background image

7

104887

OWNER’S MANUAL

INSTALLATION

 CAUTION: This fireplace cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

Note:

 Your Comfort Glow fireplace is de-

signed to be used in zero clearance installa-
tions. Wall or framing material can be placed
directly against any exterior surface on the
rear, sides, or top of your  fireplace, except
where standoff spacers are integrally at-
tached. If standoff spacers are attached to
your fireplace, these spacers can be placed
directly against wall or framing materials.

 WARNING: A qualified ser-

vice person must install fireplace.
Follow all local codes.

 WARNING: Never install the

fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the fireplace

• in high traffic areas
• in windy or drafty areas

ASSEMBLING AND
ATTACHING OPTIONAL
BRASS TRIM
(Included with Mantel
Accessory)

IMPORTANT:

 If you are recessing the fire-

box in a wall, do not attach brass trim at this
time. See page 9.

Note:

 The instructions below show assem-

bling and attaching brass trim to fireplace.
1.

Remove packaging from three pieces
of brass trim.

2.

Locate four brass screws, two adjust-
ing plates with set screws, and two
shims in the hardware packet.

3.

Align shim under adjusting plate as
shown in Figure 5.

4.

Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 5).

5.

Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 5).

6.

While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.

7.

Repeat steps 1 through 6 for other side.

8.

Tighten trim hanging screws (#10 x
6.25 shoulder) into holes in cabinets.
Place the assembled trim onto fireplace
cabinet. Align hanging notches on trim
with hanging screws on side of fire-
place (see Figure 6). Push trim firmly
into place, sliding hanging notches over
hanging screws.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 9).

IMPORTANT:

 Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, 
pages 4 through 6.

IMPORTANT:

 Make sure the fireplace is

level. If fireplace is not level, log set will not
work properly.

CHECK GAS TYPE

Use only natural gas. If your gas supply is
not natural gas, do not install fireplace. Call
dealer where you bought fireplace for proper
type fireplace.

ELECTRICAL HOOKUP

(Optional Blower Accessory)

This fireplace accepts a blower assembly
with an electrical cord. The electrical cord is
five feet in length. You must locate fireplace
within reach of a 120 volt grounded electri-
cal outlet. If not, you must install an electri-
cal outlet within reach of fireplace power
cord.

Continued

Figure 5 - Assembling Brass Trim

Side Brass
Trim

Top
Brass
Trim

Slot

Mitered Edge

Slot

Shim

Set Screws

Adjusting
Plate

Figure 6 - Attaching Brass Trim to
Fireplace

Trim
Hanging
Screws

Assembled
Brass Trim

Hanging
Notches
on Trim

Summary of Contents for Comfort Glow LFP33NR

Page 1: ...lation adjustment alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation c...

Page 2: ...eplace 7 You must operate this fireplace with the fireplace screen and hood in place Make sure fireplace screen and hood are in place before running fireplace 8 This fireplace is designed to be smoke...

Page 3: ...e heater front Lift the heater off the bottom tray 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remov...

Page 4: ...uate combustion and ventilation air Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION This vent free fireplace is clean...

Page 5: ...tu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount o...

Page 6: ...s Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoo...

Page 7: ...es of brass trim together tighten both set screws on the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes...

Page 8: ...1 Assemble cabinet mantel hearth base and trim accessories Assembly instruc tions are included with each accessory 2 When installing blower install a prop erly grounded 120 volt three prong electrical...

Page 9: ...er use dimen sions shown in Figure 13 for the rough opening The height is 33 which is the same as the wall opening above 2 If using blower install and properly ground GA3555 three prong 120 volt elect...

Page 10: ...certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of pressure will occur Mantel Clearances for Built In...

Page 11: ...for shipping These screws are located near top of screen Discard screws Lift fireplace screen up and pull out to remove 2 Remove screws that attach log base assembly to fireplace see Figure 17 Carefu...

Page 12: ...or opening main gas valve located on or near gas meter 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all l...

Page 13: ...cutout on the right of the middle log should fit over the burner see Fig ure 21 Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen tered over the...

Page 14: ...re mote control unit following direction of arrow 2 Insert twoAAAbatteries following dia gram in battery housing area 3 Replace battery cover onto remote con trol unit Figure 30 Installing Battery in...

Page 15: ...he battery Place battery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 35 Installing Battery in Hand Held Remote Control Unit Battery Cover 9 Volt Battery Terminal...

Page 16: ...switch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Fol...

Page 17: ...HIandLO Slide thee selector switch to the REMOTE po sition Note The burners may light if hand heldremoteONbuttonwasonwhen selector switch was last turned off You can now turn the burners on and off wi...

Page 18: ...eater and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the p...

Page 19: ...connect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Repl...

Page 20: ...requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum...

Page 21: ...ntilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local...

Page 22: ...ntat1 800 DESALOG 1 800 337 2564 You can also visit DESA International s Technical Service web site at www desatech com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will...

Page 23: ...sories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 4...

Page 24: ...6F Series Walnut Finished Birch Veneer GMC37U Series Unfinished Birch Veneer Ready to Stain or Paint Space saving corner mantels feature mold ings fluting and medallion Dimensions H xW xD 48 3 4 x 60...

Page 25: ...LD REMOTE CONTROL RM4 For remote control operation Installation and limited operation instructions included in this manual Extended operation instruc tions included with remote Hand held re mote contr...

Page 26: ...UNVENTED NATURAL GAS FIREPLACE LFP33NR ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL LFP33NR 20 30 7 O F F P I L O T O N H I L O 11 15 29 10 9 7 6 5 8 12 31 17 16 28 18 19 24 14 13 22 23 22 26 27 25...

Page 27: ...e Injector 1 11 102772 01 Burner 2 12 M11084 38 Screw 8 x 38 2 13 104236 01CK Painted Base Assy 1 14 M12461 26 Screw 10 x 32 6 15 104238 01CK Firebox Bottom 1 16 103284 03 Wiring Harness 1 17 098265 0...

Page 28: ...28 104887 UNVENTED NATURAL GAS FIREPLACE LFP33NR ILLUSTRATED PARTS BREAKDOWN FIREPLACE LFP33NR 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13...

Page 29: ...Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CK Firebox Wrapper 1 9 103412 01CK Louver Door 1 10 101727 02 Screen Assembly 1 11 101348 01 Firebox Support 2 12 103208 01...

Page 30: ...ated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OT...

Reviews: