background image

4. Setting up WI-FI connection to the Micro 
inverter. 

 

Do not insert Schuko power plug into the Schuko power outlet yet.

 

 

Step 1 

After the cabling has been completed as described in previous chapter the LED light on the micro inverter 
flashes red every 1 second.  

Please notice that the LED can be difficult to see in full sunlight. Hold your hand to the LED to create some 
shade and then you should be able to see it. 

 

 

The LED light indicator 

 

 

 

 

 

Summary of Contents for BSS-10600

Page 1: ...User guide for installing the Balcony solar system facebook com denver eu Please read this guide before installing the product Keep the assembly instructions for future reference ...

Page 2: ... improper handling Failure to do so can result in serious health consequences such as electric shocks and other life threatening injuries Please keep the assembly instructions for future reference 1 This product is not a toy Keep it out of reach of children 2 Keep product out of the reach of children and pets to avoid chewing and swallowing 3 This device is not intended to be used by persons inclu...

Page 3: ...orms A licensed electrician can help you with this This is not included 9 Repairs and maintenance may only be carried out by qualified personnel Never open the product and make repair yourself Do not open the electronic devices This can lead to serious security problems health hazards or equipment damage Also warranty is void if doing so 10 Do not make modifications to any components of the PV mod...

Page 4: ...e be sure to read the manual and follow the instructions and safety information in it SAFETY WARNING Cleaning activities create risk of damaging the modules and array components as well as increasing the potential electric shock hazard Cracked or broken modules represent an electric shock hazard due to leakage currents and the risk of shock is increased when modules are wet Before cleaning thoroug...

Page 5: ...ash with water and a non abrasive cleaning implement sponge during the cool part of the day Do not scrape or rub dry dirt away as this may cause micro scratches 16 Periodically inspect the system to check the integrity of all wiring and support Turn off power before doing this Also periodically check that the bolts for mounting the solar panels are fastened and not loose 17 Cracked or broken modul...

Page 6: ...2 The Balcony solar system in overview 1 2 pcs solar panels 2 Micro inverter 3 This plug connector should not be used 4 This plug connector is be connected to the Schuko power cable 5 Schuko power cable ...

Page 7: ... each of the solar panels according to the bracket installation guide Please note that not all models come with included bracket During the installation process please handle the solar panels with care to avoid bumping or scratching the solar panel If the solar panel needs to be placed facing the ground temporarily please take protective measures Do not put weight on top of the panel The panel can...

Page 8: ... bracket Make sure that the inverter is properly fixed to the bracket The micro inverter can also be installed on other firm and light proof shade location as needed But please make sure to keep it away from flammable material and direct sunlight The inverter needs to be installed as close to the inverter as possible so the solar panel MC4 plugs can reach the micro inverter ...

Page 9: ...Note Please make sure that the power is disconnected before plugging or unplugging the panels modules from the inverter Do not insert Schuko power plug into the Schuko power outlet yet Insert the 2 pairs of MC4 plug cables from the 2 solar panels into the MC4 connectors on the micro inverter Please notice the polarity of the MC4 plugs ...

Page 10: ...Solar panel MC4 plugs Also please notice that the plugs should be inserted in sets pairs like below Do not mix one solar panel connectors between set 1 and 2 ...

Page 11: ... Step 1 After the cabling has been completed as described in previous chapter the LED light on the micro inverter flashes red every 1 second Please notice that the LED can be difficult to see in full sunlight Hold your hand to the LED to create some shade and then you should be able to see it The LED light indicator ...

Page 12: ...ith Wi Fi and connect this to the wifi network SSID NEP xxxxxxxx The xxxxxxxx refers to the micro inverters unique ID number sticker which can be found on the micro inverter Connect to the NEP Wi Fi device Enter password 12345678 and press next to connect to the micro inverter ...

Page 13: ...icro inverter is connected to the PC Now there is Wi Fi connection between the micro inverter and you PC via Wi Fi But you still haven t got the micro inverter on you home Wi Fi network So this is the next step ...

Page 14: ...54 Now you are asked for a username and a password Enter admin both places and press OK You have now access to the Micro Inverters Wi Fi settings Press the search button and choose your Wi Fi network and press OK Enter your Wi Fi password key and press OK ...

Page 15: ...es After restart the Inverter should be connected to the Wi Fi Connect the Schuko power plug to the power outlet of the house apartment and you can turn on the power Now the solar system should be up and running After 10 minutes LED flashes green every 3 seconds ...

Page 16: ...APP then you need to register your solar system Please wait 10 15 min with this task after inserting the Schuko power plug info the power outlet Visit NEPViewer website https user nepviewer com Press Register button and follow the instructions and login Please note down the password for later use ...

Page 17: ...You now get the User Registration menu 1 Enter email address 2 Enter password 3 Confirm password 4 Enter Street 5 Enter City 6 Select Country ...

Page 18: ...7 Select State Province 8 Enter Zipcode 9 Enter contact person 10 Enter contact number optional Press save Now you enter the main menu ...

Page 19: ... address 2 Enter your country 3 Choose you state province 4 Enter your city 5 Enter street 6 Choose BDM WIFI 7 In the Micro Address menu point you enter the Unique inverter barcode you find on the inverter Do not use below as it is just an example Press Next and a new menu appears ...

Page 20: ...1 Enter the name of the plant You can freely choose 2 This is automatically filled out 3 This is automatically filled out 4 Choose your Timezone ...

Page 21: ...f your solar panel if you like It is not a must 7 Leave this empty Press create button After registering then you can download the NEPViewer APP from Google Playstore Apple APP store When installed you will see this this Login screen Insert the same email and password used for registering previously on NEPViewer homepage from your computer ...

Page 22: ...Now you will see this screen and you can follow your energy production from your phone or tablet Congratulations you are now producing you own green power ...

Page 23: ...fies that electric and electronic equipment should not be disposed of with other household waste but should be disposed of separately All cities have established collection points where electric and electronic equipment can either be submitted free of charge at recycling stations and other collection sites or be collected from the households Additional information is available at the technical dep...

Page 24: ...ther downloads Operating Frequency Range 2401 to 2484 MHz Max Output Power 19 dBm DENVER A S Omega 5A Soeften DK 8382 Hinnerup Denmark www facebook com denver eu service support info Denver Germany GmbH Service Max Emanuel Str 4 94036 Passau Support de denver eu Tel 49 851 379 369 40 ...

Reviews: