background image

NATURAL GAS LOG

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or
loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any
other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed by

a qualified installer, service agency, or the
gas supplier.

WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational
procedures. For assistance or
additional information consult
a qualified installer, service
agency, or the gas supplier.

WARNING: This appliance is
for installation only in a solid-
fuel burning masonry or UL127
factory-built fireplace, con-
structed of noncombustible
material, and connected to a
working flue. (See page 4 for
minimum flue opening.)

WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to 

Air for Combustion and Ventilation section on page 4 of this manual.

VENTED DECORATIVE APPLIANCES

OWNER’S OPERATION AND INSTALLATION MANUAL

Save this manual for future reference.

Burner Models
HFVMR18 and
HFVMR24

RGA 2-72

APPROVED

TESTED AND

LISTED BY

This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.

*

 Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Summary of Contents for Comfort Glow RGA 2-72

Page 1: ...l for correct installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installati...

Page 2: ...ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set with a fire placescreeninplace Makesurefirepl...

Page 3: ...appliance See Acces sories page 13 A wall switch is also available for this appliance Youmustusethemillivoltvalve safety pilot kit to use the wall switch with this appliance See Accessories page 13 U...

Page 4: ...Side 65 000 55 000 8 dia Btu Input Natural Gas Btu Input Propane Gas Minimum Vent Opening MINIMUM FIREBOX SIZES LOG FRONT BACK SIZE WIDTH WIDTH DEPTH HEIGHT 18 28 28 16 18 24 29 3 4 29 3 4 16 18 Add 6...

Page 5: ...below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection adjustable crescent wrench or pliers sediment trap tee joint pipe wrench CAUTION Use on...

Page 6: ...6 Make sure the burner ports face downward 3 Using thread sealant resistant to the ac tion of propane LP gas on larger end of fitting screw the burner inlet fitting through hole and into burner manifo...

Page 7: ...Flame Adjustment Adjust the flame ON OFF by turning the gas shutoff valve counterclockwise to open or clockwise to close as necessary Shutting Off Appliance Turn gas shutoff valve clockwise to the OF...

Page 8: ...Log set is smoking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with p...

Page 9: ...ED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion...

Page 10: ...10 901915 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN HFVMR18 HFVMR24 3 6 12 10 11 10 4 7 9 5 1 8 2...

Page 11: ...atural Gas 1 4 901064 10 901064 03 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assembly 1 8 901232 01 90123...

Page 12: ...eplacement Parts on page 13 of this manual KEY PART NUMBER FOR NO 18 24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619 01 901619 01 FS 12Y Top L...

Page 13: ...n For all models Use for firebox decoration nly SILICA SAND GA9850 Not Shown For all models Use for firebox decoration only Carton of 6 LAVA ROCK GA6067 Not Shown For all models Use for firebox decora...

Page 14: ...aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO A...

Page 15: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 16: ...related to repairing a defective log set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND A...

Reviews: