www.desatech.com
21
121255-01A
SPECIFICATIONS
LCR18NT, HDR18NT
• Natural Gas
• 18,000 Btu/hr
• Piezo Ignition
• Pressure Regulator Setting: 6" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 10.5" W.C., Minimum - 7" W.C.
• Average Heater Weight: 22 lb (10 kg)
• Average Shipping Weight: 25.5 lb (11.6 kg)
LCR30NT, HDR30NT
• Natural Gas
• 30,000 Btu/hr
• Piezo Ignition
• Pressure Regulator Setting: 6" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 10.5" W.C., Minimum - 7" W.C.
• Average Heater Weight; 29 lb (13.2 kg)
• Average Shipping Weight: 33 lb (15 kg)
LCR16PT, HDR16PT
• Propane/LP Gas
• 16,000 Btu/hr
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
• Average Heater Weight: 22 lb (10 kg)
• Average Shipping Weight: 25.5 lb (11.6 kg)
LCR26PT, HDR26PT
• Propane/LP Gas
• 26,000 Btu/hr
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
• Average Heater Weight: 29 lb (13.2 kg)
• Average Shipping Weight: 33 lb (15 kg)
Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
ACCESSORIES
EQUIPMENT SHUTOFF vALvE
GA5010
For all models.
Equipment shutoff valve with
1/8" NPT tap.
Purchase these heater accessories from your
local dealer. If they can not supply these ac
-
cessories, either contact your nearest Parts
Central (see page 25) or call DESA Heating
Products at 1-866-672-6040 for referral in
-
formation. You can also write to the address
listed on the back page of this manual.
ELECTRONIC IGNITOR KIT - GA435
Not Shown
For all piezo ignitor models.
Provides easier
lighting of the pilot.