- 14 -
GetSignalStrength
Get the signal strength.
■
Syntax
[VB]
Public
Shared
Function
GetSignalStrength
( _
ByRef
RSSI As
UInt32, ByRef
BER As
UInt32
) As
UInt32
[C#]
public static UInt32
GetSignalStrength
(
out UInt32
RSSI,
out UInt32
BER);
■
Parameters
RSSI
[out] signal strength
rssi
specification
0
-113 dBm or less
1 -111
dBm
2…30 -109…-53
dBm
31
-51 dBm or greater
99
Not known or not detectable
BER
[in ] Bit Error Rate
■
Return value
error code
0 : Normal end
Other than 0 : Abnormal end. For more detail, refer to 7. error code.