Actual 

Framing

Height 

32 

3

/

16

33"

Front Width  

34 

5

/

16

35 

1

/

2

"

Depth 

16 

11

/

16

17 

3

/

4

"

Figure 15 - Location of Nailing Flanges 

Nailing 
Flanges 

Figure 16 - Inserting Firebox Into Cabinet 

Mantel

INSTALLATION

Continued 

BUILT-IN FIREBOX INSTALLATION

Built-in installation of this firebox involves in-

stalling firebox into a framed-in enclosure. This 

makes the front of firebox flush with wall. Optional 

perimeter trim is available (see 

Accessories

, page 

12) This perimeter trim will extend past sides of 

firebox approximately 1/2 inch. This will cover 

rough edges of the wall opening. If installing a 

mantel above the firebox, you must follow the 

clearances  shown  in  Figure  7,  page  8.  Follow 

the  instructions  below  to  install  the  firebox  in 

this manner.
1.  Frame in rough opening. Use dimensions shown 

in Figure 17 for the rough opening. If installing 

in a corner, use dimensions shown in Figure 18 

for the rough opening. The height is 33", which 

is the same as the wall opening in Figure 17. 

2.  Install gas piping to firebox location. This instal-

lation includes an approved flexible gas line (if al-

lowed by local codes) after the equipment shutoff 

valve. The flexible gas line must be the last item 

installed on the gas piping. See 

Connecting to 

Gas Supply

 in log set ownerʼs manual. 

Figure 17 - Rough 

Opening for 

Installing in Wall 

39 

3

/

8

"

27 

7

/

8

"

55 

5

/

8

"  

34 

3

/

4

"

Figure 18 - Rough 

Opening for Installing 

in Corner 

34 

3

/

4

"

17 

3

/

4

"

33" (CGFB32C)
34 

1

/

4

" (CGFB32NC)

3.  Carefully set firebox in front of rough open-

ing with back of firebox inside wall opening.  

IMPORTANT:

 If installing perimeter trim, 

see  instructions  included  with  perimeter 

trim  accessory.  You  must  install  shoulder 

screws now.

4.  If using GA3750A blower accessory, see

 Built-

In Installation of Blower Accessory

, page 8. 

5.  Attach flexible gas line to log set. See 

Connect-

ing to Gas Supply

 in log set ownerʼs manual. 

6.  Carefully insert firebox into rough opening.
7.  Attach firebox to wall studs using nails or 

wood screws through holes in nailing flange 

(see Figure 19).

8.  Check all gas connections for leaks. See 

Checking 

Gas Connections

 in log set ownerʼs manual. 

9.  If using optional perimeter trim, install the 

trim after final finishing and/or painting of 

wall. See instructions included with perimeter 

trim accessory for attaching perimeter trim.

Figure 19 - Attaching Firebox to Wall Studs 

Nailing 
Flanges

Nails or 
Wood 
Screws 

Summary of Contents for Comfort Glow CGFB32CA

Page 1: ...I Z21 91 for use with any ANSI Z21 11 2 ap proved gas logs This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This appl...

Page 2: ...ol before touching SAFETY INFORMATION TABLE OF CONTENTS Safety Information 2 Local Codes 3 Unpacking 3 Product Features 3 Product Speci cations 4 Locating Firebox 4 Air For Combustion and Ventilation...

Page 3: ...ETY INFORMATION Continued 10 Do not use the rebox if it has been under water due to the shock hazard that could result with the blower accessary if installed in place 11 Provide adequate clearances ar...

Page 4: ...cient than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out an...

Page 5: ...h doors are considered a part of the uncon ned space Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them AIR FOR COMBUSTION AND VENTILATION Cont...

Page 6: ...adjoining un con ned space When ventilating to an adjoining uncon ned space you must provide two perma nent openings one within 12 of the ceiling and one within 12 of the oor on the wall connecting th...

Page 7: ...youmay run system s circulating blower whileusingheater Thiswillhelp circulatetheheatthroughoutthe house In the event of a power outage you can use this heater as your primary heat source WARNING A q...

Page 8: ...in installation see Built In Installation of Blower Accessory To install blower accessory see in struction sheet included with the kit Side Opening Support Bracket Opening Blower Power Cord Figure 8...

Page 9: ...you desire Note Periodically check the louvers of the rebox and remove any dust dirt or other obstructions INSTALLING LOG HEATER IN FIREBOX CAUTION Donotpickuplog base assembly by burners This could...

Page 10: ...g electri cal outlet at rebox location if an outlet is not there If possible locate outlet so cabinet mantel will cover it when installed see Figure 14 3 Install gas piping to rebox location This inst...

Page 11: ...exiblegasline ifal lowedbylocalcodes aftertheequipmentshutoff valve The exible gas line must be the last item installed on the gas piping See Connecting to Gas Supply in log set owner s manual Figure...

Page 12: ...oducts have ready model number of your replace the replacement part number ACCESSORIES NOTICE Allaccessoriesmaynotbe available for all replace models Purchase these replace accessories from your local...

Page 13: ...er Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 219 462 7441 1 888 619 7060 www portableheaterparts com sales portableheaterparts com techservice portableheaterparts com FBD 1349 Adams Stre...

Page 14: ...www desatech com 107331 01H 14 5 15 15 14 15 16 6 1 15 7 15 13 18 9 8 19 12 17 20 10 4 2 3 2 15 11 17 17 ILLUSTRATED PARTS BREAKDOWN MODEL CGFB32CA...

Page 15: ...4 101932 04 Side Firebrick 2 5 103207 01 Outer Casing 1 6 103208 01 Outer Shell Base 1 7 Firebox Wrapper 1 8 103297 01 Assembly Screen 2 9 M12461 2 Screw Outlet Mounting 1 10 103773 05CK Front Assembl...

Page 16: ...me damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to...

Reviews: