When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• natual gas supply may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burners will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.

SERVICE HINTS

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our
customer’s needs by providing original replacement parts and accessories.

Btu (Variable)

20,000/26,000

Type Gas

Natural Only

Ignition

Piezo

Manifold Pressure

3.0" W.C.

Inlet Gas Pressure
  (in. of water) *

Maximum

10.5"

Minimum

5"

Dimensions, Inches (H x W x D)

Stove

24 x 27 

1

/

4

 x 17 

1

/

4

Carton

22 x 31 x 31 

1

/

2

Weight, pounds

Stove

66 lbs.

Shipping

80 lbs.

* For purposes of input adjustment

Baltimore Electric

1348 Dixwell Avenue
Hamden, CT 06514-0322
1-800-397-7553
203-248-7553
Parts Department

Portable Heater Parts

342 N. County Rd. 400 East
Valparaiso, IN 46383-9704
All States
219-462-7441
1-800-362-6951
[email protected]
[email protected]

FBD

1349 Adams Street
Bowling Green, KY 42103-3414
270-846-1199
1-800-654-8534
Fax: 1-800-846-0090
[email protected]

Master Parts Dist.

1251 Mound Ave NW
Grand Rapids, MI 49504-2672
616-791-0505
1-800-446-1446
Fax: 616-791-8270
www.nbmc.com

Washer Equipment Co.

1715 Main Street
Kansas City, MO 64108-2195
KS, MO, AR
816-842-3911
www.washerparts.com

East Coast Energy Products

707 Broadway
W. Long Branch, NJ 07764-1542
732-870-8809
1-800-755-8809
www.njplaza.com/ecep

Dayton Hardware

P.O. Box 275
North Dayton Station
Dayton, OH 45404-0275
All States
937-258-3721
OH 1-800-762-3426

Halco Enterprises

208 Carter Drive, Unit 21
West Chester, PA 19382-4500
610-430-7717
1-800-368-0803
www.halcoenterprises.com

Laporte’s Parts & Service

2444 N. 5th Street
Hartsville, SC 29550-7704
803-332-0191
Parts Department

Cans Unlimited, Inc.

P.O. Box 645
Taylor, SC 29687-0013
All States
803-879-3009
1-800-845-5301
[email protected]

Summary of Contents for Comfort Glow S26NT

Page 1: ...ce must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damage Re fer to...

Page 2: ...tion of soot follow the instructions in Cleaning and Main tenance page 13 8 Before using furniture polish wax car pet cleaners or similar products turn heater off If heated the vapors from these produ...

Page 3: ...1 Remove top inner pack 2 Tilt carton so that stove is upright 3 Remove protective side packaging 4 Slide stove out of carton 5 Remove protective plastic wrap 6 Remove screen by lifting and then pull...

Page 4: ...herearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombusti...

Page 5: ...iances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr ma...

Page 6: ...igure 2 Ventilation Air from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined spac...

Page 7: ...reater clearances from floor ceiling and adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must ma...

Page 8: ...r cleaning Install in piping system betweenfuelsupplyandheater Locatesedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from go...

Page 9: ...connect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 7 2 Pre...

Page 10: ...onnectpowercordwiresfromblower motor if connected see Figure 12 4 Disconnect green ground wire from blower housing if connected by re moving screw holding wire terminal see Figure 12 5 Install one pla...

Page 11: ...igure 16 14 Using two screws provided in blower kit mount blower speed control hous ing to mounting tab in left side of lower control compartment see Figure 16 15 Checktomakesurethatthepowercordis com...

Page 12: ...pat tern Figure 20 shows an incorrect pilot flame pattern Note Appearance of pilot assembly may vary by model The incor rect pilot flame is not touching the thermo couple This will cause the thermoco...

Page 13: ...cleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or home center may carry compressed air in a can You can...

Page 14: ...ged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set...

Page 15: ...ute 2 Operate burner until air is removed from line Have gas line checked by local natu ral gas company 3 Observe minimum installation clearances see pages 7 through 9 4 Clean burner see Cleaning and...

Page 16: ...ater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Burner flame is excessively large and is very near or to...

Page 17: ...4 x 27 1 4 x 17 1 4 Carton 22 x 31 x 31 1 2 Weight pounds Stove 66 lbs Shipping 80 lbs For purposes of input adjustment Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 2...

Page 18: ...18 105683 VENT FREE NATURAL GAS PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S26NT 5 7 6 9 13 4 10 3 2 1 14 15 12 11 10 8...

Page 19: ...t 1 2 14285 01 ODS Pilot NG 1 3 098249 01 ODS Nut 2 4 105973 01 Burner Outlet Tube 1 5 105737 01 Injector Holder 1 6 102843 01 Burner Clip 1 7 099056 27 Burner Orifice Injector 1 8 101329 25 Gas Contr...

Page 20: ...20 105683 VENT FREE NATURAL GAS PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S26NT 1 4 13 3 2 14 7 16 15 11 18 10 5 6 9 8 17 12...

Page 21: ...5661 01 Firebox Top Assembly 1 11 105970 01 Screen Assembly 1 12 101382 01 Valve Bracket 1 13 105672 01 Brass Trim Bottom 1 14 105673 01 Brass Trim Firebox 1 15 106754 01 Knob 1 16 105971 01 Door Hing...

Page 22: ...Parts Central see page 17 If they can t supply original replacement part s call DESA International s Parts Department at 1 800 972 7879 for referral information WhencallingDESAInternational haveready...

Page 23: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Page 24: ...sedbyimproperinstallation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTEN...

Reviews: