5. 

MAINTENANCE SECTION  

 
 
 

 

 

 

 

Attention! 
Special  vacuum  maintenance  must  be  carried  out  solely  by  specialised  technicians 
authorised by the DEPURECO dealer. 
 

 

 

5.1 

Information notes  

 

This  section  describes  the  verifications  and  routine  maintenance  operations  required  to  ensure  proper 
vacuum operation. 
 
Maximum reliability and minimum maintenance costs are the result of a planned maintenance and inspection 
schedule carefully followed throughout the entire lifespan of the vacuum. 
Observe the set maintenance intervals and schedule the interventions according to specific requirements in 
relation with the vacuum production cycle. 
 
Always use tools that are in perfect state and that are specifically intended for the operation to be carried out; 
the use of inadequate or inefficient tools can cause serious damage. 
 
Any  other  intervention  required  to  eliminate  faults  or  malfunctions  must  be  expressly  authorised  by  the 
manufacturer. 
In these cases, always communicate the vacuum identification data - see para. 1.4 of this manual. 
 
For  important  repairs,  refer  to  the  authorised  dealer,  whose  specialised  personnel  has  the  technological 
expertise and is always available for prompt interventions. 

 
As  for  interventions  carried  out  by  the  user,  the  vacuum  must  be  disassembled,  cleaned  and  maintained, 
where  possible,  in  such  a  way  as  to  prevent  hazards  to  the  maintenance  personnel  and  to  third  parties. 
Suitable  precautions  include  decontamination  prior  to  disassembly,  forced  filtered  ventilation  of  the  room 
where  the  equipment  is  disassembled,  cleaning  the  maintenance  area  and  wearing  suitable  personal 
protective equipment.

 

 
Once  every three months  (or more frequently,  according  to  the  operating  cycle  and the  conditions  of  use), 
the  manufacturer  or  a  qualified  technician  must  check  the  filters,  ensuring  that  they  are  not  damaged  and 
must check the proper operation of the control devices.  
 
Should  maintenance  operations  or  repairs  be  carried  out,  all  contaminated  objects  must  be  adequately 
cleaned, placed in waterproof bags and disposed of in compliance with the standards in force. 
 
 
 
 
 
 

Summary of Contents for MINI BULL Series

Page 1: ...2258610357 Single document page 1 of 41 pages INSTRUCTION AND MAINTENANCE MANUAL INDUSTRIAL VACUUM SERIES MINI BULL TB This manual is an integral part of the vacuum Carefully read this manual and its...

Page 2: ...manufacture Year of manufacture to which this declaration refers complies with the essential safety requirements of the Machinery Directive 2006 42 CE Directive 2004 108 CE concerning electromagnetic...

Page 3: ...safety 11 2 2 Safety requirements 12 2 3 Safety plates and symbols 13 2 4 Residual risks 15 2 5 Applied Directives 16 3 HANDLING UNPACKING AND INSTALLATION SECTION 17 3 1 Handling 17 3 2 Unpacking 18...

Page 4: ...rnings concerning the use of the vacuum which will help fully exploiting the technical properties of your machine We recommend reading carefully the messages warnings and indications preceded by the f...

Page 5: ...of graphics text and illustrations is prohibited by law Some details shown in the figures in this manual can differ from those on your vacuum this is because some components can be removed to ensure...

Page 6: ...the main parts 1 on off commands 2 voltage and blocked filter warning lights only on Mini Bull 3 grip for handling 4 filter chamber 5 filter shaking lever 6 suction nozzle 7 collection container for...

Page 7: ...ata on the vacuum identification plate must be referred to in any communication with the manufacturer or the dealer 1 6 Intended use This model has been designed manufactured and protected solely for...

Page 8: ...e shown a sound pressure level of Mini BULL 70 TB 15 70 TB 22 70 TB 22 22 70 Attention For sound pressure levels above 85 dB A exposed workers must wear suitable personal protective equipment PPE such...

Page 9: ...voltage V 230 115 400 400 400 Power kW HP 2 4 3 2 1 5 2 2 2 3 2 2 3 Maximum negative pressure Mbar Inc 216 6 38 180 5 31 230 6 80 230 6 80 Air flow rate L min Cfm 5667 200 3334 118 3334 118 3334 118...

Page 10: ...ng of operating elements The purchase receipt must be shown to the authorised technical personnel carrying out the repair and must accompany the vacuum during its shipment Defects that are not evident...

Page 11: ...partially with the occupational safety standards and intervention procedures contained in this manual Safety warnings and precautions are indicated in this manual as well as on the product itself Ope...

Page 12: ...explosive environments Keep the vacuum clear from foreign bodies such as debris oil tools and other objects that could damage its operation and cause injuries Avoid using flammable or toxic solvents s...

Page 13: ...URECO shall not be held liable for problems caused by the use of that part Structural damage alterations or improper repairs can modify the protective capacity of the vacuum thereby nullifying this ce...

Page 14: ...ontainer in place under the vacuum Never place your hands between the vacuum and the refuse container while inserting and locking the refuse container in place under the vacuum Lock the container in p...

Page 15: ...the exceptions set forth by said Legislative Decree Risk of improper use in presence of liquid explosive and flammable substances The vacuum must not be used in environments containing liquid substanc...

Page 16: ...re to comply with this prohibition 2 5 Applied Directives The following Directives apply to the vacuum described in this manual 2006 42 CE Machinery Directive 2004 108 CE Electromagnetic Compatibility...

Page 17: ...for transporting and unpacking the vacuum correctly are shown also on the packaging The instructions below also include the operations to be carried out in the event that the vacuum must be packed or...

Page 18: ...nment in mind when lifting loads Before starting any movement ensure that the area is cleared and that there are no moving objects on the packaging For lifting and handling operations comply with the...

Page 19: ...INDUSTRIAL VACUUMS Mini BULL TB USE AND MAINTENANCE MANUAL Mini Bull TB Manual page 19 of 41 pages remove the carton loosen and remove the fastening screws and brackets from both sides...

Page 20: ...t using the same fastening system 3 3 Installation Warning Before installing the vacuum it is important to carry out a thorough preventive visual inspection to identify any damage occurred during tran...

Page 21: ...arious types of OPTIONAL that can be used on this specific model The following operation must be carried out by a qualified electrician Ensure that the power supply line corresponds to the voltage and...

Page 22: ...out interventions on the vacuum must be adequately educated informed and trained in compliance with the occupational safety standards in force and during the various operations must wear personal prot...

Page 23: ...te Attention Before inserting the plug ensure that the voltage of the power supply line corresponds to that indicated on the vacuum s identification plate Ensure that the power plug is inserted correc...

Page 24: ...eater suction power the second motor can be turned on by pressing the other switch To turn off the vacuum press the switches previously turned on For the TB model Turn the main switch 2 to I and start...

Page 25: ...of negative pressure inside the vacuum The vacuum gauge indicates the condition of the filter negative pressure increases indicate filter clogging with consequent reduction of the suction power When t...

Page 26: ...rly after having cleaned the filter it can mean that the filter is clogged and needs to be replaced 4 3 Emptying the refuse container Attention Wear PPE gloves dust mask goggles etc during this operat...

Page 27: ...ull TB Manual page 27 of 41 pages unlock the container by lifting the lever remove the container from the vacuum using the handle empty the vacuum container in the dedicated container and dispose of i...

Page 28: ...with the standards in force in the country of use for Italy with Legislative Decree 152 2006 and subsequent amendments and additions In the event of use with class M and H dusts these must be conveye...

Page 29: ...circumstance place your hands between the container and the vacuum while locking it 4 5 Storage decommissioning Remove the filter and clean it empty the refuse collection container and store the vacu...

Page 30: ...xpressly authorised by the manufacturer In these cases always communicate the vacuum identification data see para 1 4 of this manual For important repairs refer to the authorised dealer whose speciali...

Page 31: ...d out by trained technicians specialised in the following sectors Mechanical maintenance Electrical maintenance It is the Safety Manager s duty to ensure the professionalism and skills of these techni...

Page 32: ...l maintenance technician authorised by the Safety Manager Attention After every maintenance operation the Safety Manager is obliged to ensure the safety conditions of the vacuum and its protection dev...

Page 33: ...the filter proceed as follows turn off the machine disconnect the vacuum from electric power supply remove the container as described at point 4 3 from the bottom of the filter chamber release the cli...

Page 34: ...l TB Manual page 34 of 41 pages unlock the two locking hooks from both sides of the base of the head on the filter chamber remove the head with its base remove the HEPA filter following the procedure...

Page 35: ...er insert the filter into its support ring locking it by means of the fastening clamp H lock the filter to the cage tying the wires on its lower side insert the filter complete with ring and cage into...

Page 36: ...e periodically verified relative to the filtering ability Attention To replace the HEPA filter wear appropriate PPE dust mask protective goggles latex gloves etc To replace the HEPA filter remove the...

Page 37: ...cuit breaker tripped TB Check that there is voltage in the socket Check the electric plug and power cord Reset the circuit breaker TB Contact the DEPURECO technical service centre The vacuum gauge ind...

Page 38: ...force for Italy Legislative Decree 152 2006 and subsequent amendments and additions Before scrapping the machine the plastic and rubber materials must be separated from the electrical material Correct...

Page 39: ...he warranty copy this form fill it all in possibly in block capital letters and fax it to the manufacturer at the following number 0 1 1 9 8 5 9 3 2 6 or DEPURECO DEPURECO com VACUUM COMPONENTS Model...

Page 40: ...TB USE AND MAINTENANCE MANUAL Mini Bull TB Manual page 40 of 41 pages MAINTENANCE LOG INTERVENTION 1 Date Technical Assistance Type of intervention Signature INTERVENTION 2 Date Technical Assistance T...

Page 41: ...TB USE AND MAINTENANCE MANUAL Mini Bull TB Manual page 41 of 41 pages MAINTENANCE LOG INTERVENTION 3 Date Technical Assistance Type of intervention Signature INTERVENTION 4 Date Technical Assistance T...

Reviews: