Desa BLP100 Owner'S Manual Download Page 8

102370-01K

8

For more information, visit www.desatech.com

For more information, visit www.desatech.com

FAN

1

Remove motor, motor mount, and fan (see Motor,  steps 1
through 8, page 7).

2.

Clean fan using soft cloth moistened with kerosene or solvent.

3.

Dry fan thoroughly.

4.

Replace fan on motor shaft. Make sure setscrew is touching
back of flat surface on motor shaft (see Figure 8).

5.

Place setscrew on flat of shaft. Tighten setscrew firmly (40-50
inch-pounds).

6.

Place motor, motor mount, and fan guard into rear of heater
shell (see Motor, steps 14 through 18, page 7).

Motor Shaft

Fan

Setscrew

Figure 8 - Fan, Motor Shaft, and Setscrew Location

Figure 9 - Fan Cross Section

Fan

Hub

Setscrew

Motor
Shaft

SERVICE PROCEDURES

Continued

SERVICE PROCEDURES

SPARK TRANSFORMER

1.

Remove base tray.

2.

Locate and disconnect white, black, and orange wires from
spark transformer.

3.

Remove two screws holding spark transformer to base. Re-
move sheet metal nuts on transformer and install on new trans-
former. Discard spark transformer.

4.

Install new spark transformer. Position new spark transformer
in same manner as old transformer.

5.

Connect white, black, and orange wires to new spark trans-
former. Connect wires to correct terminals as noted in step 2.

6.

Replace base tray.

Figure 10 - Removing Ignitor Wire from Spark Transformer

Bushing

Ignitor Wire

IGNITOR

1.

Remove motor, motor mount, and fan guard (see Motor, page
7, steps 1 through 6) .

2.

Remove orange ignitor wire from ignitor.

3.

Remove ignitor mounting screw from rear head using nut-driver
or standard screwdriver (see Figure 11).

4.

Remove ignitor from rear head.

5.

Install new ignitor. Attach ignitor to rear head with ignitor
mounting screw.

6.

Attach ignitor wire.

Figure 11 - Removing Ignitor Mounting Screw and Ignitor

Rear Head

Ignitor

Ignitor
Mounting
Screw

Summary of Contents for BLP100

Page 1: ...S HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER Models BLP100 REM100LP Variable 65 000 85 000 and 100 000 Btu Hr IMPORTANT Read...

Page 2: ...all local ordinances and codes In the absence of local ordinances and codes refer to the Standard for Storage and Handling of Liquefied Petroleum Gas ANSI NFPA 58 and the Propane Installation Code CA...

Page 3: ...ing items applied to heater for shipment Keep plastic cover caps attached to inlet connector and hose regu lator assembly for storage 2 Remove all items from carton 3 Check all items for shipping dama...

Page 4: ...o propane tank s Turn counterclockwise into threads on tank valve Tighten firmly using wrench IMPORTANT Tighten regulator with vent pointing down Pointing vent down pro tects regulator from weather da...

Page 5: ...imum fresh outside air ventilation requirements If proper fresh outside air ventilation is not provided carbon monoxide poison ing can occur Provide proper fresh outside air ven tilation before runnin...

Page 6: ...any ob structions 4 Replace fan See Fan page 8 5 Clean heater See Maintenance page 5 POSSIBLE CAUSE 1 No electrical power to heater 2 Fan hitting inside of heater shell 3 Fan blades bent 4 Defective m...

Page 7: ...tor mount with two nuts Tighten nuts rmly 12 Replace fan on motor shaft Make sure set screw contacts flat surface on motor shaft 13 Tighten set screw rmly 40 50 inch pounds 14 Carefully route motor wi...

Page 8: ...onnect white black and orange wires from spark transformer 3 Remove two screws holding spark transformer to base Re move sheet metal nuts on transformer and install on new trans former Discard spark t...

Page 9: ...adjustment 10 psi Maximum Tank Pressure Regulator Outlet Pressure Factory Preset Manifold Pressure 10 WC Hot Air Output CFM Approx 475 Motor 3 200 RPM 1 10 HP Electric Input 120 V 60 Hz Amperage 2 9 I...

Page 10: ...70 01K 10 For more information visit www desatech com For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN Models BLP100 and REM100LP ILLUSTRATED PARTS BREAKDOWN MODELS BLP100 REM10...

Page 11: ...rol Knob 1 18 101732 04 Thermal Switch Kit Incl Wire Assemblies 1 19 102487 01 lgnitor Electrode 1 20 097806 02 lgnitor Cable 1 21 M11084 38 Screw Hex TPG 8 18 X 38 2 22 098219 17 Power Cord 1 23 M111...

Page 12: ...6040 When calling DESA Heating Products have ready your name your address model number of your heater how heater was malfunctioning purchase date In most cases we will ask you to return the part to th...

Page 13: ...yna Glo Dura Heat Paulin Coleman Vogelzang American Other ___________________________________ 12 Who selected the product Male Female Both 13 Level of Education of Purchaser High School Vocation Techn...

Page 14: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 15: ...IN G klsuiejlb oeklhi kokle log e pdl lklsuie jlb oeklhi e pdl lklsuie jlb oeklhi kokle log e pdl l klsuiejlb oeklhi kokle log e pdl l klsuiejlb oeklhi kokle log e pdl l klsuiejlb oeklhi kokle log e p...

Page 16: ...IN LIEU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE DESA Heating Products assumes no responsibility for indirect inc...

Reviews: