CONTROL MODULE INSTALLATION
ON A DUAL
SHROUD
PROCEDURE
FAN
1. With the
in
Control Module
hand, find the front two
mounting holes on controller
bracket. These holes will match
up to the
Fan
backside of the
Shroud
.
Face
2. From the backside of the shroud
slide the
into
Control Module
place and hold it.
3. On the front of shroud thread in
two
8-32 x 1/4” Allen Head
Mounting Bolts
(supplied). Using
a Allen Wrench tighten screws.
4. Place
Base into
Control Module
position on shroud, To keep the
Base in position you may need
to tape it temporarily.
5. Install the Electric fan & run the
wiring to the controller and make
connections using the correct size
connectors. Please reference
wiring instructions on page 3 and
the quick reference guide on page
5. Fan Positive (+) & Negative (-)
wires can be run through the top
of shroud, through the wire holes
of the Controller. The remaining
wires would run from the sides of
the
as shown.
Control Module
6. Position wires to avoid Control
Module Cover mounting holes
and place Cover onto the Base.
Make sure the wires are all within
the sealing foam area of cover.
Then align holes and thread-in
8-32 x 1-1/4” Allen Head Cover Bolts
using a Allen Wrench.
Note:
The above photos are only to show Control Module
Installation. Please review wiring instructions on
page
and
Wiring Diagram on page .
3
the
5
( age 2
P
)
THERMOSTAT PROBE INSTALLATION
Placement:
The Thermostat Sensor is designed to be installed on the outlet side
of the radiator, therefore sensing the cooler fluid returning to the
engine. (See Diagram #4)
Warning: Do not install the Thermostat Sensor on the Hot side
s.
of the radiator, Waterneck or Cylinder head
Installation:
1. Take the Radiator Probe and thread it clockwise onto the Thermostat Sensor.
2. Carefully insert the probe assembly into the fins of the radiator until Sensor is
flush with radiator. (Probe should not make contact with AC condenser or
auxiliary coolers. Probe may be trimmed to allow clearance.)
3. Install the Foam Pad onto the Radiator Probe.
4. Install Retaining Clip onto the Radiator Probe until tight. (See Dia. #5)
5. Route the Sensor Probe wire to the Control Module. The Sensor Wire splits
into two wires near the end. Using a Red # Ring Terminal, connect
of
8
either
the wires nto the Negative (-) Sensor Terminal on the Control Module.
o
6. Using a Red #6 Ring Terminal, connect the
Probe wire nto the
remaining
o
positive (+) Sensor Terminal on the Control Module. (See Dia. #7)
Note:
Sensor Wires are not polarity specific. Sensor Wires can be lengthened if
necessary. When lengthening wires always use good quality wire &
connections to assure proper function.
Radiator Probe
Outlet
Inlet
Down-flow Radiator
Diagram #4
Cross-flow Radiator
Radiator Probe
Inlet
Outlet
Diagram #5
Thermostat
Sensor
Foam Pad
Radiator Probe
Radiator
Retaining Clip
Outlet
CIRCUIT BREAKER MOUNTING
1. Choose a convenient location for the Circuit Breaker that is between the Fan
Controller and the Battery.
2. Using the breaker as a template, mark and drill two 5/32” holes.
3. Using the two #10 sheet metal screws supplied, secure the Circuit Breaker
in place.