background image

3

PARTS

1. Control Panel 

2. Air outlet

3. Carrying handle

4. Caster 

5. Filter frame for Evaporator Air Inlet

6. Filter frame for Condenser Air Inlet

7. Cord hanger

8. Water stopper for water tray (Dehumidifying 

water)

9. Adaptor for Exhaust pipe (exhaust pipe to be 

fixed here)

10. Water stopper    

11. Inward adaptor - for insertion over hose and 

into back of the air conditioner.

12. Outward adaptor - for insertion over hose and 

into foam strip (or into hole in the 
wall/window). 

13. Exhaust hose

14. Round cap for filling the hole in wall/window.

15. Drain tube for continuous drainage

16. Remote control (for electronic type only)

17. Foam strip - for filling the open window space 

and with hole for connection to exhaust hose.

18. Active carbon filter

Front

Back

Accessories

Downloaded from AC-Manual.com Manuals

Summary of Contents for AC 10 R

Page 1: ...Please read and retain this manual for future reference PORTABLE AIR CONDITIONER AC 10 R AC 12 R AC 12 EHP INSTRUCTION MANUAL Downloaded from AC Manual com Manuals ...

Page 2: ...r supply 220 240V 50Hz Compressor rotary Refrigerant R410a Fan speed 3 Timer 24 h Working temperature Cooling 18 32 o C Heating 5 27 o C Sleep function yes Active carbon filter yes Exhaust pipe Dia 127 x 1500 mm Net Weight 32 kg 30 kg 32 kg Dimension 482 x 380 x 750 mm 1 REMARK 1 The data marked with may vary for technical reasons for greater precision please refer to the rating label placed at th...

Page 3: ... and unplug when not in use Do not use in humid or wet environments Fig 3 Do not pull the UNIT along by the cord IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PERSON TO AVOID HAZARD Do not exceed the recommended room size Close doors and windows Keep curtains of blinds closed during the sunniest part of the day Keep filters clean Once room has reached t...

Page 4: ...rd adaptor for insertion over hose and into back of the air conditioner 12 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 13 Exhaust hose 14 Round cap for filling the hole in wall window 15 Drain tube for continuous drainage 16 Remote control for electronic type only 17 Foam strip for filling the open window space and with hole for connection to exhaust...

Page 5: ...ndow gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using the adaptor Wall or Window Outward adaptor Cut a 136mm diameter hole in the wall or window Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown When not in use plug...

Page 6: ...t to overheat and shut down Fig 11 12 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The length of the exhaust pipe is specially designed according to the specification of this product Do not replace or prolong it with your own private hose as this could cause the unit to mal function Fig 11 Fig 12 Fig 13 Fig ...

Page 7: ...frame inside the unit 1 4 2 3 OPERATION for electronic type Control panel 1 2 3 4 5 6 7 8 9 1 Button for UV or Ionizer function this is only for the model with UV or Ionizer function 2 Sleep function button 3 Timer 4 Temperature down button 5 LCD display 6 Temperature up button 7 Speed ventilation button 8 Mode function option button 9 ON OFF power button Fig 15 Fig 16 Downloaded from AC Manual co...

Page 8: ...ction indicator 11 Temperature Indicator 7 LCD Display 1 2 3 4 5 6 7 8 9 10 11 12 1 Fan Speed indicator Total 3 speed LOW MED HIGH one block means one speed 2 Auto Mode indicator Auto Cooling Auto Fan and Auto Heating function 3 Cooling Function indicator Total 3 speed LOW MED HIGH one block line is one speed When cooling function is running the block line would Flash 4 Dehumidifying Function or W...

Page 9: ... 1 Press SPEED button to choose the ventilation speed you need high medium or low The sign of high low or medium ventilation will light on at the same time 2 If the unit is in AUTO mode it will choose the ventilation speed automatically according to the ambient temperature Setting timer 1 Press TIMER button to set the operating hours you desired 1 to 24 hours the sign of timer will light on When t...

Page 10: ...turn to be LOW speed Dehumidification function In dehumidification mode the temperature cannot be adjusted the ventilation will fix at low speed Heating function This is optional only for cool heat model The air conditioner has heating function heat pump When using this function the ambient warm air is recycled and use to heat the area where it is required Under this system the machine can run at ...

Page 11: ...T function While using the heating function during low temperature sometimes the heating will stop for a while in order to melt the frost As this occurs just wait for the heating returns to work DRAINAGE During the process of cooling some water will be extracted from the air into the unit If the reservoir is full both of the compressor and motor will stop The water full sign will light on also the...

Page 12: ... the water outlet as shown and locate the other end into a drain The drain tube may be extended by adding an extension tube and using a suitable connector 11 Please note 1 The drain must be at or below the outlet level 2 Flashing Water Full indicator will not function in this mode of drainage 3 If you want to extend the water tube you can connect it with another tube OD 18mm Drain knob Rubber plug...

Page 13: ...utdoor Please refer to the instruction manual for installation method 2 Fix the drainage to be continuous one i e drain the water by water tube o o 3 Working range for heating function is 5 to 27 C for cooling function it is 18 to 32 C For temperature outside this range the unit may not work properly Water stopper Water pipe Water pipe Extended water pipe Downloaded from AC Manual com Manuals ...

Page 14: ...filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40oC Dry thoroughly before replacing Notice Never operate the unit without the filters End of season storage Drain any water in the unit before completely operating the unit on ventilation only mode for a few hours to thoroughly dry the i...

Page 15: ...taminated Is the air intake or output blocked up Is the room temperature below your selected temperature Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven Is so it is possible the overheat protection of the compressor is on Just wait for the temperature to drop The air conditioner does not run The machine seems to do little The machine seems to...

Page 16: ...provided with marking of conformity CE marking was made in 2006 Date and signature of authorized person Manufacturer s stamp DECLARATION OF CONFORMITY INFORMATION RELATED TO WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT If a device is marked with the above sign it means this electrical or electronic equipment must be collected separate from other waste materials Waste electrical and electronic equipme...

Reviews: