background image

7

103568

OWNER’S MANUAL

Continued

INSTALLING TO
WALL

Continued

INSTALLING HEATER TO
WALL

Mounting Bracket

The mounting bracket is located on back
panel of heater. It has been taped there for
shipping. Remove mounting bracket from
back panel.

Mounting
Bracket

Figure 5 - Mounting Bracket Location

Figure 6 - Removing Front Panel Of Heater

Removing Front Panel Of Heater

1.

Remove two screws near bottom cor-
ners of front panel.

2.

Lift straight up on grill guard until it
stops. Grill guard will slide up about
1/4".

3.

Pull bottom of front panel forward, then
down.

4.

Remove cardboard packing from grill
and glass (CGN20[L]) or heat shield
(RN30D).

Methods For Attaching
Mounting Bracket To Wall

Only use last hole on each end of mounting
bracket to attach bracket to wall. These two
holes are 16 inches apart from their centers.
Attach mounting bracket to wall in one of
two ways.

1.

Attaching to wall stud

2.

Attaching to wall anchor

Marking Screw Locations

1. Tape mounting bracket to wall

where heater will be located. Make
sure mounting bracket is level.

2. Mark screw locations on wall (see

Figure 7).

Note:

 Only mark last hole on each end of

mounting bracket. Insert mounting screws
through these holes only.

3.

Remove tape and mounting bracket
from wall.

16"

18 3/4"

Min.

7 1/4"

Min.

Adjoining Wall

Only Insert Mounting 

Screws Through Last 

Hole On Each End

Floor

RN30D

CGN20(L)

Figure 7 - Mounting Bracket Clearances

 WARNING: Maintain minimum

clearances shown in Figure 7. If
you can, provide greater clear-
ances from floor and joining wall.

32 1/2"

Min.

11"

Min.

16"

Adjoining Wall

Only Insert Mounting 

Screws Through Last 

Hole On Each End

Floor

Attaching to wall stud: 

  This method

provides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.

Attaching to wall anchor

 :  This method

allows you to attach mounting bracket to
hollow walls (wall areas between studs) or
to solid walls (concrete or masonry).

Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.

Figure 9 - Popping Open Anchor Wings
For Thin Walls

Figure 8 - Folding Anchor

Attaching Mounting Bracket To
Wall

Note: 

Wall anchors, mounting screws, and

spacers are in hardware package. The hard-
ware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1.

Drill holes at marked locations using
9/64" drill bit.

2.

Place mounting bracket onto wall. Line
up last hole on each end of bracket with
holes drilled in wall.

3.

Insert mounting screws through bracket
and into wall studs.

4.

Tighten screws until mounting bracket
is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow
walls (wall areas between studs) or solid
walls (concrete or masonry)

1.

Drill holes at marked locations using
5/16" drill bit. For solid walls (concrete
or masonry), drill at least 1" deep.

2.

Fold wall anchor as shown in Figure 8.

3.

Insert wall anchor (wings first) into hole.
Tap anchor flush to wall.

4.

For thin walls (1/2" or less), insert red
key into wall anchor. Push red key to
“pop” open anchor wings.

IMPORTANT: 

Do not hammer key!

For thick walls (over 1/2" thick) or solid
walls, do not pop open wings.

5.

Place mounting bracket onto wall. Line
up last hole on each end of bracket with
wall anchors.

6.

Insert mounting screws through bracket
and into wall anchors.

7.

Tighten screws until mounting bracket
is firmly fastened to wall.

Summary of Contents for CGN20

Page 1: ...appliance may be installed in an aftermarket manufactured mobile home where not prohibited by state or local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer I E In...

Page 2: ...his heater can causeseriousinjuryordeathfrom burns fire explosion electrical shock and carbon monoxide poisoning DANGER Carbon monoxide poisoning may lead to death WARNING Any change to this heater or...

Page 3: ...t space Rooms communicating directly with the space in which the appliances are in stalled through openings not furnished with doors are considered a part of the unconfined space Adjoining rooms are c...

Page 4: ...ining room is supplied with grills or open ings add the volume of these rooms to the total volume of the space 2 Divide the space volume by 50 cubic feet to determine the maximum Btu Hr the space can...

Page 5: ...Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items...

Page 6: ...nts These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air such as tobacco smoke exist may di...

Page 7: ...Hole On Each End Floor Attaching to wall stud This method providesthestrongesthold Insertmounting screws through mounting bracket and into wall studs Attaching to wall anchor This method allows you to...

Page 8: ...optional A G A design certified manual shutoff valve from your dealer See Accessories page 15 Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Pressure Regulator Test Gauge Connection Sediment Tr...

Page 9: ...4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all leaks at once Test Pressures Equal To or Less Than 1 2 P...

Page 10: ...ou may be running this heater for the first time after hook ing up to gas supply If so the con trol knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If co...

Page 11: ...tern shows yellow tipping follow instructions at bottom of this page CORRECT FLAME PATTERN AT HIGH POSITION 1 2 HEAT SHIELD OR GLASS HEIGHT Figure 18 Incorrect Pilot Flame Pattern INSPECTING BURNER Ch...

Page 12: ...ermocoupletocool caus ing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control...

Page 13: ...s line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice REMEDY 1 Clean burner see Cleaning and Mainte nance page 11 or replace burner orifice 2 Contact local natural gas...

Page 14: ...See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ventilation air OBSERVED PROBLEM...

Page 15: ...s H x W x D Heater 23 5 x 25 9 x 8 0 23 5 x 18 5 x 8 0 Carton 26 x 27 75 x 9 63 26 x 20 5 x 9 63 Weight pounds Heater 30 22 Shipping 35 27 ACCESSORIES MANUAL SHUTOFF VALVE GA5010 Forallmodels Manualsh...

Page 16: ...6 103568 VENT FREE NATURAL GAS HEATERS BLUE FLAME CGN20 CGN20L AND RN30D 1 2 4 5 6 7 8 8 9 10 11 12 15 17 19 21 22 23 24 20 27 26 18 14 16 25 3 13 10 1 10 2 ODS Pilot RN30D ILLUSTRATED PARTS BREAKDOWN...

Page 17: ...G 1 10 1 098514 01 Thermocouple 1 10 2 098594 01 Ignitor Electrode 1 11 103447 01 Burner 1 12 099387 05 3 16 Pilot Tubing 1 13 103845 04 Injector 1 14 099066 01 Mounting Bracket 1 15 099415 07 Pressur...

Page 18: ...8 VENT FREE NATURAL GAS HEATERS BLUE FLAME CGN20 CGN20L AND RN30D 12 1 12 2 ODS Pilot 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 17 19 27 21 23 24 25 26 22 29 28 20 16 18 15 CGN20 CGN20L ILLUSTRATED PARTS BR...

Page 19: ...Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 103446 01 Burner 1 14 099387 05 3 16 Pilot Tubing 1 15 103845 02 Injector 1 16 099066 01 Mounting Bracket 1 17 099...

Page 20: ...s When calling a Parts Central ask for the Parts Department REPLACEMENT PARTS Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts...

Page 21: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 22: ...___________________________________________ _______________________________________________________________________________________________ ____________________________________________________________...

Page 23: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 24: ...installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts...

Reviews: