background image

www.desatech.com

117190-01B

6

CLEANING AND 

MAINTENANCE

  WARNING: Always  discon-

nect power and allow the heater 

to  cool  before  performing  any 

cleaning, maintenance or reloca-

tion of this heater. Turn controls 

to  OFF  and  remove  plug  from 

outlet or turn off circuit breaker 

to heater.

Turn off heater and circuit breaker to heater before 

performing any cleaning and/or maintenance. Al-

low heater to cool completely.

BULB REPLACEMENT

 WARNING: The halogen light 

bulbs  in  your  unit  can  become 

extremely hot. Allow at least 10 

minutes between turning off the 

heater  and  removing  the  light 

bulbs to avoid accidental burns.

There are a total of 7 ( halogen light bulbs (type 

GX6.35 rated 120 volts, 35 watts) in your unit.
•  2 bulbs provide illumination for the ember bed 

beneath the log set 

•  2  bulbs  provide  illumination  for  the  flame 

generation assembly

•  1 bulb provides illumination for the top con-

trasting light

•  2 bulbs for replacement
Most halogen light bulbs are rated to last approxi-

mately 1800 hours. Like all light bulbs, halogen 

bulbs  require  periodic  replacement. When  the 

bulbs in your unit have burned out you will notice 

or more of the following:
•  Contrasting light is dark
•  Flame is dim or dark in certain areas
•  Log  set  ember  bed  appears  dim  or  dark  in 

certain areas

  WARNING:  Do  not  install 

replacement bulbs that exceed 

specified maximum watts.

Your unit must be opened in order to replace the 

light bulbs. To reduce the number of times you 

need  to  open  the  unit,  replace  all  bulbs  at  the 

same time. 

Removing Top of Unit

1.  Unplug unit from the power supply.
2.  Remove the two screws at the rear of the unit 

which secure the top to the back frame. 

3.  Two clips hold the top to the sides. Push the 

top of the unit toward the back until the clips 

disconnect. Remove top of the unit and place 

face up on the floor.

4.  Unscrew the 4 screws from the metal plate 

and set plate aside.

Figure 5 - Stove Top Removal

Replacing Top Contrasting Bulb

1.  The housing for the top contrasting light is 

connected to the top of the mirror. Remove 

housing from mirror by gently lifting up.

 CAUTION: Do not force the 

light housing off the mirror. This 

may  damage  the  mirror  (e.g. 

chipping, cracking, etc.)

2.  Remove screws from each side of housing.
3.  Carefully reach into the housing and remove 

spring clip. Hold socket and pull out the old 

bulb.

3.  Hold socket and push in new bulb (DO NOT 

exceed wattage). Replace spring clip.

4.   Set aside until all bulbs have been changed.

Figure 6 - Removing Housing and Top 

Contrasting Bulb

Screw

Housing

Mirror

Front of Stove

Summary of Contents for CGESBL

Page 1: ...ld cause a heater malfunction resulting in serious injury and or property damage Save this manual for future reference For more information visit www desatech com 27 MODELS CGESBL AND VESBL 18 MODELS...

Page 2: ...not use this unit for drying wet clothes 5 Do not operate unit if it is damaged or has mal functioned If you suspect the unit is damaged return it to an authorized service facility for examination el...

Page 3: ...to a properly grounded and pro tected 120 volt outlet Always use ground fault protection where required by the electri cal code WARNING Do not operate the unit if it is damaged or has malfunctioned If...

Page 4: ...nd Control Dial The heater switch has a sun directly below it To turn the heateron iptheHeaterSwitchtoONposition the indicatesONand O indicatesOFF The Control Knob has a thermometer below it Turn the...

Page 5: ...F button once When you hear the beep the replace will be completely off and the ame will disappear When you restart the replace with the remote control all of the features you had set will remain in e...

Page 6: ...ght is dark Flame is dim or dark in certain areas Log set ember bed appears dim or dark in certain areas WARNING Do not install replacement bulbs that exceed speci ed maximum watts Your unit must be o...

Page 7: ...ucted of two removable halves ei ther of which can be removed from the unit 2 Squeeze half of drum cylinder until it s top edge clears the top drum track Remove bot tom edge of cylinder drum from bott...

Page 8: ...t your elec tric stove If so contact DESA Heating Products Technical Service Department at 1 866 672 6040 When calling please have your model and serial numbers of your heater ready You can also visit...

Page 9: ...wall switch in ON position Stove turns off and will not turn on Flame is not moving Dim or poorly visible ame Log set and or ember is not glowing Flame sputters Remote control does not work 1 Reset s...

Page 10: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 11: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 12: ...fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other cost...

Reviews: