H I G H P R E S S U R E P O R T A B L E F O R C E D A I R H E A T E R S E R V I C E M A N U A L
6
Heater Performance Specifications
350,000 BTU/Hr
600,000 BTU/Hr
Output Rating (BTU/Hr)
350,000
600,000
Fuel
Use only kerosene or No. 1 fuel oil
Fuel Tank Capacity (U.S. Gallons)
30
36
Fuel Consumption (Gallons Per Hour)
2.5
4
Electric Requirements
120V/60Hz
120V/60Hz
Amperage (Normal Run)
7.1
11.5
Motor RPM
1725
1725
Fuel Pump Pressure (PSI)
100
110
Spark Plug Gap
.050/.060"
.050/.060"
Weight (Approx. Lbs.)
Dry
180
285
With Full Fuel Tank
390
550
Wiring Diagrams
Wiring Diagram for Non-Terminal Block Heater with Standard Flame Control
1
2
3
RELAY
A
B
7
5
FLAME
CONTROL
WHITE
ORANGE
RED
GREEN
MOTOR
PHOTO-
CELL
BLUE
BLACK
SPARK PLUG
BLACK
BLACK
BLACK
BLACK
BLACK
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
WHITE
BLUE
FAN
SWITCH
T
R
A
N
S
F
O
R
M
E
R
ORANGE
YELLOW
YELLOW
THERMOSTAT
SOLENOID
VALVE
R
B
WHITE