PILOT

LO

OFF

HI

 CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

Figure 16 - Pilot

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
above.

2.

Make sure manual shutoff valve is
fully open.

3.

Turn control knob clockwise 

Clockwise

to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Fol-
low “B” in the safety information in
column 1. If you don’t smell gas, go
to the next step.

5.

Turn control knob counterclockwise

C-clockwise

 to the PILOT position.

Press in control knob for five (5) sec-
onds (see Figure 15).

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The pilot can
be seen through the glass panel. If
needed, keep pressing ignitor button
until pilot lights.

Figure 15 - Control Knob In The OFF
Position

Ignitor Button

Control Knob

Note:

 If pilot does not stay lit, refer

to Troubleshooting, pages 15 through
17. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure, 
page 12.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

Note:

 If pilot goes out, repeat steps

3 through 7. Wait one (1) minute be-
fore lighting pilot again.

8.

Turn control knob counterclockwise

C-clockwise

 to desired heating level. The

main burner should light. Set control
knob to any heat level between HI
and LO.

Thermocouple

Ignitor Electrode

Pilot Burner

OPERATING
HEATER

THERMOSTAT MODELS
FAS-20BB AND FAS-30BB

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Summary of Contents for Glo-Warm FA-20BB

Page 1: ...s If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed...

Page 2: ...y system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 6 Keep all air openings in front and bot tom of heater clear and fr...

Page 3: ...ptly inform dealer where you bought heater Figure 1 Vent Free Natural Gas Heater Models FAS 20BB Shown Ignitor Button Control Knob Heater Cabinet Front Panel PRODUCT FEATURES SAFETY DEVICE This heater...

Page 4: ...ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to t...

Page 5: ...include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr use...

Page 6: ...attic will activate the power vent AIR FOR COMBUSTION AND VENTILATION Continued Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 12 12 Ventilation Grills int...

Page 7: ...l sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps et...

Page 8: ...where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall see Fig ure 7 Note Only mark last hole on each end of mounting bracket Insert mounting screws through th...

Page 9: ...clogged heater valves Installsedimenttrapinsupplylineasshown in Figure 12 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap where trapped matter is not likely to freeze...

Page 10: ...aks at once CHECKING GAS CONNECTIONS INSTALLATION Continued TestPressuresEqualToorLessThan 1 2 PSIG 3 5 K Pa 1 Close manual shutoff valve see Fig ure 13 2 Pressurize supply piping system by ei ther us...

Page 11: ...r lighting pilot After 30 seconds release control knob Ifcontrolknobdoesnotpopupwhen released contact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 3 throu...

Page 12: ...er Light ing Instructions page 11 3 With control knob pressed in strike match Hold match to pilot until pi lot lights 4 Keep control knob pressed in for 30 seconds after lighting pilot After 30 second...

Page 13: ...place front panel MANUAL LIGHTING PROCEDURE Figure 17 Control Knob In The OFF Position Figure 18 Pilot 7 Press in control knob and turn back to PILOT IGN This should cause the piezo ignitor to spark a...

Page 14: ...hermostat models or page 13 for non thermostat models seeTroubleshooting pages 15 through 17 CORRECT FLAME PATTERN AT HIGH POSITION 1 2 G Figure 21 Correct Burner Flame Pattern Yellow Tipping 1 2 G IN...

Page 15: ...as pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched b...

Page 16: ...ator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local n...

Page 17: ...ment at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM...

Page 18: ...x D Heater Includes knobs grill 23 x 18 75 x 7 23 x 18 75 x 7 23 x 26 x 7 23 x 26 x 7 23 x 26 x 7 Carton 26 x 21 x 9 26 x 21 x 9 26 x 28 5 x 9 26 x 28 5 x 9 26 x 28 5 x 9 Weight pounds Heater 21 21 5...

Page 19: ...All States 219 462 7441 1 800 362 6951 FBD 1349 Adams Street Bowling Green KY 421033414 502 846 1199 1 800 654 8534 Four Flags Power Products 1115 Stateline Road Niles MI 49120 4728 616 684 2697 1 80...

Page 20: ...ME NATURAL GAS HEATER ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS FAS 20BB FAS 30BB 7 7 28 2 28 27 22 26 23 19 17 24 25 12 26 21 20 18 9 8 18 16 10 16 13 1 14 14 15 7 29 11 3 4 5 7 6 7 7 24 1 24 2 O...

Page 21: ...ssure Regulator 1 14 L98801 01 L98801 01 Washer 2 15 L98806 01 L98806 01 Self Tapping Screw 2 16 L98115 03 L98115 03 Main Inlet Tube Assembly 1 17 L98123 06 L98123 06 ODS Line Assembly 1 18 L98126 01...

Page 22: ...HEATER ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS FA 20BB FA 30BB AND FGH 30NGB 8 8 32 2 32 31 26 30 27 23 17 28 29 10 30 25 24 22 16 13 1 17 22 20 9 16 18 19 14 14 15 8 12 11 33 3 7 4 5 8 6 8...

Page 23: ...Inlet Tube Assembly 1 17 L98123 09 L98123 08 L98123 08 ODS Line 1 18 L98127 01 L98127 01 L98127 01 Lower Gas Outlet Tube Assembly 1 19 L98128 01 L98128 01 L98128 01 Medium Gas Outlet Tube Assembly 1 2...

Page 24: ...he heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original conditio...

Reviews: