background image

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

www.desatech.com

KEEP THIS WARRANTY

WARRANTY INFORMATION

Model

Serial No.

Date Purchased

104463-01
Rev. C
02/00

INTERNATIONAL

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.

NOT A UPC

LIMITED WARRANTY

VENT-FREE PROPANE/LP GAS LOG HEATERS AND EMPIRE STOVE CHASSIS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first
purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this
heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA
International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become
damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic
cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE
PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS
THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA
INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA
INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

104463 01

Summary of Contents for Comfort Glow SL30NT

Page 1: ...and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen fro...

Page 2: ...ing could occur due to log curing and heater burning manufactur ing residues 8 To prevent the creation of soot follow the instructions in Cleaning and Main tenance page 15 9 Before using furniture pol...

Page 3: ...s no heat loss out a vent or up a chimney Heat is generated by realistic dancingyellowflames Thisheater is designed for vent free operation State and local codes in some areas prohibit the use of vent...

Page 4: ...one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such...

Page 5: ...o not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu H...

Page 6: ...from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two...

Page 7: ...If you can pro vide greater clearances from floor ceiling and adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor...

Page 8: ...to leg Thread bolt in tapped holes on stove body see Figure 8 and Figure 9 page 9 Figure 7 Removing Pallet Wood From The Bottom of The Stove Figure 8 Locating Threaded Holes for Stove Bottom Legs and...

Page 9: ...ot holes and into threaded hole in stove body see Fig ure 11 Use an adjustable wrench or a 12mm socket to fasten step bolt Tighten step bolt until snug Make sure door moves freely 11 Install door catc...

Page 10: ...ounting hole and through stove bot tom Connect hex nut to bolt on under side of stove bottom The bolt hex head is for a 5 16 socket and the hex nuts are for a 3 8 socket If sockets are not available u...

Page 11: ...deofthe stove when viewed from the front of the unit The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure 17 Make sure gas log...

Page 12: ...at once 6 Reconnect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig...

Page 13: ...stays lit Turn control knob clockwise to the PILOT position 1 STOP Read the safety information column 1 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF posit...

Page 14: ...lso visit DESA International s technical service web site at www desatech com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater will not prod...

Page 15: ...tube and pilot assembly clean and free of dustanddirt Tocleanthesepartswerecom mend using compressed air no greater than 30 PSI Your local computer store hard ware store or home center may carry com...

Page 16: ...ouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace piezo ignitor 5 R...

Page 17: ...ine Have gas line checked by local natural gas company 3 Observe minimum installation clear ances see page 7 4 Clean burner see Cleaning and Mainte nance page 15 or replace burner orifice 1 Properly l...

Page 18: ...e just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This i...

Page 19: ...Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com Ea...

Page 20: ...20 104463 VENT FREE NATURAL GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN SL30NT 14 16 3 4 15 5 11 6 12 7 10 15 8 9 1 17 2 18 18 18 13...

Page 21: ...5 01 Inlet Tube 1 7 104424 01 Outlet Burner Tube 1 8 099056 26 Burner Orifice Injector 1 9 102843 01 Burner Clip 1 10 102980 01 Burner 1 11 101329 21 Control Valve 1 12 104472 01 Bracket 1 13 099211 0...

Page 22: ...22 104463 VENT FREE NATURAL GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN CISC CISG 7 4 6 4 5 4 5 1 5 2 3 5 3 5 4 2 1R 1C 1L...

Page 23: ...m 1 4 104970 01 One Leg Charcoal 4 Total Per Stove 1 104970 02 One Leg Forest Green 4 Total Per Stove 1 5 104971 01 Hardware Kit 1 5 1 Door Hinge Step Bolt With Shoulder 1 Per Unit 1 5 2 Door Catch Bo...

Page 24: ...ed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear...