background image

 

 

 

 

13 

1) Operation of the Deck A/B Selector 

(1)  Press the RESET button to reset the counter to "0000". 
(2)  By using the PLAY, FF, or REW functions, the reading of the 
 

counter will change to indicate index position. 

•  During recording and playback operations, the counter is useful for noting the 

location of existing programs or positions where recording is to be started. 

•  The reading of this counter does not correspond with that of any other deck. 

(3)  Deck A and Deck B have the memory of their own counter. Operate COUNTER A/B 

to change Deck A or B to display its counter. 

(4)  The level meter and Dolby setting display also switch with the 
 

Deck A/B selector. 

 
 

2) MEMORY STOP Operation 

(1)  During recording or playback, the Memory Stop feature can be used to locate a 

particular point on the tape. Press the COUNTER MEMO button at the desired 
point. 

(2) 

The MEMO indicator lights. 

(3)  When the Rewind 

(

<<

is pressed during forward tape travel (

), or the Fast 

Forward (

>>

) button is pressed during reverse tape travel (

), the tape is 

rapidly rewound (or advanced) until the counter indication of "0000" is reached. 

• 

The Memory Stop feature will rewind or forward the tape to within -5 counts in 
the forward (

) direction (from "0000" to "-0005") and to 5 counts in 

the reverse (

) direction (from "0000" to "0005"). After this, several seconds 

are required for corrective operations. 

• 

The Memory Stop function operates independently in both directions for deck A 
and deck B. The MEMO indicator will switch over with the use of the DECK A/B 
button. 

 

Caution: 

If the memory stop operation is performed after repeated fast 
forwarding or rewinding, the tape may not stop at the proper position. 

(3)   Display Back-up 

(1) 

The COUNTER VALUE, DECK A/B, MEMO DIRECTION and DOLBY NR functions are 
protected for approximately one month by a memory back-up. 
Once the back-up period is up, the DOLBY NR and MEMO settings are set to off, 
the DECK A/B setting is reset to "A" the DIRECTION setting is set to (

), and 

the counter is reset to "0000". 

DECK A / B SELECT AND MEMORY STOP 

Summary of Contents for DN-770R

Page 1: ...STEREO CASSETTE TAPE DECK DN 770R OPERATING INSTRUCTIONS...

Page 2: ...serial number of your set shown on the rating label Model No DN 770R Serial No CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICIN...

Page 3: ...ot likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience receptacles and the point where they exit from the appliance 14 Clea...

Page 4: ...g the cord Keep the set free from moisture water and dust Unplug the power cord when not using the set for long periods of time For sets with ventilation holes Do not obstruct the ventilation holes Do...

Page 5: ...X Pro Headroom Extension System deck B only Dolby B C Noise Reduction Systems A B Independent Computing Tape Counter with 4 Digit Readout and Memory Stop Music Search System FL Peak Level Meters Auto...

Page 6: ...deck A only regardless of the position of the deck A B selector Reverse Mode Switch REV MODE Select the type of tape transport The reverse mode can be set to one side continuous playback RELAY relay...

Page 7: ...nding button is pressed CASSETTE TAPES Handling Precautions C 120 Cassettes C 120 cassette tapes are not recommended as they use a very thin tape base which may become tangled around the capstan or pi...

Page 8: ...r When listening to a tape that has been recorded with Dolby noise reduction set the DOLBY NR button to match the system used at the time of recording Pressing the DOLBY NR button selects Dolby noise...

Page 9: ...rdings with discontinuous speech or conversation Recordings with long periods of pianissimo softly played music Recordings with long silences Blank sections with a high level of noise Blank sections s...

Page 10: ...er Press the PLAY button to start the recording The PLAY or and the indicator will light during recording To stop recording press the stop button To pause the recording press the REC PAUSE II button P...

Page 11: ...B and the REVERSE MODE switch Press the TWIN REC button The A B indicator will light up and both decks will enter the recording pause mode Adjust the INPUT LEVEL control for the best recording input...

Page 12: ...ortion of the opposite side of the tape To begin normal speed dubbing press the DUBBING SPEED NORMAL button The DUB indicator will light at this time To high speed dubbing press the DUBBING SPEED HIGH...

Page 13: ...g forward tape travel or the Fast Forward button is pressed during reverse tape travel the tape is rapidly rewound or advanced until the counter indication of 0000 is reached The Memory Stop feature w...

Page 14: ...ned more often to enjoy the best possible sound 14 The operating principle of Dolby C NR is similar to that of Dolby B NR except for the encoding decoding response curves The noise reduction effect ob...

Page 15: ...ape is worn Replace tape The cassette tape cannot be removed If the POWER switch is turned off either Turn the POWER switch ON again and during recording or playback and the unit is then press the STO...

Page 16: ...ptible the system will be to the effects of external noise Keep cable lengths to 2 m or less Do not locate equipment that produces electrical noise in the vicinity of the cable Doing so might lead to...