4. Press the TIMER button. The time (XX min) at the top right of the screen will flashing
and you can use the – and + buttons to set your countdown timer.
5. Once the TEMP, POWER and TIMER have been set, press the START/STOP button to
start the machine. The H – symbol at the top left of the screen will flash to show that
the machine is heating. The machine will then heat the liquid up to your temperature
set-point. Once it reaches the set-point, the machine will chime and start the count-
down timer while maintaining the set-point temperature. The time will flash while the
timer is counting down.
Note: The H – symbol will continue flashing even when the elements are off. Once the
timer reaches zero, the machine will chime and the word END will flash on the screen.
Press the START/STOP button to stop the chime.
6. To edit any of the TEMP, POWER or TIMER settings, press the MANUAL/PAUSE
button again. To return to your program after adjusting any of the settings, press the
MANUAL/PAUSE button again
7. The default boiling temperature is 100℃. The timer will not be triggered if temperature does
not indicate 100℃.
8. If the machine starts to boil, but shows a lower temp on the display (i.e. if you are brewing
at a higher altitude than sea level), make the following adjustment to set the temp at 100℃ and
trigger the timer.
9. Press START/STOP until only the temperature is displayed on the screen. Press “-” and “+”
button together for 5 seconds and then release, the display will show the C1 (temperature
offset for celsius) or F1 (temperature offset for fahrenheit). Press the MANUAL/PAUSE button
until the display shows C2 (boil temperature offset for celsius) or F1 (boil temperature offset
for fahrenheit).Temperature correction range is from 0℃ to +10℃ or 0℃ to +50℃. If you set C2 to 6℃
then the unit will begin the boiling stage of the program at 94℃.
8. Press MANUAL/PAUSE button during heating to go back to the edit page. You can edit
Temp/Power/Timer, then press the MANUAL/PAUSE button again to resume.
NOTE: Long press TEMP for 5 seconds, switch degree centigrade to Fahrenheit.
This operation only can be preceded when you switch on the machine before any setting.
9.