Midwest Air Repair

Service

Should your Midwest Stylus High Speed Handpiece need repair,
call 

1-800-800-7202

to schedule a free pick-up:

Air Repair offers:
• Repairs DOOR TO DOOR ROUNDTRIP IN 2 BUSINESS DAYS
• Genuine Midwest Parts and Midwest Quality
• Expert Troubleshooting and Diagnosis
• Repair Service Warranty equal to the new product warranty

For Customers Outside the United States,
Contact Your DENTSPLY Representative.

Send to:

DENTSPLY Professional Division
Midwest Dental Products

Attn: Midwest Air Repair  
901 West Oakton Street  
Des Plaines, IL  60018-1884

Provide the following infomation with your repair:

Your complete name and address
Dealer name and address
Nature of repair

Repair — Within the United States

11

Summary of Contents for MIDWEST Stylus 180S Series

Page 1: ...Stylus Standard MIDWEST 180S 181S 360S 361S 540S 541S High Speed Handpiece with Fiber Optics Push Button Chuck...

Page 2: ......

Page 3: ...Midwest Stylus Standard 180S 181S 360S 361S 540S 541S High Speed Handpiece with Fiber Optics and Push Button Chuck Installation Maintenance and Operation Instructions 1...

Page 4: ...care Professional DHCP to understand the intended uses of this product the health of each patient the dental procedures being undertaken and industry and governmental agency recommendations requiremen...

Page 5: ...or 180S 360S 540S series and 42 psi 2 9 Atm for 181S 361S 541S series Air pressure should be measured at the handpiece end of the hose Have your dealer or serviceman use an analyzer gauge Connect gaug...

Page 6: ...andpiece To disconnect push both buttons at the base of coupler and remove handpiece Coupler remains installed on the hose NOTE Do not attempt to remove handpiece from coupler without pushing buttons...

Page 7: ...highly recommended that all dental water supply systems conform to applicable CDC Centers for Disease Control and Prevention and ADA American Dental Association standards and that all recommendations...

Page 8: ...fiber optic light port near head of handpiece is scrubbed well Once a week or as needed gently rub an alcohol soaked cotton swab against both ends of the fiber optic element to remove debris DENTSPLY...

Page 9: ...dry gauze pad or paper towel 3 On a weekly basis or if button gets stiff spray Midwest Plus Aerosol Spray into chuck for one second NOTES A KaVo MULTIflex lubricating nozzle will conveniently fit ont...

Page 10: ...temperature of 135 C 275 F Keep handpiece in bag until ready to use in the operatory Insert the coupler into the handpiece until it clicks into place Check for secure connection by tugging the handpi...

Page 11: ...181S 361S 541S series 5 With a loose or bent bur 6 If you experience a sudden and noticeable change in handpiece noise or vibration 7 If bur moves forward more than 1 mm while operating handpiece Reco...

Page 12: ...ting instruments up to 906 inches 23 mm long You can fine tune the water spray by adjusting the chip air on your unit WARNING Use of cutting instruments over 906 inches 23 mm in length could possibly...

Page 13: ...ubleshooting and Diagnosis Repair Service Warranty equal to the new product warranty For Customers Outside the United States Contact Your DENTSPLY Representative Send to DENTSPLY Professional Division...

Page 14: ...or use with Air Station 380090 Midwest Spray Guards Box of 100 380150 Cleaning Wire for all Midwest Stylus Handpieces 464197 Parts REF Parts REF Replacement o rings 5 Hole Coupler 2 sets 790255 Replac...

Page 15: ...our Midwest Stylus handpiece is guaranteed to be free of defects in materials and workmanship for a period of five 5 years from date of purchase provided that the handpiece has been operated and maint...

Page 16: ...ENTSPLY DeTrey GmbH DENTSPLY Canada De Trey Strasse 1 161 Vinyl Court D 78467 Konstanz Germany Woodbridge Ontario L4L4A3 800 263 1437 FM 72416 Operating a quality system which complies with the requir...

Reviews: