background image

www.desatech.com

1

117001-01B

Figure 19 - Pilot

LIGHTING 

INSTRUCTIONS

1.  STOP! Read the safety information, page 12.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Turn off any electric power to the appliance 

if service is to be performed.

4.  Turn control knob clockwise 

 to the 

OFF position.

5.  Wait five minutes to clear out any gas. Then 

smell for gas, including near the floor. If you 

smell gas, STOP! Follow “B” in the safety 

information, page 12. If you don’t smell gas, 

go to the next step.

6. 

Thermostat Models:

 Turn control knob coun

-

terclockwise 

 to the PILOT position. 

Press in control knob for five (5) seconds.

 

Manual  Models:

 Press in and turn control 

knob counterclockwise 

 to the PILOT 

position. Keep control knob pressed in for five 

(5) seconds.

7.  With control knob pressed in, push down and 

release ignitor button. This will light pilot. 

The pilot is attached to the front of burner. 

Note:

 

You may be running this heater for the 

first time after hooking up to gas supply. If so, 

you may need to press in control knob for 30 

seconds or more. This will allow air to bleed 

from the gas system. If needed, keep press

-

ing ignitor button until pilot lights. If ignitor 

does not light pilot, refer to 

Troubleshooting

page 16 or contact a qualified service person 

or gas supplier for repairs. Until repairs are 

made, light pilot with match. To light pilot 

with match, see 

Manual Lighting Procedure

page 14.

8.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob.

• If control knob does not pop up when re

-

leased, contact a qualified service person or 

gas supplier for repairs.

 

Note:

 If pilot goes out, repeat steps 4 thru 7. 

Thermostat models have a safety interlock 

system. Wait one (1) minute before lighting 

pilot again.

9.  Turn control knob counterclockwise 

 to 

desired heating level. The main burner should 

light. Manual control heaters should be used 

in locked positions.

Figure 17 - Control Knob In The OFF 

Position for Manual Control Models

Figure 18 - Control Knob In The OFF 

Position for Thermostat Models

OF

F  

  P

ILO

Control 
Knob

Ignitor 
Button

OPERATING HEATER

Continued

Ignitor Button

Control 
Knob

 WARNING: Always operate 

manual  control  heaters  at  the 

locked  positions.  Operation 

between  these  positions  may 

create a possible health hazard 

if  used  in  a  poorly  ventilated 

room. Read owner’s manual for 

complete instructions.

 CAUTION: Do not try to ad-

just heating levels by using the 

equipment shutoff valve.

Thermocouple

Pilot 
Burner

Ignitor Electrode

TO TURN OFF GAS 

TO APPLIANCE

Shutting Off Heater

1.  Turn control knob clockwise 

 to the 

OFF position.

2.  Turn off all electric power to the appliance if 

service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise 

 to the PILOT 

position.

Summary of Contents for DWN6

Page 1: ...flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in yo...

Page 2: ...cer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble operate or service this heater Improper use of this heater can cause...

Page 3: ...propane LP supply tank s in side any structure Locate propane LP supply tank s outdoors 3 Do not install 10 000 Btu hr units in a bath room 6 000 Btu hr heaters are allowed in a bathroom 4 If you smel...

Page 4: ...upon sale of the unit Vent free gas products are prohibited for bed room and bathroom installation in the Com monwealth of Massachusetts Unpacking 1 Remove heater from carton 2 Remove all protective...

Page 5: ...e air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusual...

Page 6: ...ls or ducts DETERMINING FRESH AIR FLOW FOR Heater LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space Space Incl...

Page 7: ...this heater as your primary heat source WARNING A qualified ser vice person must install heater Follow all local codes CHECK GAS TYPE Use only the correct type of gas natural or pro pane LP If your g...

Page 8: ...currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as but not limited to tobacco smoke...

Page 9: ...thick walls over 1 2 1 3 cm thick or solid walls do not pop open wings 5 Tighten two screws until 1 16 1 6 mm space thickness of penny is between screwheads and wall see Figure 8 Installation Continu...

Page 10: ...codes Use pipe of large enough diameter to allow proper gas volume to heater If pipe is too small undue loss of volume will occur Installation Continued Figure 12 External Regulator With Vent Pointin...

Page 11: ...pliance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where equipme...

Page 12: ...sion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con...

Page 13: ...ntil repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 14 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release...

Page 14: ...Pilot Burner Thermocouple Blue Flame Yellow Flame Figure 20 Correct Pilot Flame Pattern Figure 21 Incorrect Pilot Flame Pattern Note The pilot flame on natural gas units will have a slight curve but f...

Page 15: ...ason Blocked air holes will create soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person We also recommend that y...

Page 16: ...s when in stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Replace pilot assembly 2 Replace pilot assembly 3 Reconnect ignitor cable...

Page 17: ...knob fully 2 After ODS pilot lights keep control knob pressed in 30 seconds 3 Fully open equipment shutoff valve 4 Hand tighten until snug then tighten 1 4 turn more 5 A Contact local natural or propa...

Page 18: ...lace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to lowest position and let warm up for a minute 2 Operate burner until air is removed from line Have gas check...

Page 19: ...ance page 15 1 Locate and correct all leaks see Checking Gas Connec tions page 11 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking...

Page 20: ...www desatech com 117001 01B 20 9 11 10 1 2 3 4 5 6 7 8 10 12 13 14 16 17 20 21 19 23 22 18 24 15 Illustrated Parts Breakdown Models GWP6 GWN6 GWP10 and GWN10 11 1 11 ODS Pilot...

Page 21: ...7 Pilot Tubing 1 14 104259 01 Injector 1 piece 1 104259 02 Injector 1 piece 1 104259 03 Injector 1 piece 1 104259 04 Injector 1 piece 1 15 NJF 8C Hex Nut 1 16 099415 17 Pressure Regulator 1 099415 18...

Page 22: ...www desatech com 117001 01B 22 ILLUSTRATED PARTS BREAKDOWN Models GWP10T and GWN10T 15 1 2 3 5 6 7 8 4 13 9 10 12 13 14 11 17 19 18 9 20 21 16 11 1 11 ODS Pilot...

Page 23: ...ly 1 11 1 110186 01 Thermocouple Kit 1 12 104263 03 Burner 1 13 099387 11 Pilot Tubing 1 14 104259 05 Injector 1 Piece 1 104259 06 Injector 1 Piece 1 15 NJF 8C Hex Nut 1 16 099415 17 Pressure Regulato...

Page 24: ...ensions H x W x D 25 x 16 75 x 7 75 63 5 x 42 5 x 19 7 cm Heater Weight 13 5 6 1 kg Heater Shipping Weight 15 lb 6 8 kg GWP6 4 400 6 000 Btu hr Variable Propane LP Gas Piezo Ignition Pressure Regulato...