![Denso QS20P-A User Manual Download Page 21](http://html1.mh-extra.com/html/denso/qs20p-a/qs20p-a_user-manual_2483243021.webp)
9
Chapter 6. Parameters and Defaults
The table below lists the parameters and their default values. Note that the
defaults given below are values preset when the QS20P-A leaves the factory.
Some of the communications parameters and reading mode settings may have
been modified by dealers according to your needs.
You may change parameters given in the table below by using the QR-coded
parameter menu given in Chapter 7.
Parameter group
Parameters
Function
Factory defaults
Communications
Non-acknowledge mode
√
procedure
ACK/NAK mode
Communications
CTS control
Enabled
conditions
Disabled
√
Transmission rate
4800 bps
9600 bps
19200 bps
38400 bps
√
57600 bps
115200 bps
Character length
8 bits
√
7 bits
Parity check
No
√
Even parity
Odd parity
Stop bit length
1 bit
√
2 bits
Transmission
Header
None
√
format
STX
Terminator
ETX
CR
√
LF
CR LF
Transmission of code
Disabled
√
ID mark (see p. 15)
Enabled
Transmission of no.
Disabled
√
of digits
Enabled
Transmission of
Disabled
√
BCC (Note 1)
Enabled
(Note 1: BCC is disabled automatically if no header is selected.)