background image

Summary of Contents for Comfort Glow CGCF26TN

Page 1: ...aller service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For as sistance or additional informa tion consult a qualified installer service agency or the gas sup lier WARNING This is an unvented gas fired heater It uses air oxy gen fr...

Page 2: ...ctrical shock and carbon monoxide poisoning I DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble theflu with headaches dizziness ornausea Ifyou have these signs the f u eplacemay not be working properly Get fresh air at once Have fireplace serviced Some people are more affected bycarbonmonoxide than others These include pr...

Page 3: ...sidues 9 Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting 10 This fireplace needs fresh air ventilation to run properly This fireplace has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the fireplace if not eno...

Page 4: ...ireplace if there is not enough fresh air Piezo Ignition System This fireplace has a piezo ignitor This system requires no matches batteries or other sources to light fireplace Thermostatic Heat Control This fireplace has a thermostat sensing bulb and a control valve The thermostat will automatically modulate the heat output to maintain a consistent room tempera ture This results in greater firepl...

Page 5: ...y placing notches in screen frame over shoulder screws and pushing down __ Shipping Screw Screw Sack Log 12j _ Figure 2 Assembling Fireplace WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal Injury Assembling Hood 1 Lift screen off heater 2 Remove two 1 3 4 screws ...

Page 6: ... leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction rou must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the outside atmosphere have a continu ous water vapor retarder with a rating of one perm 10_ per pa m or less with openings...

Page 7: ...as heater Btu Hr Gas fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Example Gas water heater 30 000 Btu Hr Vent free fireplace 26 000 Btu Hr Total 56 000 Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu I Ir maximu...

Page 8: ...ngs one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 4 You can also remove door into adjoining room see option 3 Figure 4 Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rework worksheet adding the space of the adj...

Page 9: ...t these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Inlet Air Ventilated Crawl Space Outlet Air Inlet Air To Attic To Crawl Space Figure 5 Ventilation Air from O...

Page 10: ...reater clearances from floor ceiling and joining wall You can recess firebox into the wall You can also position fireplace in the optional cabinet or corner mantels IMPORTANT Only use optional cabinet or corner mantels specified in this manual Purchase the optional mantel from your dealer see Accessories page 29 WARNING Never install the fireplace in a bedroom or a bathroom in a recreational vehic...

Page 11: ...tion inspection and service in coldest part of room An optional blower kit is available from your dealer See Accessories page 29 If planning to use blower locate fireplace near an electrical outlet CEILING 36 Minimum Right Side FLOOR Figure 6 Mounting Clearances As Viewed From Front of Fireplace Shown Built In The Wall CEILING Top Of MantelCan With Wall 36 Minimum Side Right Side Figure 7 Mounting...

Page 12: ...he rough opening The height is 26 _ 8 which is the same as the wall opening above 7 8 Figure 9 Rough Opening for Installing in Comer 2 An optional blower accessory is available see Accessories page 29 There are two options for connecting blower to electrical source Option one Have a licensed electrician install a properly grounded three prong 120 volt electrical outlet at fireplace location Locate...

Page 13: ...igure 10 Attaching Fireplace to Wall Studs 10 Check all gas connections for leaks See Checking Gas Connections page 18 11 If using optional brass trim kit install the trim after final finishing and or painting of wall See instructions included with brass trim accessory for attach ing brass trim Mantel Clearances for Built In Installation If placing mantel above built in fireplace you must meet min...

Page 14: ...l wood screw for attaching fireplace to wooden base Figure 12 Attaching Braee Trim to Fireplace 8 Remove brass trim kit and mantel Be careful not to damage wall or mantel 9 Place wood base next to wall at installation location 10 Attach wood base to floor with two 1 314 black screwsprovided see Figure 13 If the floor is concrete use anchor method seeAttaching WoodBase to Solid Floor page 15 Screw ...

Page 15: ...ewdriver 7 Repeat steps 1 through 6 for other comer 8 Set Brass Assembly aside for later installation Set Screws Slot_ Adjusting Plate Mitered Edge p Brass Trim Side Brass Trim Figure 14 Assembling Brass Trim Attaching Wood Base to Solid Floor For attaching base to solid floors concrete or masonry Note Floor anchorsand mounting screws are in hardware package The hardware package is provided with f...

Page 16: ...each for test gauge hook up NPT tap must be upstream from fireplace see Figure 16 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves CAUTION Use pipe joint sealant that is resistant to liquid petroleum LP gas Install sediment trap in supply line as shown in Figure 16 Locate sediment ...

Page 17: ...in outer casing NOTICE Most building codes do not permit concealed gas connections A flexible gas line is provided to allow accessibility from the fireplace The flexible gas supply line connection to the manual shutoff valve should be accessible 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line see Figure 18 Connect flexible gas line to flexible gas ...

Page 18: ...Equal To or Less Than 1 2 PSIG 1 Close manual shutoff valve see Figure 19 2 Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter 3 Check all joints from gas meter to manual shutoff valve see Figure 20 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks at once PRESSURE TESTING FIREPLAC...

Page 19: ... use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Page 20: ...nitor button This will light pilot The pilot is attached to the front of burner If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 24 through 27 Also contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 21 7 Keep ...

Page 21: ...urner flame height At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any heat level between HI and LO Note The thermostat sensing bulb measures the temperature of air near the fireplace cabinet This may not always agree with room temperature depend ing on...

Page 22: ...t flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the fireplace will shut down Pilot Burner Figure 23 Correct Pilot Flame Pattern Thermocou Pilot Burner Figure 24 Incorrect Pilot Flame Pattern If pilot flame pattern is incorrect as shown in Figure 24 turn fireplace off see To Turn OffGas to Appliance page 21 see Troubleshooting pages 24 t...

Page 23: ... increased levels of carbon monoxide if burner flame pattern shows yellow tipping follow instructions at bottom of this page NOTICE Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the fireplace and burn causing brief patches of orange flame I Top of Flame About One Inch Above Logs CORRECT FLAME PA FFERN AT HIGH POSITION Figure 25 Correct Burner Flame Pattern i t...

Page 24: ...o clean Exterior Use a soft cloth dampened with a mild soap and water mixture Wipe the cabinet to remove dust WARNING Turn off and unplug fireplace and let cool before servicing Only a qualified service person should service and repair fireplace CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit OBSERVED POSSIBLE PROBLEM CAUSE REMEDY When ignitor bu...

Page 25: ...when control knob is released 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Safety interlock system has been triggered 4 Manual shutoff valve not fully open 5 Thermocouple connec tion loose at control valve 6 Pilot flame not touch ing thermoconple which allows thermo couple to cool causing pilot flame to go out This problem could be caused by one or both of the fo...

Page 26: ...ace burner orifice Replace burner pressure Contact local natural gas company Replace gas regulator Yellow flame during burner combustion 1 Not enough air 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance page 24 2 Gas regulator defective 2 Replace gas regulator Slight smoke or odor 1 Residues from manu 1 Problem will stop after a during initial operation factur...

Page 27: ...aint hair spray glues etc See IMPOR TANTstatement above 2 Gas leak See Warn ing statement at top of page 1 Ventilate room Stop using odor causing products while fire place is running 2 Locate and correct al leaks see Checking Gas Connections page 18 Fireplace shuts off in use ODS operates 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or ...

Page 28: ...u may feel your gas pressure is too low or gas quality is bad If so contact your local natural gas supplier Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DES A International s Technical Service Department at 1 80...

Page 29: ...finished appearance covering rough edges of wall opening CABINET MANTEL WITH BUILT IN HEARTH BASE Unfinished Hardwood Veneer GMC16U Walnut Finished Hardwood Veneer GMC15F Medium Stained Oak Veneer GMC17F For use with fireplace A hardwood mantel and hearth base offers compact styling and com pletes the fireplace look Available in a walnut stain medium oak stain or an unfinished hardwood ready to st...

Page 30: ...3O 36 16 CGCF26TN 1O3688 ...

Page 31: ...77 01 102032 02 102807 02 102645 02 102645 01 097809 03 104058 01 Outer Casing Top 1 Outer Casing 1 Shoulder Screw 4 Screw 10 x 3 8 40 Burner 1 Louvered Door 1 Left and Right Side Front 2 Top and Middle Front 2 Top Louver 1 Firebox Hood 1 Firebox Top 1 ODS Pilot Assembly 1 Thermooouple 1 Ignitor Electrode 1 Firebox Wrapper 1 Control Bracket Screw 2 Inlet Tube 1 Outlet Tube 1 Screw Panhead 10 x 1 3...

Page 32: ...son Ave NW Grand Rapids M149504 3458 616 791 0505 Fax 1 616 791 8270 Parts Department Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 Parts Department East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542 908 870 8809 1 800 755 8809 Parts Department Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1 800 922 0724 Parts Department D...

Page 33: ...NOTES 103668 ...

Page 34: ...NOTES m I03668 ...

Page 35: ...NOTES I 10_ ...

Page 36: ...instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace...

Reviews: