Fasstransporter DT250 /Fasslifter RT250
Seite 9 von 10 Seiten
Ausgabe 07/2012
164380 / 164387, 180867, 180868
7.1 Removing air bubbles / checking the oil level
To remove the air from the system or to check the oil level the lifting carriage has to be taken off the hydraulic unit.
Open the relief valve (6).
Loosen the retaining rings and then remove the bolts and rollers.
When you have then lifted up the lifting
carriage you can see the oil filler screw.
When you unscrew the screw you remove the air from the system.
Check the oil level. The oil should be up to the lower edge of the bore.
If applicable refill the oil in accordance with ISO VG 46 and then screw in the screw hand-tight.
8. Declaration of conformity
EC Declaration of Conformity
Herewith we, the DENIOS AG, Dehmer Straße 58-66, D 32549 Bad Oeynhausen, declare that the product
complies with following guidelines.
Type:
DT drum transporter./.RT drum lifter
Safe working load:
250 kg
EC Directives
Machinery directive 2006/42/EC
Harmonised standards applied
EN 349
EN 1757-2
EN EN ISO 12100
EN ISO13857
Person responsible for documentation
DENIOS AG, 17.07.2012
Mr. Dr. Ing. R. Adenstedt
Benedikt Boucke
Head of engineering
- Board of governors -