Se�ng up and opera�ng
PHOS rotator
31 / 56
En
gl
is
h
5.5. Se�ng up the rota�on of the mo�f
1.
Remove the housing cover (see 5.2).
2.
You can set the direc�on and speed of rota�on using
the dial below.
3.
To align the mo�f for a rigid projec�on, bring the rota-
�on to a stop with the rotary dial in the desired
posi�on.
5.6. Replacing the desiccant
Moisture that condenses in the projector head head is ab-
sorbed by the desiccant. This process can take several days.
If the desiccant is used up, replace it with a new one:
Replacing the desiccant bag in the projector head
1.
Loosen the two cylinder head screws and remove the
desiccant holder from the support rail.
2.
Remove the used desiccant bag.
3.
Carefully press the new desiccant bag into the cage so
that the two recesses for the screw heads of the lens
holder are exposed.
4.
Mount the desiccant holder with the two cylinder
head screws.
Replacing the desiccant bag in the device stand
1.
Carefully release the desiccant bag from the clip and
replace it with an unused one.
2.
Push the new desiccant bag carefully into the cage.
3.
Fit the desiccant bag holder with the cylinder head
screw to the support rail.