18
100098
Pilot
GRH/OV 007G
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow “B” in the safety information
at the top of page 17. If you don’t smell gas, go to the next step.
5. Press in control knob and turn counterclockwise
C-clockwise
to the PILOT
position. Keep control knob pressed in for five (5) seconds (see Figure 16,
page 17).
Note:
You may be running this heater for the first time after hooking up
to gas supply. If so, the control knob may need to be pressed in for 30
seconds. This will allow air to bleed from the gas system.
• If control knob does not pop up when released, contact a qualified
service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This
will light pilot. The pilot is attached to the front of burner. The burner and
pilot are located behind the heat shield. If needed, keep pressing ignitor
button until pilot lights.
Note:
If pilot does not stay lit, refer to Troubleshooting, pages 21 through
24. Also contact a qualified service person or gas supplier for repairs.
Until repairs are made, light pilot with match. To light pilot with match,
see Manual Lighting Procedure, page 19.
Thermocouple
Pilot Burner
Ignitor Electrode
OPERATING
HEATER
Continued
Figure 17 - Pilot
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
8. Turn control knob counterclockwise
C-clockwise
to the LOW position. The
main burner should light. Set control knob to any heat level between HIGH
and LOW. To turn control knob from LOW to a higher setting, press in the
control knob and turn counterclockwise
C-clockwise
.
Note:
Both HIGH and LOW are locked positions. You must press in control
knob before turning it from these positions.
WARNING ICON
G 001
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.