place control knob provided on shaft.

7.

Turn on power to duplex outlet if previously turned off per the
warning in column 1.

8.

Plug in blower power cord.
a.

If your firebox is installed as a freestanding unit with an
accessory mantel,

 determine whether the power cord will

exit the left side or the right side of the firebox. Route power
cord through exit hole and plug the power cord into a wall
receptacle near the firebox.

b.

If your firebox installation is recessed and/or pre-wired,

plug the power cord into the duplex outlet provided. Refer
to your firebox owner’s manual for instructions on wiring
the duplex outlet.

Figure 25 - Blower Model BK

Magnetic Strips

Exhaust
Port

Screw

Green
Ground Wire

Spade Terminals

Figure 26 - Attaching Speed Control to Firebox

Side View

Lower Firebox
Cavity

Blower
Location

FIREPLACE INSTALLATION

FIREPLACE INSTALLATION

Check Gas Type
Installing Optional Blower Accessory

Model BK Installation

Follow all instructions provided in the blower accessory kit.
1.

Attach the power cord to the blower motor by firmly pushing the
two female terminals at the end of the power cord onto the two
spade terminals on the blower motor (see Figure 25).

2.

Attach green ground wire from power cord to blower housing
using screw provided (see Figure 25). Tighten screws securely.

3.

Place the blower against the lower rear wall of the firebox outer
wrapper with the exhaust port directed upward. The blower
will fit inside the back opening and be held in position against
the back wall by the magnets (see Figure 25).

INSTALLING OPTIONAL BLOWER
ACCESSORY

NOTICE: If installing blower in an existing fireplace
with gas connections, shut off gas supply and dis-
connect heater from gas supply. Contact a qualified
service person to do this.

 WARNING: If there is a duplex electrical outlet

installed in the right side of the bottom of the fireplace
base area, be sure that the electrical power to the outlet
is turned off before proceeding with blower installation.
Failure to do this may result in serious injury.

Speed Control

Control
Shaft

Locknut

Control
Knob

Switch
Bracket

Blower
Plug-In

Duplex Outlet
(Located underneath
firebox floor against
lower right outside wall)

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If your
gas supply is not correct, do not install fireplace. See retailer where
you purchased the fireplace for proper fireplace according to your
gas type or to purchase gas conversion kit (see 

Accessories

, page 34).

9.

Check to make sure that the power cord is completely clear of the
blower wheel and that there are no other foreign objects in blower
wheel. Turn blower on and check for operation. Turn blower off
by turning knob fully counterclockwise before continuing.

Summary of Contents for K42EN Series

Page 1: ...n service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation consult a qualified in stall...

Page 2: ...liance is not convertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate propane LP supply tank s...

Page 3: ...This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Ca nadian Electrical C...

Page 4: ...he location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not lo...

Page 5: ...s tible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating system Do not in...

Page 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Page 7: ...ng ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore at...

Page 8: ...ctions together and twist one section clockwise approximately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three feet Use wall...

Page 9: ...sition the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit flush against the exterior fas...

Page 10: ...igure includes a chart with critical minimum and maximum dimensions which MUST be met IMPORTANT Rememberthatahorizontalrunofventingmust have a 1 4 rise for every 12 of run toward the termination Figur...

Page 11: ...throughwall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations requir...

Page 12: ...max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max 45 Elbow Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace Figu...

Page 13: ...oom install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow connections are f...

Page 14: ...wo90 Elbows Vertical Round High Wind Termination Shown VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination Cont Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5...

Page 15: ...Wall Pipe Galvanized PA58 712 Adjustable7 12 SectionDoubleWallPipe Galvanized FPA58 6 6 DuraventCollartoFMIPipeAdaptor 6 Collar Pipe Section DPA58 6 6 FMICollartoPipeDuraventAdaptor 6 Collar Pipe Sec...

Page 16: ...ructions provided in the blower accessory kit 1 Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the bl...

Page 17: ...e thermodisc must be oriented near the fireplace bottom as shown in Figure 28 in order to sense temperature and properly operate The blower will be held in position against the back wall by the magnet...

Page 18: ...External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator Vent Pointing Down FIREPLACE INSTALLATION Continued FIREPLACE INSTALLATION Installing Optional Blow...

Page 19: ...provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas supply to contro...

Page 20: ...ection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operating Fireplace pages 24 and 25 Check all other internal joints for leaks 6 Turn off fireplac...

Page 21: ...tch Cleaning Glass Door See Cleaning and Maintenance on page 26 Figure 38 Installing Rear Left and Right Brick Panels Rear Brick Panel INSTALLING BRICK LINER MODELS BL42DA SA BL42DHA SA WARNING If fir...

Page 22: ...ber Material Figure 44 Placing Ember Material on Burner 8 9 Figure 43 Installing Logs No 8 and No 9 WARNING The glass door must be securely in place before running this fireplace Do not run this firep...

Page 23: ...ttery by removing the insulat ing tab on the back of the handset see Figure 46 The battery is included pre installed 4 Once the battery is activated the unit is ready to use 5 Close lower louver panel...

Page 24: ...ars at pilot If lighting the appliance for the first time each season it may take several attempts before the supply gas can reach the pilot and main burners If the appliance will not stay lit after s...

Page 25: ...ove any dust dirt or other obstructions that will hinder the flow of air BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flame patterns will be different from unit to unit an...

Page 26: ...ed CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotoperatefire...

Page 27: ...e and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pi lot line 6 Replace contro...

Page 28: ...erial OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Slightsmokeorodorduringinitialoperation Gas odor even when control knob is in OFF position Gas o...

Page 29: ...CAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040 Whencalling pleasehaveyourmodeland serial n...

Page 30: ...rmation visit www desatech com 30 ILLUSTRATED PARTS BREAKDOWN Models V K42EN V K42ENH V K42EP V K42EPH ILLUSTRATED PARTS BREAKDOWN MODELS V K42EN V K42ENH V K42EP V K42EPH 6 7 20 17 18 13 2 12 19 8 1...

Page 31: ...4 108331 01 Top Louver Assembly 1 5 108331 02 BottomLouver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 02 Heat Shield 1 10 111925 01 Log Set 1 10 1 11193...

Page 32: ...visit www desatech com 32 ILLUSTRATED PARTS BREAKDOWN Models V K42EN V K42ENH V K42EP V K42EPH ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V K42EN V K42ENH V K42EP V K42EPH 7 9 8 12 12 6 1...

Page 33: ...02 Screw 8 32 x 3 8 PPH Zinc 2 8 108866 01 Pilot Natural Gas 1 108866 02 Pilot Propane LP Gas 1 9 111316 01 Pilot Bracket 1 10 111913 02 Burner Base Gasket 1 11 111310 02 Firebox Bottom 1 12 11165 Scr...

Page 34: ...s FPD42P Filligree Panel Kit Platinum FPD42PB Filligree Panel Kit Polished Brass LOUVER TRIM KIT Rolled Louvers Only Not Shown LT42B Rolled Louver Trim Kit Brushed Brass LT42P Rolled Louver Trim Kit P...

Page 35: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Page 36: ...111922 01C For more information visit www desatech com For more information visit www desatech com 36 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 37: ...___________________________________________________________ _______________________________________________________________________________________________ ____________________________________________...

Page 38: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Reviews: