bio.x B200
Page 3 of 12
01/2010
1. Safety instructions
This unit can only be used safely if you read this user manual carefully and strictly follow the instruc-
tions it contains.
The equipment must be set up on a suitable stable, level surface.
Please note the application- and warning messages on the label of the detergend. wrong use could
cause damage to material and health.
Contact to the detergend could cause skin irritation. when operate the system please always ware
safety gloves, safety glasses and protective clothing.
Please professional dispose used detergend
The mains supply connection has to be in accordance with the corresponding regulations (VDE 0100 - As-
sociation of German Electricians). For safety reasons the equipment must be only operated, if a Residual
Current protective Device (RCD) with a release current of 30 mA is connected upstream.
This must be checked by a qualified electrician.
In accordance with the German BGV A3 electrical equipment has to be examined in regular inter-
vals.
Detergents which contain highly flammable substances must not be used. Use only detergents ap-
proved by DENIOS for this unit.
2. Technical data
Dimensions
890 x 750 x 1155 mm
Net weight
45 kg
Power consumption
max. 660 W
Electrical connection
1/N/PE 230V
∼
, protection category 1
Pre-fusing 10
A
Work surface height
950 mm
Load capacity
100 kg
Tank LDPE
Maximum fill capacity
approx. 80 l
Minimum fill capacity
40 l
Usable work surface
760 x 560 mm
Heater
600 W
Level switch
Minimum fill level (approx. 40 l)
Operating temperature
Set at 41°C in the factory
Pump, flow rate
4l/min
172236, 172292, 176074